Graco 333282B important safety instructions Fire and Explosion Hazard

Page 9

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and

plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.

• Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

• Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they are antistatic or conductive.

Stop operation immediately if static sparking occurs or you feel a shock, Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

ELECTRIC SHOCK HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.

Turn off and disconnect power at main switch before disconnecting any cables and before servicing or installing equipment.

Connect only to grounded power source.

All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

333282B

9

Image 9
Contents Color Change and Remote Mix Manifold Kits Important Safety InstructionsContents Related Manuals Manual No DescriptionManual No Non-Intrinsically Safe Modules ModelsControl Module Pressure Valves Kit Identification Label Intrinsically Safe Modules 0359 Number of Catalyst + Solvent ValvesModels continue on next 333282B Models Fire and Explosion Hazard Intrinsic Safety Personal Protective Equipment Isocyanate Conditions Important Isocyanate ISO InformationMoisture Sensitivity of Isocyanates Changing MaterialsSetup Non-IS Control Modules Setup the ModulesColor Change Control Modules, Colors, and Catalysts ModuleNon-IS Control Module Switch Settings Inlet ManifoldOutlet Manifold Inlet Manifold Outlet Manifold Solenoid Valve Is Control Module Switch Settings Setup is Control ModulesIs Control Module Valve Solenoid Is Control Module Solenoid ValveMounting the Control Modules InstallationAir Supply GroundingConnect the Color Change Control Modules Non-Hazardous LocationInstall the Valve Manifolds Install the Valve ManifoldsInstallation Connect Remote Color Change Control Module Hazardous LocationInstall the Remote Valve Manifolds Connect the Valve Air Lines Install the Remote Mix ManifoldNon-Hazardous Area Hazardous AreaInstallation Valve Manifold Stack Schematic Connect the Fluid LinesConnect Non-Circulating Fluid Lines KEY Valve Manifold Connections Circulating System Connect Circulating Fluid LinesKEY Install an Expansion Kit Install an Expansion Kit Low Pressure Valve Manifold Shown Troubleshooting Cause SolutionColor Change Solenoid Valves Replace the Color Change Board Fuse, Color Change Board Troubleshooting Power Module Electrical SchematicsEfcm Cable J8 J9 J15 J16 J14 J10 J15 J16 Electrical Schematic, Sheet 3, Hazardous Location Optional Cables and Modules Replace a Color Valve RepairReplace a Solenoid Replace the Color Change Board FuseFuse Description Control Module Repair Non-IS Module Shown Replace the Color Change BoardNon-IS Color Change Kits PartsPart Description Qty Low Pressure Non-IS KitsKit No Kit Description High Pressure Non-IS KitsHigh Pressure Non-Circulating Color Change Kits High Pressure Circulating Color Change KitsParts Description Qty Is Color Change KitsAll available kits Parts Low Pressure is KitsHigh Pressure is Kits Low Pressure Valve Manifold Kits Valve Manifold KitsNon-Circulating Valve Manifold Kits Kit No Series Circulating Valve Manifold Kits Kit NoValve Manifold Kit Parts Kit No Parts Low Pressure Circulating Valve Manifold Kit Part Quantities Circulating Valve Manifold Kits Kit No Series High Pressure Valve Manifold KitsValve Manifold Kit Parts 24T581 Parts High Pressure Circulating Valve Manifold Kit Part Quantities Parts Non-IS Color Change Control Modules Color Change Control Module KitsKit No Position Solenoid Plug Tie Strap Ferrule Connector Connector 310 321 322 Fitting 305 324Non-IS Control Module Part Quantities Is Color Change Control Modules Is Control Module Part Quantities 16M00Parts Non-IS Expansion Kits Expansion KitsLow Pressure Expansion Kits High Pressure Expansion Kits High Pressure Acid-Compatible Expansion KitsLow Pressure Expansion Kits Is Expansion KitsDimensions Manifold Mounting Bracket, Non-IS 11.44 312 Mm diameter Dimensions Dimensions Color Change Kits Metric Technical DataGraco Information Graco Standard Warranty