Sennheiser SDC 8000 system manual System cables

Page 24

The components of the SDC 8000 system in detail

The system cables

The system cables required for your planned conference and interpretation system must be ordered separately. The system cables are available with lengths of 2 m, 3 m, 5 m, 10 m, 20 m and 50 m.

Via the system cables, you can:

yinterconnect the conference and interpreter consoles,

yinterconnect up to 10 central units for setting up a large conference and interpretation system,

yconnect an SDC 8000 AO analog output unit to the central unit,

yconnect cable strings to the central unit.

The system cables must meet the following specifications:

Shielded RJ 45 modular plug, cat 5(e)

Black cable booth with clip protector

Round STP cable, cat 5(e), 24AWG

Grey cable booth with clip protector

24

Image 24
Contents SDC Thank you for choosing Sennheiser Contents Via a PA system Configuring the interpretation system 100 Appendix a Safety information SDC 8000 the digital conference and interpretation system Overview of the components SDC 8000 system Conference consoles$!# Technology used All consoles feature Components of the SDC 8000 system in detailConsoles Interpreter console features SDC 8000 D conference unit SDC 8000 C chairman unit SDC 8000 DC conference unit SDC 8000 CC chairman unit SDC 8000 DV conference unit Vote LEDSDC 8000 CV chairman unit SDC 8000 ID interpreter console Autofloor LEDSDC 8000 CU central unit SDC 8000 AO analog output unit optional System cables Direct Access mode Operating the components SDC 8000 systemOperating the delegate units Taking the floor / Making a request to speakOperating the components of the SDC 8000 system On your console go off With request mode With Req. No clear modeTurning off the microphone / Cancelling a request to speak Selecting an interpretation channel VotingUsing the chip card slot of a conference console Operating the VIP unitsOperating the chairman unit Turning all active conference consoles off priorityStarting a voting session Assigning a participant the speaking rightRequest Configuring the B-channel of an interpreter console Operating the interpreter consolesUsing the interpreter console Switching between the A-channel and the B-channel Adjusting the volume of the consoles’ built-in loudspeakersOperating the central unit Muting the microphone of the interpreter consoleF1, F2 and F3 menu keys Menu operating controlsOperating control Menu level Working with the central unit’s operating menu Interconnecting the conference/interpreter consoles Connecting cable strings to a central unitInterconnecting up to 10 central units Structuring the SDC 8000 systemExpansion stage 1 one central unit with up to 15 consoles Expansion stage 2 one central unit with up to 90 consolesDetermining maximum cable lengths Structuring an interpretation system Calculating the voltage drop on the system cablesSelectable modes between or within interpreter booths Mode between booths MixedMode between booths Override Mode between booths Toggle OverrideMode in booths Mixed Mode in booths OverrideAuto-floor function ExampleAUTO-FLOOR Using external equipment Connecting external audio sourcesStructuring the SDC 8000 system Setting up the SDC 8000 system Preparing the SDC 8000 system components for set upInterconnecting the SDC 8000 system components Interconnecting the consolesConnecting a cable string to the central unit Interconnecting several central unitsConnecting additional equipment Turning the central units on and offCarrying out remote conferences Connecting PA systems, recording units, etc Pin assignment of the 9-pole sub-D socket AUX OUTDaisy-chaining SDC 8000 AO analog output units Connecting a PC to the central unit Configuring the SDC 8000 system Introduction to the central unit’s operating menuStart display Six main menusEnter Exit Submenus of the Conference menu part 1 Submenus of the Conference menu part 2 Submenus of the Conference menu part 3 Submenus of the Conference menu part 4 Submenus of the Conference menu part 5 Submenus of the Conference menu part 6 Submenus of the Interpretation menu part 1 Submenus of the Interpretation menu part 2 Submenus of the Interpretation menu part 3 Submenus of the Interpretation menu part 4 Submenus of the Interpretation menu part 5 Submenus of the Aux-In/Out menu part 1 EnterSubmenus of the Aux-In/Out menu part 2 Submenus of the Aux-In/Out menu part 3 Submenus of the Aux-In/Out menu part 4 Submenus of the Aux-In/Out menu part 5 Submenus of the Aux-In/Out menu part 6 Submenus of the System menu part 1 Submenus of the System menu part 2 Submenus of the Language and the License menu part 1 Settingthe volume of theconsoles’ built-inloudspeakers Configuring the conference systemTurning on the central unit for the first time Automatically initializing all conference consolesManually initializing all conference consoles Reserving a microphone number Selecting a conference mode Setting the speaker limit Adjusting the audio settings for the consoles’ microphones Resetting the conference systemTesting the consoles’ built-in loudspeakers Testing the consoles’ microphonesConfiguring the interpretation system Configuring the display of the voting optionsWorking with the interpreter configuration Creating a new interpreter configuration Modifying the currently active interpreter configuration Loading a previously saved interpreter configurationSetting the max. number of interpreter booths/languages Setting the max. number of interpreter consoles per boothOptions Configuring the operating mode between booths Configuring the operating mode within a boothConfiguring the language options for the interpreter booths Configuring the main target language A-channel of a boothConfiguring the second target language B-channel of a booth Enabling the auto-relay interpretation function Auto-floor ENG To transmit the selected booth number to Adding interpreter consoles to an existing configuration Resetting the interpretation system Configuring the audio inputs and outputs Adjusting the volume of the audio outputsChoosing the audio inputs and outputs Configuring the audio outputs for remote conferencing Assigning a channel to an audio outputTurning the audio inputs or outputs on and off Adjusting the input level of an audio input Adjusting the input sensitivity of an audio inputConfiguring the outputs of the SDC 8000 analog output unit OUT Configuring connected additional components Making a system diagnosisChecking the communication within a cable string Camera controlConfiguring an ambient sound console Software, language and license Choosing the language of the central unit’s operating menuDisplaying the central unit’s serial number If problems occur Maintenance and careReplacing a fuse Conference/interpreter console does not workAccessories Specifications SDC 8000 DSDC 8000 C SDC 8000 DC SDC 8000 CCSDC 8000 DV SDC 8000 CVSDC 8000 ID 108 SDC 8000 AO analog output unit RJ 45 cableSyntax of the commands Appendix a Camera control protocolCommands Notation of the general syntaxCommands Appendix B Control panel protocol113 Appendix C Repeater for the SDC 8000 system 114115 Approval