Motorola RDU2080 manual Battery Life Information, Li-Ion Battery Life with Battery Save feature on

Page 24

RADIO OVERVIEW

Battery Life Information

When the Battery Save feature is ON (enabled by default) the battery life will be longer. The following chart summarizes battery life estimations:

Li-Ion Battery Life with Battery Save feature ON

 

Battery Type

 

5 Watts

4 Watts

2 Watts

Standard

 

8.5 hours

8.5 hours

12 hours

 

 

 

 

 

 

High

 

 

17 hours

17 hours

24 hours

 

 

 

 

 

Ultra High

 

18.5 hours

18.5 hours

26 hours

 

 

 

 

 

Note:

Battery life is estimated based on 5% transmit/ 5% receive/ 90% standby

 

standard duty cycle.

 

 

 

English 22

Image 24
Contents RDX Series Two-Way Radios Page Contents Programming Features Getting StartedTroubleshooting Use and Care Frequency and Code Charts Power Supplies Safety Product Safety and RF Exposure ComplianceBatteries Chargers Safety Information Operational Safety Guidelines Package Contents IntroductionUSA Canada On your TTY Text Telephone FCC Licensing Information Interference InformationFCC Licensing Information Radio Overview Parts of the RadioOn/Off/Volume Knob Accessory ConnectorLED Indicator Model LabelLithium-Ion Li-Ion Battery Side ButtonsPush-to-Talk PTT Button Side Button 1 SB1Model Frequency Band AntennaBattery Features About the Li-Ion BatteryBattery Recycling and Disposal BatteryInstalling the Lithium-Ion Li-Ion Battery Removing the Lithium-Ion Li-Ion BatteryRemoving Alkaline Batteries Attaching and Removing Antenna Installing Spring Action Belt Clip ChargerBattery Life Information Li-Ion Battery Life with Battery Save feature onAlkaline Battery Life Alkaline Battery LifeBattery Meter RDX Series Battery MeterCharging the Battery Charging with the Drop-in Tray Single Unit Charger SUCCharging a Standalone Battery Charging a Standard BatteryCharging a High Capacity or Ultra High Capacity Battery Drop-in Tray Charger LED Indicators Standard Charger LED IndicatorRapid Charger LED Indicator Charging Battery Type Solution Estimated Charging TimeEstimated Charging Time MUC LED Indicator Adjusting Volume Getting StartedTurning Radio ON/OFF Reading the DisplaySelecting a Channel Talking and MonitoringReceiving a Call Signal Strength Indicator and Channel Busy Indicators Talk RangeGetting Started Radio LED Indicators Radio Status LED IndicationWith Compatible VOX Accessories HANDS-FREE USE/VOXHands Free without Accessories iVOX Battery SaveReset to Factory Defaults End of Transmission Tone Roger Beep Tone Keypad BeepsKeypad Lock/Unlock Menu OptionsSetting VOX / iVOX sensitivity IVOBattery Type Menu LithiumProgramming Features Entering Programming ModeProgramming RX Reception Frequencies Programming RX Reception Codes CTCSS/DPL Programming ScrambleMA X CH Programming Maximum Number of ChannelsTone Programming Call TonesProgramming Microphone Accessory Gain Level Programming Microphone Gain LevelOther Programming Features ScanYES Programming Scan ListProgramming Buttons Editing Channel Alias NameEnglish Nuisance Channel Delete CPS Computer Programming SoftwareTime-Out Timer Power SelectBandwidth Select Battery Type Setting Call TonesScramble Reverse BurstCloning with a Multi-Unit Charger MUC HeardOperating Instructions What to do if cloning fails Cloning Radios using the CPS Computer Programming Software Repeater CapabilitiesProgramming Repeater Capability Programming Features Programming Features Troubleshooting Symptom Try ThisRange. Check for clear line of sight to improve transmission Troubleshooting VOX feature might be set to OFF USE and Care Frequency and Code Charts RDX VHF FrequenciesFrequency # Frequency # Bandwidth RDX VHF 8CH Radios Default Frequencies RDV2080d Channel Frequency # Code # BandwidthRDX UHF Frequencies Chart RDX UHF FrequenciesFrequency # Frequency Bandwidth MHz Frequency # Frequency and Code RDU2080d UHF Default Frequencies Chart RDX UHF 8 CH Radios Default Frequencies RDU2080dRDU4160d UHF Default Frequencies Chart RDX UHF 16 CH Radios Default Frequencies RDU4160dFrequency and Code Frequency and Code Ctcss and PL/DPL Codes Ctcss CodesPL/DPL Codes Code111 Frequency and Code Programming Customized Frequencies on 4W/5W RDX Models Motorola Limited Warranty for the United States and Canada What Does this Warranty Cover?Products and Accessories Warranty ExclusionsHOW to Obtain Warranty Service or Other INFORMATION? SoftwareWHO is COVERED? Software Copyright NoticePatent Notice Export LAW AssurancesAccessories Audio AccessoriesBattery AntennasCarry Accessories Power Supplies AC PIN AdaptorsSoftware Applications CablesPower Supplies Battery Save Battery TypeButtons Reset Display BacklightDisplay Call TonesChannel AliasingCloning Mode CPS ManagerLock End of TxIVOX, enable DisableDisplay Frequencies Direct InputLEDs Enabled Disabled Low BatterySensitivity LevelDisplay Microphone Gain LevelMonitor Nuisance ChPower Select Power up TextTalkaround Reset to DefaultsReverse Burst Timer Display ScanScan List Scan, AutoVOX, enable VOXProgrammable Buttons Chart Icons Chart Signal Strength RepeaterVox/IVox Page NNTN8303A