Symbol Technologies AccuScan Palm Pro user manual Sending Session Data to the PDA

Page 31

Chapter 5: Managing Data

5.5.1Sending Session Data to the PDA

All data prepared for upload to the PDA must be stored in a folder called ToPDA. This folder must be located under the AccuScan Palm\Data folder where AccuScan Palm was installed, and inside the folder for the current user. These folders are automatically created after HotSyncing. An example of what the data location of this folder might look like is C:\Program Files\POS-

X\AccuScan Palm\Data\JohnSmith\ToPDA.

Note: If you are using the Custom HotSync Folder feature (Pro version only), the ToPDA folder will be located in the Custom HotSync Folder you specified on the PDA under Session Settings

AccuScan Palm allows tab-delimited files to be sent from the PC to the PDA. The data file must be named exactly the same as the data generated by the HotSync process. So, for example, if you want to upload data for Session 2 on the PDA, the filename must be S02_data.txt and must be located in the ToPDA as described above.

The required file definition for sending session data from the PC to the PDA is as follows. <CR> indicates a carriage-return (line break), and <tab> indicates a tab character.

Field1<tab>Field2<tab>Field3<tab>….Field9<tab>Field10<CR>

Field1<tab>Field2<tab>Field3<tab>….Field9<tab>Field10<CR>

Below is a sample data file prepared for upload to a AccuScan Palm session.

A sample upload session file is located with this install. If you wish to test the functionality of this feature, simply place that sample file in the ToPDA subfolder and set its name to the appropriate session.

Note: If you define data for a session number that does not exist on the PDA, it will be ignored.

Note for New Users of Windows: Some versions of Windows will not display the file extension (e.g., “.txt”). On those systems, if you save a file as “S01_data.txt”, it will actually store the file as “S01_data.txt.txt” – and this file will not be recognized by AccuScan Palm. To check the actual name of a file you’ve created, right-click on it in Windows Explorer and choose “Properties”.

5.5.2Creating Session Data Files with Excel

To create a session data file with Excel, follow these steps.

1.Open the file in Excel

2.Select File from the Menu bar

3.Select Save As

4.In the Save As dialog box, select Save As Type: Text (Tab Delimited)

5.Save your session to

C:\Program Files \AccuScan Palm\Data\username\ToPDA\S01_data

Note: If you are using the Custom HotSync Folder setting, save the file to the Custom HotSync folder, under the \ToPDA folder.

AccuScan PalmM-0002.010

31

Image 31
Contents AccuScan Palm / AccuScan Palm Pro Contents Setting Passwords Introduction InstallationLearning AccuScan Palm Free TrialPOS-X Support Integrating AccuScan PalmSystem Requirements InstallationAutomatic Installation Installing AccuScan Palm on Multiple PDAsEntering Your Registration Code How to RegisterAccuScan Palm 2.0 Exists as a Separate Application New Name for List Upload Files Removing AccuScan Palm InstallationNew Registration Code Required New Location for Data Files New Location for Uploading FilesSessions Configuring Session AttributesSessions Start On Screen Select Session Settings Select the New buttonSession Settings Explained General Session SettingsEdit on Click in Grid HotSync SettingsStart On Field Edit on scan/Find in gridData Storage and Transfer Settings Include Field Names Backup SettingsAppend to Existing File Send Non-Visible FieldsDeploying Configured Sessions to Multiple Users Backup Session DataBackup Drop-down Lists Backup Field HintsField Settings Field SettingsConfiguring Field Settings Select Field Settings Drop-Down Field Settings ExplainedField Types TextVariable Check BoxData Type General Field SettingsINCR1,1 Signature Pro Version OnlyDate DefaultGeneral NumericUse Popup Dialog CancelVisible Show in GridAfter Scan Field Settings Validation Field SettingsAuto Find on Scan Update VariablesAuto Submit Clear On SubmitDrop-Down Lists Allow PC UpdateModify Field Settings Managing Data Managing DataQuick Buttons Viewing Data Files on the PC Finding DataManaging Data from the PDA to the PC How Data Is Sent to the PCHotSyncing Data from the PC to the PDA Linking AccuScan Palm Session Data to an MS Access TableLinking AccuScan Palm Data to an MS Excel Worksheet Odbc Link to Data File\Program Files \AccuScan Palm\Data\username\ToPDA\S01data Sending Session Data to the PDA\AccuScan Palm\Data\JohnSmith\ToPDA Creating Session Data Files with ExcelSending Field Hints to the PDA Pro version only Sending Drop-Down Lists to the PDAAdministration Settings Administration SettingsEnable Protection for File Names Used by AccuScan Palm How to Copy One PDA’s Configuration to Other PDAs