OPERATING INSTRUCTIONS

TURN-ON INSTRUCTIONS

Reference Figures 3 and 4 for proper input and output signal wiring.

1.Apply power to the instrument.

2.Verify the instrument readout blanks momentarily, then displays the value of the input signal. If the display blinks continuously it is because the Model 951 is not receiving a signal. Check wiring.

3.If your Model 951 was calibrated at the factory, youʼre ready to go. If it was not factory calibrated see page 13..

PROGRAM INSTRUCTIONS (Refer to program menu diagram on page 17)

Five front panel switches (S1, S2, S3, S4 and S5) allow the user to program Flow Controller Setpoint Output Voltage (StPt), Digital Alarm Setpoints (SPH1, SPL1, SPH2 and SPL2), Alarm Hysteresis (HH and HL), Calibration Value (CAL) and Decimal Points (dP) and monitor minimum, maximum or real time values.

����������������

 

 

 

CAL

 

 

 

TARE

 

 

 

H1

 

 

 

H2

MENU

ZERO

CAL

L1

L2

 

 

 

S1 S2 S3 S4 S5

1. Depress MODE (S1) switch once.

The text ���� will be displayed momentarily followed by the current value for the Flow Controller Setpoint. Use switches S2 and S3 to set the StPt value. Proceed to Step 2 to set Alarm Set Point H1 (SPH1) or depress S4 to exit the MODE sequence. If S4 is depressed the latest StPt value is used to generate a new Flow Controller Setpoint output voltage.

Page 10

Image 11
Contents Sierra Model Digital Flo-Box Description SpecificationsWiring Installation and WiringInstallation Annunciator leds 15 vdc Increment Switch S2 Switch and Function DefinitionsSwitch Definitions Menu Switch S1Cal Switch S5 Step and Min-Max Switch S3Zero and Exit Switch S4 Flow Set Point StPt Alarm Set Point High 1 SPH1Alarm Set Point Low 1 SPL1 Function DefinitionsAlarm Hysteresis Low HL Alarm Set Point High 2 SPH2Alarm Set Point Low 2 SPL2 Alarm Hysteresis High HHDecimal Point dP S1 S2 S3 S4 S5 Operating InstructionsTURN-ON Instructions Page Page Calibration Instructions Page Special Order Only RS232 Serial CommunicationsSerial Lockout FS CAL Model SR5 Program Menu Diagram