Grandstream Networks DP710 manual 10/100Mbps RJ-45 port toconnect to the network

Page 10

 

 

 

 

 

Table 2: DEFINITIONS OF THE DP715 CONNECTORS

 

 

 

 

 

 

 

 

 

DC 6V

 

 

Power adapter connection.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NETWORK PORT

 

 

10/100Mbps RJ-45 port toconnect to the network.

 

 

 

(RJ-45)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RESET

 

 

Factory Reset button: Press for 7 seconds to reset factory default settings.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 3: BASIC DEFINITIONS OF THE DP715 LEDS PATTERN

 

 

 

 

 

 

 

 

 

 

 

LEDs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER LED

 

 

 

Indicates Power. Remains green when power is connected, and orange when handset is

 

 

 

 

 

 

 

 

connected for charging.

 

 

 

 

 

 

 

 

 

 

 

NETWORK

 

 

 

Indicates Access to the Network. Remains ON while there is Access to the Network

 

 

 

 

 

 

 

 

 

 

 

REGISTERED

 

 

 

Indicates if the SIP accounts are registered

 

 

 

 

 

 

 

 

 

 

 

CALL

 

 

 

Indicates status of active calls.

 

 

Table 4: ADVANCED DEFINITIONS OF THE DP715 LEDS PATTERN

 

 

Pattern

 

 

 

Condition

 

 

 

LED

 

 

 

LED Behavior

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-01

 

 

 

Device has normal power

 

 

 

POWER

 

 

 

GREEN ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-02

 

 

 

Handset is placed on base with battery to charge

 

 

 

POWER

 

 

 

ORANGE ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-03

 

 

 

Power Error: Power is removed from the device

 

 

 

POWER

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-04

 

 

 

Power supply with improper voltage is plugged in

 

 

 

POWER

 

 

 

Blink ( 0.5s on/ 0.5s off )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-05

 

 

 

Device has normal LAN connection and has obtained an

 

 

 

NETWORK

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP address

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-06

 

 

 

Link Down

 

 

 

NETWORK

 

 

 

Blink (1s on/ 1s off).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note : This is the default state while the device is booting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-07

 

 

 

Link Up but DHCP error

 

 

 

NETWORK

 

 

 

Blink ( 0.25s on/ 0.25s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-08

 

 

 

Link Up but PPPoE error

 

 

 

NETWORK

 

 

 

Blink ( 0.5s on/ 0.5s off )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-09

 

 

 

All configured SIP accounts are registered

 

 

 

REGISTERED

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-10

 

 

 

SIP accounts are in the process of registering

 

 

 

REGISTERED

 

 

 

Blink ( 1s on/ 1s off )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-11

 

 

 

Device is booting, application has not started.

 

 

 

REGISTERED

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-12

 

 

 

No account is configured on DP715

 

 

 

REGISTERED

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-13

 

 

 

Registration Error - ANY SIP account experiences

 

 

 

REGISTERED

 

 

 

Blink ( 0.5s on/ 0.5s off -

 

 

 

 

 

 

 

 

registration failure.

 

 

 

 

 

 

05s on/ 2s off )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-14

 

 

 

Call is active. Any DECT handset is in an active call with

 

 

 

CALL

 

 

 

Blink ( 0.5s on/ 0.5s off )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

an external line.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-15

 

 

 

No active call.

 

 

 

CALL

 

 

 

OFF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-16

 

 

 

DECT Error

 

 

 

 

 

 

 

5 sequence of Blink

 

 

 

 

 

 

 

 

 

 

 

 

CALL

 

 

 

(0.25s on/0.25s off) + 3s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-17

 

 

 

VMWI

 

 

 

 

 

 

 

Blink (0.25s on/ 0.25s off -

 

 

 

 

 

 

 

 

 

 

 

 

CALL

 

 

 

0.25s on/ 0.25s off - 0.25s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

on/ 0.75s off)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-18

 

 

 

Boot up

 

 

 

ALL

 

 

 

GREEN ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED-19

 

 

 

Factory reset

 

 

 

ALL

 

 

 

GREEN ( 0.25s on/0.25s

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

off – 0.25s on/0.75s off )

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Firmware version 1.0.0.23

DP715/DP710 User Manual

Page 10 of 52

Image 10
Contents Grandstream Networks, Inc Index Call Features DP715 Base Station Configuration Guide DP715/DP710 U SER M Anual GNU GPL Information Change LOG Warranty Safety CompliancesWelcome Firmware version Equipment Packaging Connecting the DP715 Base StationConnect Your DP715/710 Equipment Packaging10/100Mbps RJ-45 port toconnect to the network Advanced Definitions of the DP715 Leds PatternConnecting THEDP710 Charger Unit Setting UP the DP715/710 HandsetDP715/DP710TECHNICAL Specifications Software Features OverviewProduct Overview Hardware Specifications DP715/710 Hardware SpecificationsHandset Keys Description Using the DP715/710 HandsetGetting Familiar with the Handset Handset KeypadPage Upper Case Battery DisplayHandset Display Structure LCD AbcHandset Menu Structure Range IconHandset Menu Overview Call History Handset Menu Description Turning the Handset ON/OFFConsult the Call History Delete all Calls PhonebookDeleting a Call Saving a New Entry in the PhonebookDisplay the Details of Phonebook Entries Delete an Entry or All EntriesTo Show Details and press Selecting the Menu Language ACTIVATE/DEACTIVATE HANDS-FREE ModeSetting the Loudspeaker Volume Muting the MicrophoneSetting the Ringer Volume on the Handset Setting the Ringer Melody on the HandsetEnable the Keypad Lock Setting the KEY LockAdjust the Display Contrast Disable the Keypad LockEdit Handset Name Setting AN AlarmSwitching the Alarm Off Time 24hr 0700Appointments Stop WatchUnderstanding DP715/710 Voice Prompt Basic OperationsDP715/710 IVR Menu Definitions Registering a Handset to the DP715 Base Station Device not registeredAnswering Calls Using the PhonebookCompleting Calls DialDirect IP Calls Using IVRInternal Calls Elements necessary to complete a Direct IP CallCall Waiting Call HoldCall Transfer Attended Transfer WAY ConferencingInstructions for 3-way conference Call Features DP715/710 Call Feature DefinitionsConfiguring the Base Station Through Voice Prompts DP715 Base Station Configuration GuideConfiguring the Base Station VIA WEB Browser Dtmf Methods Important SettingsNAT Settings Preferred Vocoder CodecBasic Settings MTZ+6MDT+5NAT StatusIpui Tpui Advanced Settings Advanced User ConfigurationSIP DND HTTP/HTTPS ACS URL Profile Settings Disable Bellcore Style Advance Configuration DNS ModeUnregister on Reboot Tel URIInvite Dial Plan Disable Call-WaitingCaller ID Disable Reminder Ring Subscribe for MWIVAD Handsets Settings Rebooting the DP715 Base Station from Remote Saving the Configuration ChangesConfiguring the DP715 Base Station Through a Central Server Software Upgrade Firmware Upgrade Through TFTP/HTTP/HTTPSFirmware and Configuration File Prefix and Postfix Instructions for Local Firmware Upgrade Using Tftp ServerConfiguration File Download Instructions for Upload from Local DirectoryManaging Firmware and Configuration File Download Restore Factory Default Setting Base StationHandset
Related manuals
Manual 52 pages 37.18 Kb