Braun NL955 manual Lift Actions and Functions, Deploy A-C

Page 10

Lift Actions and Functions

DEPLOY (A-C)

A.UNFOLD (Out) - Platform Unfold: Unfold is the action of the platform rotating out and down from the fully-stowed (vertical) position to floor level (horizontal) position when the UNFOLD switch is pressed.

B.DOWN - Platform Lower:

Down is the action of the platform lowering from floor level position to fully-lowered (ground level) position when the DOWN switch is pressed.

C.DOWN - Outer Barrier Unfold (Deploy) - When the platform reaches the fully-low-

Lift Terminology

ered (ground) position and the DOWN switch is continued to be pressed, the outer barrier rotates downward from vertical position to ramp position.

STOW (D-F)

D.UP - Outer Barrier Fold (Raise): When the lift is fully lowered and the outer barrier is in the ramp position, pressing the UP switch first rotates the outer barrier upward from ramp position to vertical position.

E.UP - Platform Raise: Up is the action of the platform raising from ground level to floor level (fully-raised) position when the UP switch is pressed.

F.FOLD (In) - Platform Fold: Fold is the action of the platform rotating up and in from the floor level (horizontal) position to fully- stowed (vertical) position when the FOLD switch is pressed.

Stowed Position: The lift is stowed when the lift platform has been fully raised and folded fully (vertical position).

Floor Level: Floor level is the position (height) the platform as- sembly reaches in order for the wheelchair passenger to enter and exit the vehicle (fully raised). The platform automatically stops at floor level when unfolding from the stowed position and when raising from ground level.

Page 8

Image 10
Contents Operators Manual for Congratulations Contents Warranty and Registration Instructions Series No Pump CodeWarranty and Registration Instructions Lift Terminology IllustrationIntroduction Lift Components Vehicle and Lift Interlocks Lift Actions and Functions Deploy A-CLift Operation Safety Safety Symbols Safety FIRST! Know ThatLift Operation Safety Precautions Lift Operation Safety Stop powered wheelchairs with the wheelchair controls Lift Operation Safety Operation Notes and Details Control Switches Down Auxiliary Control Switches Braun Corporation After- market Control Systems PolicyLift Features Lift-TiteLatches NL955Disengaged Fully-Deployed Fully-Unfolded Belt-operated Side Entry Outer Barrier Fully-Unfolded Ramp position Operation Notes and Details Operation Notes and Details Lift Passengers Operation Procedure Review Wheelchair-Equipped Occupant Seat BeltsOperation Notes and Details Operation Notes and Details Lift Operating Instructions To Open Doors To Unload Passenger Lift Operating Instructions To Load Passenger Facing outward and lock wheel- chair brakesTo Fold Platform To Close Doors Nhtsa Operations Checklist Follow all Lift Operation Safety Precautions Manual Operating InstructionsTo Unfold Platform Out Down To LowerUp To Raise To Fold PlatformDecals and Antiskid Decals30787 Antiskid Available AntiskidMaintenance and Lubrication DE Door-Ease Purpose Penetrating Oil Maintenance and Lubrication Schedule 750 Cycles1500 Cycles Maintenance and Lubrication Schedule 1500 4500 CyclesMaintenance and Lubrication Schedule Cycle 4500Consecutive IntervalsProviding Access to the World ManualOperators