3.Alarm dialer interface

IRIS dialers carry alarm signals from the alarm panel over IP completely transparently so when they arrive at the Monitoring Centre it is as though they had come over a traditional PSTN connection. IRIS dialers support SIA (Levels 1 to 3), Contact ID, Scancom (Fast Format) and Robofon protocols, one of which virtually all alarm panels will support.

Apart from the following, no reconfiguration of the alarm panel is required for use with IRIS dialers:

1.If alarm signalling over Ethernet or GPRS is required, change the setting in the alarm panel for the telephone number to be dialled for alarm signalling. This number should be changed to the IP address of the Monitoring Centre, entered as 12 digits. Each of the four IP address numbers separated by a ‘.’ should be entered as a 3 digit number, with leading ‘0’s as required, and the ‘.’s should be excluded. For example:

IP address 10.1.146.22 is entered as 010001146022.

If the Monitoring Centre requires a backup IP address to be entered, this is done in the same way.

2.If alarm signalling over GSM is required, add a leading digit ‘7’ to the normal PSTN telephone number of the Monitoring Centre.

3.If the panel is required to make outgoing calls over IP for upload/download or remote configuration, then where the telephone number for this would normally be entered, put in the digit ‘8’ followed by the destination IP address in 12 digit format, as above.

4.Installing the IRIS Touch Dialer

Use the following procedure to install the IRIS Touch Dialer.

Note: For installations using PIN alarm inputs see the PIN alarms section for additional information and for wiring to relay outputs see the Relay outputs section.

Do not apply power to the dialer until indicated.

4 Iris Touch 200 Range Dialer Installation Manual

Image 9
Contents Range Dialer Installation Manual Page Page Contents Ii Iris Touch 200 Range Dialer Installation Manual Introduction About this manual…Overview Gprs System specificationsPackage contents Before you start…Pre-requisites Installing the Iris Touch Dialer Alarm dialer interfaceDecide where to run the cables Fit the SIM card GSM / Ethernet & Gprs only Configuring the Iris Touch Dialer PIN alarms Post installationInstallation Troubleshooting Default alarm messagesRelay outputs Setting Purpose Appendix a Settings menuAppendix B Installation photos Iris Touch 200 Range Dialer Installation Manual Alarm Dialer Interface Appendix C SpecificationConformance