AT&T Door Phone Controller operation manual Remote Door Open Switch optional

Page 29

Connecting Door Speaker, Door Button, and Door Ajar Switch to the AT&T Door Phone Controller

Polarity of wires is not important.

Total wire length should not exceed 1500 feet.

Door Ajar switch should be closed when door is closed. If a door ajar switch will not be used, you must leave a jumper installed across the two “Door Ajar Switch” terminals.

Use the diagram in Figure 2-4and follow the steps below:

1.Run shielded twisted pair wires (22–24AWG) from the “Speaker” terminals on the rear panel of the AT&T Door Phone Controller (13 & 14) to the installed Door Speaker (1 & 2). Connect the shield to the “Shield” ter- minal on the controller (12).

2.Run 2 wires (22–24AWG) from the “Door Bell Button” terminals (10 & 11) to the door bell push button on the installed door speaker/push button assembly (3 & 4).

3.Run 2 wires (22-24AWG) from the optional “Door Ajar Switch” terminals (8 & 9) to the installed door ajar switch.

Remote Door Open Switch (optional)

A remote door open switch (normally-open contact) provides additional means for opening an electric door opening device. To connect wires for a remote door open switch use the diagram in Figure 2-5and follow the steps below.

1.Install the remote door open button in desired location using manufacturer’s installation instructions.

2.Run 2 wires (22–24AWG) from the installed (normally- open contact) remote door open switch to the “Remote Door Open” terminals (6 & 7) on the AT&T Door Phone Controller back panel (polarity of wires is not important).

Installation Procedures

2-13

Image 29 Contents
AT&T Compatibility Plus AT&T Door Phone Controller Compatibility ChartApplication Notes for Compatibility Chart Application Notes for Compatibility Chart Contents Troubleshooting and Maintenance Page Figures Page Tables Introduction Using This Manual AT&T Door Phone Controller FeaturesSpeaker Volume Talk Back DIP Switch LED PBX Private Branch Exchange -Business telephone Terms You Should KnowInstallation Procedures Installation Procedures Important Safety Instructions Page General Information Door Phone Controller Back Panel Connections IntroductionPage Door Phone Controller Back Panel Connections Prior To Installation AT&T Door Phone Controller Location Typical AT&T Door Phone Controller Installation Wall Mount Instructions InstallationMounting Instructions Mounting AT&T Door Phone Controller to Wall Remote Door Open Switch optional SHIELDED, Twisted PAIR, 24 AWG Electric Door Strike Plate Device optional Connections for Remote Door Open Switch optionalConnections for Electric Door Strike Plate optional Auxiliary Alert Device optional Connecting PowerConnections for Auxiliary Alert Device optional Installation Procedures Talk Back Volume Control Speaker Volume ControlOperation and Controls Information Door Ajar FunctionLED Configuration of Telephone Equipment Flow Chart Installation Home/Residential Overview DIP Switch SelectionsHome/Residential DIP Switch Settings AT&T Door Phone Controller Back Panel Option Selection AT&T Door Phone Controller Option Selection Information Answering a Call from the Door Speaker Operation Basic Door Answer FunctionVisitor Presses Door Speaker Button Calling the Door Speaker from Inside the Building Telephone Line In Use With Door When Incoming Call Arrives Installation Dedicated Trunk Port Overview DIP Switch Setting for PBX with Dedicated Trunk Port Telephone System 2b. Ground Start Installations Option Selection Page Options Mode Option Press Listen Default Verify For Calling the Door Speaker Installation for PBX Equipment With Available Station Port Overview G E ND Telephone System Option Selection Page Options Mode Option Listen Press Default Verify For Operation Auxiliary Alert Mode Basic Door Answer FunctionRingdown Mode Basic Door Answer Function Opening door will terminate station mode access Installation No Dedicated Trunk/Station Port DIP Switch Selections DIP Switch Setting for PBX With Shared Trunk Port AT&T Door Phone Controller Back Panel Option Selection Port Saver Mode Port Saver or Trunk Saver Mode InstallationTrunk Saver Mode Delay Operation Basic Door Answer Function Calling the Door Speaker From Inside the Building Placing a Call Through the C.O. From Inside Building Telephone Line In Use With Door When a Call ArrivesTroubleshooting and Maintenance Troubleshooting Procedures Troubleshooting ProceduresWhen door ajar switch is not Operating as Expected MaintenanceSetting the DIP Switch Positions Appendix A-DIP Switch SettingsNot used Ring/Chime Cadence Ring/Chime Duration Appendix B-Option Selection Mode DefinitionsPage Electrical Appendix C-SpecificationsRing Generator Line Jack MechanicalInstallation Information Using With an Answering Machine Appendix E-Auxiliary Alert Option Installation InstructionsPage Figure E-1. Connections For Auxiliary Alert Device FCC Part FCC Regulations and Warranty Limited Warranty and Limitation of Liability Warranty InformationFCC Regulations and Warranty Memory AT&T Door Phone Controller Option SelectionDoor Phone Controller DIP Switch Settings1992 AT&T CIC# 0II722050-055 Issue 3, November