AMX RE-DM6, RE-DM4 manual Programming Commands, Control Curves and Low-End Settings

Page 42

AMX RADIA Lighting Programming

Programming Commands

The AMX Lighting system uses four main types of programming commands: Setup, Recording, Status, and Operation commands. The following description applies to the AxLink Command Structure.

Setup commands

These types of commands are global commands sent to Pack #1 that affect the entire network.

These commands are used to set the default values and parameters that are typically entered at the startup of the system and not changed. If certain commands are issued with a time value associated then the AMX Lighting system will use an available default value determined at setup.

The commands for recording and recalling presets use these defaults, as do ramping operations. Curve settings are setup commands done on a individual channel basis and are not global.

Curves are set in the beginning and do not need to be changed unless the loads also change.

Recording commands

These commands send preset data to the AMX Lighting memory chip. All recording and setup commands are stored in non-volatile memory. These commands are also used to store presets, assign presets for dry closure recall, and erase stored presets.

Status commands

Status commands allow a user or a program to get data from the lighting system and act on that information. This feature gives a computer the ability to perform interactive processes with the AMX Lighting system.

Operation commands

The operational commands category, the largest category used by the AMX Lighting system, is used for real- time lighting control and setup of scenes prior to programming presets. Operational commands recall, ramp, and set levels for dimmers. They can also be used for remote operation of the dry closure contact.

Control Curves and Low-End Settings

The market currently has a great selection of new lamp and ballast options. Each one has properties and dimming characteristics that present a new challenge for the dimmer manufacturer to provide an appropriate dimmer. What was designed as a standard incandescent dimmer must now be able to control electronic ballast, incandescent lamps, low voltage track lighting, and a host of new transformers. One way to solve many of these problems is to apply different control curves to each dimmer and to provide a variable low-end cut-off point.

A dimming curve is a graphical or electronic representation of the amount of control that must be applied to a dimmer in relation to the dimmer output. This is much like a directional map that the controller follows. The amount of control is typically measured in percent; from an Off-state of level 0 to an On-state at level 100.

Dimmer output is measured in volts. A graphical representation of a dimming curve is usually the percentage of dimming in relation to the output voltage (RMS) of the dimmer connected to a standard load. FIG. 37 shows a sample dimming curve.

FIG. 37 Sample dimming curve

Sometimes a fixture or lamp has a problem dimming down to a low range. When this happens, the lights can flicker and cause unwanted dimming performance.

34

RE-DM4 and RE-DM6 RADIA Eclipse Dimmer Modules

Image 42
Contents Radia Eclipse Dimmer Modules AMX Limited Warranty and Disclaimer Page Page Table of Contents Radia Lighting System Configuration Pages Initial Level Status Reporting Appendix a AMX Lighting Curves Overview Radia Eclipse RE-DM4 Dimmer ModuleDimmed Switched RE-DM4 SpecificationsRE-DM4 Specifications Suggested LoadsRE-DM4 4-pin module connector male Line-In ConnectionsRE-DM4 Lighting Application Drawings Lighting Application for the RE-DM4, Example aRadia Eclipse RE-DM6 Dimmer Module RE-DM6 6-channel Integrated Dimmer ModuleRE-DM6 Specifications Suggested Installation LoadsRE-DM6 Specifications Line-In Connections for the RE-DM6 RE-DM6 Lighting Application Drawings Lighting Application for the RE-DM6, Method aAMX Lighting Control Equipment FeaturesApplications AMX Lighting Control EquipmentDimmer Accessories Integrated dimmer control modulesDimmer modules Wiring Considerations Power considerationsSpace Requirements Conduit Knockout locations RDA-ENC2 used as exampleRDA Enclosure Dimensions RDA-ENC2, -ENC4, and -ENC6 enclosure and dimensionsRDA-ENC6B and RDA-ENC12B enclosures and dimensions Mounting AMX Lighting Enclosures Distance a to BConnecting High-Voltage, Single-Phase Input Power and Loads High-Voltage ConnectionsRDA-ENC6B 120 VAC Single Phase Line Input RDA-ENC6B 120/240 VAC Line Input Single PhaseConnecting High-Voltage Input Power and Loads RDA-ENC6B 120/208 VAC line input three phase RDA-ENC6B 120/208 VAC three-phase 4 W + G wiring diagramRDA-ENC6B Three Phase Line Input Connector Reference RDC-PFC Power Distribution And Line Input ReferencesInstalling RDM Modules Into an RDA Enclosure Enclosure module mounting slots and mounting screw holesGreen LED Status Indicator Low-Voltage ConnectionsModule Connections Red LED Status Indicators RE-DM4 only Configuring and connecting multiple controllersConfiguring and Connecting AxLink SW1 DIP Switch Setting Values for AxLinkValue Dry Closures External powerConnecting Dry Closures Failsafe InputDefault preset time values Default SettingsDefault Low-End Settings Default PresetsRadia Lighting System Configuration Pages Lighting System LinkRadia Configuration Manager Main Lighting SystemDevice Configuration Device ConfigurationPresets section Preset Configuration Radia Lighting System Configuration Pages AMX Radia Lighting Programming SoftwarePresets Defined vs. Undefined Levels Preset StatusPreset # Lighting Systems Overview Sample AMX Lighting controller and internal componentsProgramming Commands Control Curves and Low-End SettingsDefault Ramp Time Default Low-endDefault Ramp Time LevelsSENDSTRINGs AMX Lighting Channel CommandsChannels Protocol ConventionsRamp Dimmers Up Ramp Dimmers UpRamp Dimmers Down Ramp Dimmers DownRamp Active Preset Up Ramp Active Preset DownStop Ramping Dimmer Record Preset Stop Ramping PresetRecall Preset Level StatusSet Low End Set CurveCurve Status Low End StatusSet Default Preset Time RebootSet Default Level Time Dimmer StatusSet Default Ramp Time Ramp To LevelUndefine Dimmer Phase Query Factory DefaultVersion Query Sendcommand Protocol Conventions SENDCOMMANDsRamp Preset Up NEW Ramp Preset UpRamp Preset Down NEW Stop Ramping Preset NEWRamp Preset Down Set Low End NEW Reboot NEWCurve Status NEW Low End Status NEWUndefine Dimmer NEW Phase Query NEW Sendcommand Radia,?YAppendix a AMX Lighting Curves Basic dimming curve Curve Configuration CurvesCurves Standard Dimming Curve Load Type CurvesCurve 1 Voltage Output in 240V AC Curve 1 with Low End Setting @ 5%, 10%, and 20% Volts RMS Economical Dimming Curve10VDC Curve Curve 2 at 240 VACCurve 3 at 120 VAC 12VDC Curve Curve 4 Voltage output in Volts RMSLutron FDB Curve Curve 4 Voltage output in volts DCCurve 5 at 240 VAC Advance Mark VII Curve Curve 6 Voltage output in Volts RMS12% Roll Off Curve 6 Voltage output in volts DCCurve 7 Voltage output in Volts RMS 19% Roll Off Curve 8 at 120 VAC33% Roll Off Curve 8 Voltage output in volts DCCurve 9 Voltage output in Volts RMS Curve #1 a Curve a at 120 VACLog-Curve #1 B Curve a Voltage output in volts DCCurve B Voltage output in Volts RMS Log-Curve #2 C Curve C at 120 VACCurve #2 D Curve C Voltage output in Volts DC10% Off Curve N Curve D Voltage output in Volts RMSAlways OFF Curve O Curve N at 240 VACAlways on Curve F Curve O at 240 VACCurve F at 240 VAC Curve R at 120 VAC Curves 5 & B on the Radia Eclipse RE-DM6 at 120 VAC Curves a & D at 120 VAC Page Testing AMX Lighting features Software IssuesUsing Pass mode Testing procedures for AMX Lighting featuresHardware Checklist Hardware IssuesTroubleshooting hardware To check thisPage Increase Your Revenue through education + knowledge
Related manuals
Manual 2 pages 38.75 Kb Manual 2 pages 7.17 Kb

RE-DM4, RE-DM6 specifications

The AMX RE-DM4 is a cutting-edge solution in the realm of digital media management, designed to cater to the complexities of modern broadcasting environments. This advanced device aims to streamline workflows, enhance media asset management, and ensure optimal media delivery across various platforms.

One of the standout features of the AMX RE-DM4 is its robust interface, which allows users to interact with the system intuitively. The device incorporates a user-friendly GUI that enables operators to manage media assets effortlessly. The interface supports drag-and-drop functionalities, which greatly simplifies the process of uploading, organizing, and retrieving digital content.

The AMX RE-DM4 also boasts innovative multimedia processing capabilities, allowing it to handle high-resolution video formats with ease. The device supports a range of codecs, ensuring compatibility with the latest video and audio standards. This versatility is crucial for broadcasters who frequently work with diverse media types and formats.

Furthermore, the AMX RE-DM4 features advanced metadata tagging and search functionalities. This technology empowers users to tag media assets with critical information, enabling quick retrieval and efficient categorization. The integrated search engine is designed to facilitate instant searches, thereby reducing downtime and improving overall productivity.

Another notable characteristic of the AMX RE-DM4 is its scalability. The system is designed to grow alongside evolving media requirements, making it an ideal choice for both small studios and large broadcasting networks. With modular components and expandable storage options, users can easily upgrade their systems as their needs change.

In terms of connectivity, the AMX RE-DM4 includes multiple input and output options, ensuring seamless integration with existing studio equipment and networks. It supports various protocols, which enhances compatibility with other devices and allows for more fluid media workflows.

Security is a crucial aspect of digital media management, and the AMX RE-DM4 addresses this by incorporating robust encryption and access control features. Users can set permissions for different team members, safeguarding sensitive content while still allowing collaborative work environments.

In conclusion, the AMX RE-DM4 emerges as a powerful tool for media professionals, integrating state-of-the-art technologies and features that enhance efficiency and productivity. Its intuitive interface, multimedia processing capabilities, advanced search options, scalability, and robust security measures make it a valuable asset in the fast-paced world of digital media management. This device exemplifies a forward-thinking approach to media handling, positioning itself as a leader in the industry.