Omega Speaker Systems OS533E, OS532E, OS524E, OS530LE, OS53xE-CF manual Reviewing the Last Parameters

Page 47

2Using the Handheld Infrared Thermometer

2.4.1Reviewing the Last Parameters

°F

The thermometer stores the last temperature measured in the real time mode (refer to Table 2-1). This temperature can be recalled by pressing the FUNC key.

-Press the FUNC key to review the most recently stored temperature data and parameters. You may review:

MAX temperature

MIN temperature

• dIF temperature

 

Calculated values

 

AVG temperature

TC temperature

HAL temperature

• LAL temperature

Set values

 

AMB temperature

MEM location

2.4.2Reviewing Previously Stored Temperature Data (OS534E, OS523E, OS524E)

°F

You can review all 800 stored temperature values on the thermometer display using the following procedure:

1.Press and hold the FUNC key until you see the Memory Display Mode (MEM) appear.

2.Press the key to increment the memory location or press the C F key to decrement the memory location. The memory location can be from 001 to 800.

3.Press the LOCK key. The stored temperature is shown in the lower portion of the display. If there is no data stored in a memory location, the display shows “----”.

NOTE

If no keys are pressed, the thermometer goes into sleep mode in approximately 5 seconds.

2-32

Image 47
Contents User’s Guide Servicing North America Unpacking Instructions Accessories Page Unpacking Instructions Chapter General Description Chapter Digital Video Camera General Description Introduction OS530LE OS530HRE OS530LE-CF OS533E-CF OS534E-CF Features OS523E OS524E Parts of the Thermometer Front of the Thermometer Display Details Key General Description General Description Installing the Batteries Ac Power OperationField of View Positions Operating the ThermometerField of View OS534E, OS523E-1 Field of View OS53xE-CF Field of View OS523E-3 Measurement Techniques 11 Recorder Hookup 12. General Operational Block Diagram Real Time Mode Active OperationReal Time Modes 13. Visual Function Flow Chart Using the Trigger Function Adjusting EmissivityUsing the Lock Function Must be hard, flat, and reflective to ultrasonic pulse Using the Distance FunctionDS = 17. Field of View of Distance Meter HH-DM Laser Sighting Status Calculating Temperature ValuesThermocouple Input OS532E, OS533E, OS534E Changing the Temperature from F to C or vice VersaTurning on the Display Backlighting Using the Alarm Functions To set the low alarm value OS533E, OS534E, OS523E, OS524E Use the Ambient Target Temperature Compensation MB RAM Sending temperature data to PC in Real Time Communicating through Hyper terminal Download Stored Temperature data to PCMenu Description Using the Handheld Infrared Thermometer Ascii PC Interface CommandsString Description Storing Temperature Data on Command OS534E, OS523E, OS524E Logging Temperature Data in Real Time OS523E, OS524E,OS534E Erasing the Temperature Data from Memory Mode Recall Mode Passive OperationRecall Modes Reviewing the Last Parameters Laser Sighting Right Side View DescriptionOperating the Laser Sighting Two Laser ConfigurationsLines of Sight of the Laser Sighting and Thermometer Sighting Scope Installing and Operating the Sighting ScopeInstalling the Sighting Scope Menu Selection Battery InstallationDigital Video Camera Camera Parts Turning Camera ON/OFFDigital Video Camera Maintenance Replacing the Batteries Safety WarningServicing the Laser Sighting Cleaning the LensCalibrating the Thermometer Problem Solution Troubleshooting GuideTroubleshooting Guide Problem Troubleshooting Guide Specifications Specifications are for all models except where notedGND With Built-in Distance Module Laser Sighting Digital Video Camera Specifications Glossary of Key Strokes Glossary of Key Strokes Appendix How Infrared Thermometry Works a Thermal RadiationBlackbody Calculating Temperature Optics Field of View Appendix Emissivity Values MetalsNonmetals Appendix Determining an Unknown Emissivity Figure C-1. Determining Emissivity Figure C-2. Determining Emissivity with a Drilled Hole Appendix Determining an Unknown Emissivity Index Field of View Diagrams Recall WARRANTY/DISCLAIMER PH/CONDUCTIVITY Shop online at omega.com