ConnecT/R. You can connect it by plugging it into the TEL DEVICE jack on the ConnecT/R or by plugging it into the wall jack that is connected to the TEL DEVICE jack on the ConnecT/R.

To install two telephone devices on a ConnecT/R, use a T-type adapter (AT&T part # 267A2 or 267A). Plug the adapter into the TEL DEVICE jack (either directly or indirectly through a wall jack, as described above) and plug the telephone devices into the adapter jack.

5.Connect the ConnecT/R to the AC power outlet. Plug the power connector into the POWER jack on the back of the ConnecT/R. To prevent the power cord from pulling out easily, make a small loop of cord near the power connector and slip it behind the strain relief tab next to the POWER jack on the ConnecT/R. Plug the wall transformer into an AC power outlet that is at least 3 feet away from the controller and not controlled by a wall switch. (If it is any closer to the controller, you may hear a hum on your SPIRIT System.)

NOTE: Use only a UL Listed wall plug-in power transformer that has Class 2 outputs and the following characteristics:

Input rating:

99-127 V AC rms 60 Hz

 

150 mA maximum

Output rating:

27-35 V DC at 200 mA

 

14-18 V DC at 200 mA

The power transformer supplied with the ConnecT/R has these characteristics.

AC

Power Outlet

ConnecT/R

Image 16
Contents Spirit Table of Contents Important Safety Instructions Input rating Introduction Spirit ConnecT/RPage ConnecT/R Installation Installation InstructionsSpirit ConnecT/R without Attached Spirit Telephone Telephone Device Business Requirement ModePage Page Mount the ConnecT/R optional Page Station Jack Input rating Test the equipment Using the Telephone Device Answering CallsPaging Interactions with Spirit System Features Features Interactions LimitationsHfai Lifting Troubleshooting Operational Difficulty What to Check RingingOperational Difficulty What to Check Hold MiscellaneousOperational Difficulty What to Check Cordless Telephone Operational Difficulty What to Check Answer/record MachineCredit Card Readers Facsimile MachineGeneral Operational Difficulty What to Check Modem Appendix a Wiring Requirements Page Index FCC Warning Statement