Chapter 4: Field Settings

NOTE: The ‘After Scan’ rules are triggered by both a completed barcode scan as well as pressing the Down Arrow key on your PDA.

AccuScan Settings [After Scan]

Auto Submit

This option represents whether or not to automatically submit this record following an 'After Scan' event for this field. If this option is chosen for the selected field, the system automatically submits the record and sets the focus to the field selected in the Go To prompt for the selected field. The form is then ready for a new record.

Clear On Submit

This option is used to tell the system whether to clear the selected field after submitting the current record in the Entry screen. If the current record is submitted as a result of an ‘After Scan’ event or by clicking the Submit button, all the fields with this option selected are cleared. If the field has a Default Value, that value is used instead of a blank entry. Turning off Clear On Submit is especially useful if several records in a row will share a value for a field – it saves the user the time of re-entering the same data when entering several new records.

Auto Find on Scan

When Auto Find on Scan is selected, the database will search the session table for a record with a matching value in that field. If a matching value is found, the data entry screen is populated with that record data and the user is immediately put into edit mode. If a matching value is not found, a new record is created. The Auto Find on Scan is triggered when a barcode is scanned, or when the user presses the Down Arrow key after manually entering data in that field.

Update Variables

When this option is selected, Variable field data is updated to represent the time that the record was submitted as opposed to the default operation of using the time that the record was created. This is only relevant for date/time based variable settings, of course. This is useful when you want to track the date/time a record was edited, rather than created.

Go To

This option allows the user to control the tab order’ for the selected field. After a user performs a successful scan while in the focus of the selected field, the system sets the focus to whichever field is selected as the Go To Field. The user typically uses this feature to control the 'flow' of data entry. Alternatively, the Down Arrow key represents an 'After Scan' event for those PDAs that are not barcode enabled.

AccuScan PalmM-0002.010

24

Image 24
Contents AccuScan Palm / AccuScan Palm Pro Contents Setting Passwords Installation IntroductionFree Trial Learning AccuScan PalmIntegrating AccuScan Palm POS-X SupportInstallation Automatic InstallationInstalling AccuScan Palm on Multiple PDAs System RequirementsHow to Register Entering Your Registration CodeAccuScan Palm 2.0 Exists as a Separate Application Removing AccuScan Palm Installation New Registration Code Required New Location for Data FilesNew Location for Uploading Files New Name for List Upload FilesConfiguring Session Attributes SessionsSessions Select Session Settings Select the New button Session Settings ExplainedGeneral Session Settings Start On ScreenHotSync Settings Start On FieldEdit on scan/Find in grid Edit on Click in GridData Storage and Transfer Settings Backup Settings Append to Existing FileSend Non-Visible Fields Include Field NamesBackup Session Data Backup Drop-down ListsBackup Field Hints Deploying Configured Sessions to Multiple UsersField Settings Field SettingsConfiguring Field Settings Select Field Settings Field Settings Explained Field TypesText Drop-DownCheck Box VariableGeneral Field Settings INCR1,1Signature Pro Version Only Data Type Default General Numeric DateCancel VisibleShow in Grid Use Popup DialogValidation Field Settings After Scan Field SettingsUpdate Variables Auto SubmitClear On Submit Auto Find on ScanAllow PC Update Drop-Down ListsModify Field Settings Managing Data Managing DataQuick Buttons Finding Data Managing Data from the PDA to the PCHow Data Is Sent to the PC Viewing Data Files on the PCLinking AccuScan Palm Session Data to an MS Access Table Linking AccuScan Palm Data to an MS Excel WorksheetOdbc Link to Data File HotSyncing Data from the PC to the PDASending Session Data to the PDA \AccuScan Palm\Data\JohnSmith\ToPDACreating Session Data Files with Excel \Program Files \AccuScan Palm\Data\username\ToPDA\S01dataSending Drop-Down Lists to the PDA Sending Field Hints to the PDA Pro version onlyAdministration Settings Administration SettingsEnable Protection for How to Copy One PDA’s Configuration to Other PDAs File Names Used by AccuScan Palm