AT&T Door Phone Controller — Option Selection

To Select Options: (1) Set DIP switch location 8 to the ON position. (2) Dial door speaker phone number or extension. (3) Dial ##3. (4) Program any or all of the following functions, in any order:

Options

Mode Option/

Press

Listen

 

Press

Listen

Default

 

Verify

For

 

For

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Delay Before

To Select Option

00

Single

000 to 255 for 0 to 255

Double

30 sec.

 

Door Ajar

 

 

 

 

 

Beep

seconds of delay after strike

Beep

 

 

 

 

 

 

 

 

 

Call-back

To Verify

01

 

plate release stops until

 

 

 

 

 

 

 

 

 

 

Door Phone Controller calls

 

 

 

 

 

 

 

 

 

 

back to indicate that door is

 

 

 

 

 

 

 

 

 

 

ajar

 

 

 

 

 

Ring/Chime

To Select Option

10

Single

24 (for 2 sec. on 4 sec. off

Double

2 sec./

 

Cadence

 

 

 

 

Beep

cadence)

or

Beep

4 sec.

 

 

 

To Verify

11

 

 

 

 

 

 

15 (for 1 sec. on 5 sec. off

 

 

 

 

 

 

 

 

 

 

cadence)

 

 

 

 

 

 

 

 

 

 

 

 

 

Ring/Chime

To Select Option

20

Single

00 to 99 (0 to 99 second(s)

Double

30 sec.

 

Duration

 

 

 

 

Beep

ring/chime)

 

Beep

 

 

 

 

To Verify

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Door Unlock

To Select Option

30

Single

4 digits (first digit must be

Double

6736

 

Code

 

 

 

Beep

0,3,4,5,6,7 or 8;

Beep

“OPEN”

 

 

To Verify

31

 

 

 

 

 

 

remaining digits can be set

 

 

 

 

 

 

 

 

 

 

from 0 to 9)

 

 

 

 

 

 

 

 

 

 

 

Door Unlock

To Select Option

40

Single

00 to 99 (door lock active

Double

4 sec.

 

Duration

 

 

Beep

time in sec.)

Beep

 

 

To Verify

41

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enable Door

To Select Option

50

Single

1

Enable door code

Double

1

 

Code

 

 

Beep

0

Disable door code

Beep

(Enabled)

 

To Verify

51

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Door Ajar

To Select Option

50

Single

2

For callback after strike

Double

2

 

Mode

 

 

Beep

 

plate release only

Beep

 

 

 

 

 

 

 

 

 

 

 

To Verify

51

 

3

For callback anytime

 

 

 

 

 

 

 

 

 

 

 

door is opened

 

 

 

 

 

 

 

 

 

 

 

Forced

To Select Option

60

Single

010 to 255 (unit disconnects

Double

120 sec.

 

Disconnect

 

 

Beep

in 10 to 255 sec.)

Beep

 

 

To Verify

61

 

 

Time-Out

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reset Options

To Select Option

70

Single

## (to restore factory default

Double

N/A

 

to Factory

 

 

Beep

 

conditions)

Beep

 

 

To Verify

71

 

 

 

Defaults

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phone

To Select Option

80

Single

0 to 20 numerical digits and

Double

#

 

Number

 

 

Beep

( = 2 second pause) #

Beep

 

 

 

 

 

 

Storage

To Verify

81

 

terminates

entry

 

 

 

Memory 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Phone

To Select Option

90

Single

0 to 20 numerical digits and

Double

#

 

Number

 

 

Beep

( = 2 second pause) #

Beep

 

 

 

 

 

 

Storage

To Verify

91

 

terminates

entry

 

 

 

Memory 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

After Selecting Options: (1) Press ##3. (2) Hang up after hearing a double beep confirmation. (3) Set DIP location 8 back to the OFF position, to prevent unauthorized re-programming. (See other side for DIP Switch Settings.)

Image 96 Contents
AT&T Compatibility AT&T Door Phone Controller Compatibility Chart PlusApplication Notes for Compatibility Chart Application Notes for Compatibility Chart Contents Troubleshooting and Maintenance Page Figures Page Tables Introduction Using This Manual Features AT&T Door Phone ControllerSpeaker Volume Talk Back DIP Switch LED Terms You Should Know PBX Private Branch Exchange -Business telephoneInstallation Procedures Installation Procedures Important Safety Instructions Page General Information Introduction Door Phone Controller Back Panel ConnectionsPage Prior To Installation Door Phone Controller Back Panel ConnectionsAT&T Door Phone Controller Location Typical AT&T Door Phone Controller Installation Installation Mounting InstructionsWall Mount Instructions Mounting AT&T Door Phone Controller to Wall Remote Door Open Switch optional SHIELDED, Twisted PAIR, 24 AWG Connections for Remote Door Open Switch optional Electric Door Strike Plate Device optionalConnections for Electric Door Strike Plate optional Connecting Power Auxiliary Alert Device optionalConnections for Auxiliary Alert Device optional Installation Procedures Speaker Volume Control Talk Back Volume ControlOperation and Controls Information Door Ajar FunctionLED Configuration of Telephone Equipment Flow Chart Installation Home/Residential DIP Switch Selections OverviewHome/Residential DIP Switch Settings AT&T Door Phone Controller Back Panel Option Selection AT&T Door Phone Controller Option Selection Information Operation Basic Door Answer Function Visitor Presses Door Speaker ButtonAnswering a Call from the Door Speaker Calling the Door Speaker from Inside the Building Telephone Line In Use With Door When Incoming Call Arrives Installation Dedicated Trunk Port Overview DIP Switch Setting for PBX with Dedicated Trunk Port Telephone System 2b. Ground Start Installations Option Selection Page Options Mode Option Press Listen Default Verify For Calling the Door Speaker Installation for PBX Equipment With Available Station Port Overview G E ND Telephone System Option Selection Page Options Mode Option Listen Press Default Verify For Auxiliary Alert Mode Basic Door Answer Function Ringdown Mode Basic Door Answer FunctionOperation Opening door will terminate station mode access Installation No Dedicated Trunk/Station Port DIP Switch Selections DIP Switch Setting for PBX With Shared Trunk Port AT&T Door Phone Controller Back Panel Option Selection Port Saver or Trunk Saver Mode Installation Port Saver ModeTrunk Saver Mode Delay Operation Basic Door Answer Function Calling the Door Speaker From Inside the Building Telephone Line In Use With Door When a Call Arrives Placing a Call Through the C.O. From Inside BuildingTroubleshooting and Maintenance Troubleshooting Procedures Troubleshooting ProceduresWhen door ajar switch is not Maintenance Operating as ExpectedAppendix A-DIP Switch Settings Setting the DIP Switch PositionsNot used Appendix B-Option Selection Mode Definitions Ring/Chime Cadence Ring/Chime DurationPage Appendix C-Specifications ElectricalMechanical Ring Generator Line JackInstallation Information Using With an Answering Machine Installation Instructions Appendix E-Auxiliary Alert OptionPage Figure E-1. Connections For Auxiliary Alert Device FCC Part FCC Regulations and Warranty Warranty Information Limited Warranty and Limitation of LiabilityFCC Regulations and Warranty AT&T Door Phone Controller Option Selection MemoryDIP Switch Settings Door Phone Controller1992 AT&T CIC# 0II722050-055 Issue 3, November