Operation Notes and Details
Interlock: The outer barrier senses weight to prohibit lift operation if occupied.
Side Entry: When the platform lowers fully to ground level, the
WARNING
Discontinue lift use immediately if any lift component does not operate properly. Failure to do so may result in serious bodily injury and/or
property damage.
barrier (when DOWN switch is activated). See photos A and B. The belt and chain driven side entry is powered by the barrier cylinder to automatically fold (ro- tate) to the vertical position when the UP switch is activated.
Outer Barrier Latch: A spring- loaded latch engages the outer barrier when the barrier rotates upward from ramp position to the vertical position (UP switch is activated to raise the platform above ground level).
Note: The platform must raise approximately three inches be- fore the latch engages fully (see photo C on page 22).
The latch disengages the barrier when the platform lowers fully
(reaches ground level) and the latch foot contacts the ground (latch raises above the barrier).
The lift operator or attendant must be certain the entire platform reaches and rests safely on the ground.
Page 23