INSTALLING YOUR VOICE TERMINAL

IMPORTANT: For a fuller description of installing the 8400-Series voice terminals and procedures on administering these sets and programming such options as enabling/disabling the speakerphone or one-way speaker, enabling/disabling the Mute function, selecting ringing preference, or selecting handset and speaker volume control, see the 8400-Series Voice Terminals Instructions for Installation, Switch Administration, and Programming the Options, 555-015-725. (This document can be ordered from the Lucent Technologies BCS Publications Center at 1 800 457-1235.)

Distance Limitations

In 4-wire operation, the voice terminal must be within 5,000 feet of the PBX using 22-gauge or 24-gauge wire, and within 4,000 feet of the PBX using

26-gauge wire.

In 2-wire operation, the voice terminal must be within 5,500 feet of the PBX using 22-gauge wire, within 3,500 feet of the PBX using 24-gauge wire, and within 2,200 feet of the PBX using 26-gauge wire.

Auxiliary Power

In both a 4-wire or 2-wire configuration, most 8400-Series voice terminals are phantom powered from the PBX. However, you will need auxiliary power in the following instances:

If you are using an 8411 or 8434DX voice terminal (These sets require auxiliary power.)

If you have an 801A Expansion Module (used ONLY with the 8434DX voice terminal connected to a DEFINITY® Communications System G3V3.3 or later switch)

If there is an attached adjunct equipment, such as an S201A Speakerphone

The following power supplies can be used with the 8400-Series voice terminals:

Stand-alone 1151A1 Power Supply (PEC: 2404-010;

Comcode: 107785693) and 1151A2 Power Supply with Battery Holdover

(PEC: 2404-012; Comcode: 107785339)

Stand-alone MSP-1 (PEC: 2404-010; Comcode: 406743419)

1145A Bulk Power Supply (PEC: 2404-011;

Comcode: 106448939)

Battery for the 1145A (2.5 amp per hour battery) (Comcode: 106448921)

1

Image 8 Contents
8400-Series Voice Terminals Installation and User’s Manual Do not Discard the Blank Designation Card Important User Safety Instructions Service Important Safety Warnings for Installation Additional Installation Warning Using the RS-232-D Jack and Analog Other 8400-SERIES Voice Terminals DocumentationDistance Limitations Installing Your Voice TerminalAuxiliary Power General Notes for Installation Desktop InstallationPage Routing channel For line cord Analog Adjunct jack RS-232-D jack Line jack Adjunct jack Expansion Handset Module jack Adjusting the 8405 and 8410 Voice Terminal Desktop Stand Adjusting the 8405 and 8410 Desktop Stand Wall Installation To wall-mount the 8403, 8405, and 8410 voice terminalsRemoving the Desktop Stand on the 8403, 8405, Placing the Voice Terminal onto the Wall Jack Mounting Studs Attaching Adjunct Equipment D6AP Using the RS-232-D Jack and Analog Adjunct Jack on Important Notes forTo connect your 8411 to the PassageWay PC To connect an Analog Adjunct toPassageWay and Analog Adjunct Status Indications on Location of Buttons #9 and #10 onPassageWay Status Indications PassageWay StatusGreen Light Red LightFor the 8405, 8410, and the 8411 Voice Terminals Labeling the Designation CardFor the 8403 Voice Terminal To label the designation card How to Label the Blank Designation CardFor the 8434DX Voice Terminal Programming Options on the 8411 Voice Terminal While on-hook, press Current setting Enable T/R Status Lamps or Other 8400-SERIES Voice Terminals Documentation Voice Terminal Quick Reference Guide Definity Communications System Generic 2 and System