7.2.Default alarm messages
The default SIA messages for each PIN are shown below:
Pin | ‘Set’ message | ‘Restore’ message | Meaning |
|
|
|
|
1 | NBA01 | NBR01 | Burglary alarm/restore |
|
|
|
|
2 | NFA02 | NFR02 | Fire alarm/restore |
|
|
|
|
3 | NQA03 | NQR03 | Emergency alarm/restore |
|
|
|
|
4 | NOP04 | NCL04 | Open/close |
|
|
|
|
8.Relay outputs
The IRIS dialer has two relay outputs [20] that can be used in a number of ways:
•To indicate communications path failure.
•Activation by incoming SMS Message.
•Setting by the Monitoring Centre.
The relay contacts are normally open and closed when activated.
Wire to these contacts as required and define how they are to be used using the configuration options on the Settings Menu. See Appendix A for more details.
9.Troubleshooting
Problem | Resolution |
No screen display when IRIS | Check that there is power to the system |
dialer is connected to the | and that the wiring is the correct polarity. |
power. |
|
A fault develops and is | Touch the display and the instructions will |
indicated by the LED on the top | guide you through identification of the |
of the unit flashing. | problem. |
| Go to the Installers menu and select Test to |
| use the integrated test function. |
10 Iris Touch 200 Range Dialer Installation Manual