Sierra 951 instruction manual Description, Specifications

Page 2

DESCRIPTION

The Model 951 Digital Flow Box is a microprocessor-based digital indicator and power supply, capable of interfacing directly to a mass flow meter or a mass flow controller. The integrated +/-15 vdc @250ma power supply provides a well regulated, short circuit and thermal overload protected output. It is packaged in a small 1/8 DIN, 5.5" deep extruded aluminum housing which provides excellent EMI/RFI shielding and good heat dissipation characteristics.

The Model 951 is a state-of-the-art product and uses the latest surface mount components. The internal microprocessor provides the following capabilites.

Pushbutton Zero and Full Scale Calibration

Front Panel Setup of Flow Controller Setpoint Voltage (0-5 vdc) Front Panel Setup of (2) High and (2) Low Digital Alarms with open collector outputs.

SPECIFICATIONS

 

Signal Input:

0-5 vdc

Input Resistance:

> 1 Megohm

Input Bias Current:

< 1 na

Display Type:

0.4" high efficiency red LED's

Max display range:

+/- 99,999 counts

A/D Resolution:

+/- 19,999 counts

Linearity:

+/- 0.01% FS +/- 1 count

FS Accuracy:

+/-0.01% FS +/- 1 count

FS Step Response:

500ms (typ)

Overrange Display:

Flashing digits for input > 5.5 vdc

No Sensor Indication:

Flashing digits

Flowmeter Setpoint Output: 0-5 vdc

Flowmeter Power Supply:

+/- 15 vdc +/- 5% @ 400 mA (max)

 

+/- 15 vdc +/- 5% @ 250 mA (min)

Operating range:

-10 to +50 degC

Input Power:

100, 110 and 240 VAC

 

(solder pad jumper selectable)

Pkg dimensions:

3.78W x 1.89H x 5.13D

Page 1

Image 2
Contents Sierra Model Digital Flo-Box Specifications DescriptionWiring Installation and WiringInstallation Annunciator leds 15 vdc Menu Switch S1 Switch and Function DefinitionsSwitch Definitions Increment Switch S2Cal Switch S5 Step and Min-Max Switch S3Zero and Exit Switch S4 Function Definitions Alarm Set Point High 1 SPH1Alarm Set Point Low 1 SPL1 Flow Set Point StPtAlarm Hysteresis High HH Alarm Set Point High 2 SPH2Alarm Set Point Low 2 SPL2 Alarm Hysteresis Low HLDecimal Point dP S1 S2 S3 S4 S5 Operating InstructionsTURN-ON Instructions Page Page Calibration Instructions Page RS232 Serial Communications Special Order OnlySerial Lockout Model SR5 Program Menu Diagram FS CAL