Kohler K-12106-H, K-12105-H manual Electrical Connections, Water Test Whirlpool and Electronics

Page 12

8.ELECTRICAL CONNECTIONS

A.IDENTIFY ELECTRICAL REQUIREMENTS

The model number is printed on a label at the pump end of the whirlpool.

The label identifies electrical rating.

B. WIRING INFORMATION ± 120 V, 60 HZ ±

2-SPEED PUMP (UL LISTED) MODELS

WARNING: Risk of electrical shock. To reduce

the risk of electric shock, connect only to a properly grounded, grounding-type receptacle, protected by a Ground-Fault Circuit-Interrupter (GFCI). Do not remove the plug's grounding pin. Do not use a grounding adapter.

Your Kohler whirlpool bath is equipped with a cord and plug. All wiring of the pump and control has been completed at the factory. A licensed electrician must install a GFCI-protected, 120 V, 20 A, grounded outlet. Your whirlpool may then be plugged into this outlet. No other load should be on this circuit. Locate the outlet behind the whirlpool, and within 24º of the pump.

*For bonding in accordance with national and local codes.

Switch

20 A

Receptacle

Plug-in

Cord

Wire

Bonding

(Earthing) Lug*

Pump

Control Box

9. WATER TEST WHIRLPOOL AND ELECTRONICS

Check all electrical connections.

Make sure all pipe connections to the pump are securely tightened.

Fill the whirlpool to a level at least 2º above the top of the highest jet.

Operate the whirlpool for 5 minutes, and check all whirlpool harness (piping) connections for leaks.

For additional information on whirlpool operation, see

Start-Up Whirlpool instructions on Page 14.

115982-2-BA(-)

12

Kohler Co., Kohler, WI

Image 12
Contents Freewill Barrier Free Bath Whirlpools 12105-H* K-12106-H Important Safety Instructions Table of Contents IntroductionRequired Electrical Service Installation NotesOrdering Information Product InformationProduct Notices Product RequirementsInstallation Requirements NEW or Replacement Installation RequirementsElectrical Requirements Tools RequiredUser Access Considerations Site RequirementsOLD Bath Removal Subfloor PreparationPlumbing Access Considerations Other Installation ConsiderationsBefore Installing Unit Partially Install Bath DrainStud Pocket Preparation Plumbing PreparationInstall the Whirlpool Whirlpool SET-INInstall Plumbing Pump Banding Strap CUTElectrical Connections Water Test Whirlpool and ElectronicsIdentify Electrical Requirements Complete Installation Install Whirlpool Trim KITInstall Faucet and Drain Trim Install Extra Grab BarsCLEAN-UP After Installation Install Shower RODShower Door Installation Confirm Proper OperationTroubleshooting Procedures Flexjet InstallationOperating Sequence Symptoms Troubleshoot Whirlpool SystemProbable Causes Recommended Action