Section 4: CS 5 DU Delegate Station

4.1 Introduction

The CS5 DU is the basic microphone station for the CS 5 conference system. It provides a microphone connection with talk button, two built-in loudspeakers, and two headphone jacks.

The loudspeakers reproduce the main mix ("floor signal") while the headphone jacks allow the user to listen to the floor signal or one of three interpreted languages.

4.2 Controls, Inputs, and Outputs

Fig. 4: Controls, inputs, and outputs on the CS5 DU.

1: Mini jack for stereo headphones.

2Microphone input for connecting any of the gooseneck microphones listed in section 2.

3-4 Volume control buttons: The UP button (4) increases and the DOWN button (3) decreases the volume of the built- in speakers or headphones connected to the microphone station.

If no headphones are connected to the microphone station, the volume control buttons set the volume of the built-in loudspeakers.

If a single pair of headphones is connected to either headphone jack, the volume control buttons set the vol- ume for that pair of headphones.

If headphones are connected to both headphone jacks, the volume control buttons set the volume of both head- phone channels.

￿Note: When the microphone is open, the volume of the loudspeakers will be attenuated by a specific amount de- pending on the polar pattern of the microphone used. The headphones volume will not be affected.

CS 5 User Manual

- 19 -

Image 19
Contents Conference System Table of Contents Table of Contents Symbols Used FCC Statement Safety and EnvironmentSafety Instructions EnvironmentGeneral Page Simple Discussion System System ExamplesExample 1 Simple discussion system Example 2 Larger discussion system with computer control Computer-controlled Discussion SystemInfrared Interpretation System Layout Wiring Diagram Example 4 Large conference system layout and wiring diagram Page Front Panel Power Switches power to the Base Unit on I or OFFCS 5 BU Base Unit GeneralRear Panel CS 5 BU Base UnitBlock Diagram Setting Up the Base UnitBase Unit dip switches Configuring the Dip SwitchesSelecting NOM Limitation/Interpretation Channels Setting Levels Powering UpCS 5 BU Base Unit Introduction CS 5 DU Delegate StationControls, Inputs, and Outputs Selecting Operating Modes Setting UpCS 5 DU Delegate Station Making ConnectionsCS 5 DU Delegate Station Control Panel, Inputs, and Outputs CS5 VU Voting/Chairperson StationCS5 VU Voting/Chairperson Station Refer to Mini jack for stereo headphonesFunction Switch positions Press soft button 3 Back to return to the main menu Delegate ModePresident menu and selectable submenus President ModeVoting/Polling Controlling a Ballot or Opinion Poll President Mode… or like this… Voting in Delegate ModePress any button to return to the President main menu Chip Card Identification CS 5 IU control panel, inputs, and outputs CS 5 IU Interpreter StationOutput CS 5 IU Interpreter StationSelecting Target Language Channels Selecting Station AddressesSelect Next press Relay to bring up this screen Selecting the Microphone Type List of Available Language NamesControlling the microphones Using the Interpreter StationMicrophone signal will be automatically routed to output a Select your target languageCS 5 IU Interpreter Station General PlacementInfrared Transmission System CS 5 IRT 1 and CS 5 IRT 2 Infrared RadiatorsConnections Connect each infrared radiator to powerInfrared Transmission System MountingCS 5 IRR 7 Infrared Receiver Replacing Batteries Using the Infrared ReceiverCharging Batteries CS 5 CU 50 Charger/Storage CaseUnlock and remove the lid from the flight case Remove the receiver from the charging slot Battery CareSystem Components CS 5 BU SpecificationsConnector Pinouts SpecificationsSystem CS 5 DU/VU Physical Dimensions Signal/noise ratio WidthDepth Physical Dimensions Width Circuited input Headphone Output PowerCS 5 PS CS 5 IRR CS 5 IRT 1 and CS 5 IRTConformity Quick Charging Mode Charging currentTrickle Charging Mode Charging current CS 5 CU10/09/9100 U