English
|
| Espree™ Bathtub Series | |
Troubleshooting Procedures |
|
| |
PROBLEM | PROBABLE CAUSES | REMEDY | |
|
|
| |
Pump/motor does not start | No power to pump/motor | Reset GFCI | |
Pump/motor not plugged in | Insert plug securely into outlet | ||
| |||
|
| Unsure that the tubing used to activate the pump/motor | |
|
| is tightly secured to the bottom of the ON/OFF control | |
|
| pad and to the AIR switch on back of the motor. | |
|
|
| |
| Pump/motor faulty | Contact Jacuzzi Luxury Bath @ | |
|
|
| |
Pump/motor operates but not the multidirectional or | Jets are closed | Open jets by rotating | |
adjustable jets |
|
| |
Suction cover/strainer may be clogged | With the motor turned OFF, remove the suction cover/ | ||
| |||
|
| strainer and remove any debris. Replace the suction | |
|
| cover before operating | |
|
|
| |
Pump/motor operates but air is not injected into the | Air valves are closed | Open air control valves | |
water |
|
| |
|
|
| |
Water leakage from pump unions | Overtightened, | Loosen unions , check and reseat | |
| seated, undertightened | been pinched out of shape, replace (refer to number | |
|
| below). When tightening union nuts, handtighten only. | |
|
|
| |
Pump/motor shuts off by itself before time elapses | Motor thermal protection has deactivated pump/motor | Let motor cool; thermal protection will reset. Check for | |
| due to overheating (supply voltage low) | proper ventilation (check supply voltage) | |
|
|
| |
| GFCI tripped | Reset GFCI. If it continues to trip, do not use this unit. | |
|
| Disconnect the unit and have the problem corrected by | |
|
| a licensed electrician before using. | |
|
|
| |
| Inadequate supply wiring | Consult a licensed electrician to correct the wiring unit. | |
|
|
|
If the unit is within the warranty period, contact Jacuzzi Whirlpool Bath Service Support at
Page 20 | www.jacuzzi.com | Installation and Operation |