Linear VMC-1 manual Door Station Rough-In, VMC1VDS Door Station Rough-in

Page 13

Door Station Rough-In

VMC1VDS Door Station Rough-in

The VMC1VDS is a metal door station with a 90 degree horizontal viewing area. It is normally mounted at a height from the floor of: 55” – 60”. When installing the VMC1VDS be aware of the camera location and the direction of sunlight and other ambient light. Direct sun or lighting into the lens of the VMC1VDS camera may impact the video quality. Additionally, exposure to extreme weather conditions is not recommended. For added protection against weather, the VMC1VDS should be equipped with a VDSWS-T weather shield. The installation of the VDSWS-T is shown in Figure 4.

NOTE: When removing allen screw from Video Door Station front bezel, a small metal tab will drop out of the chassis. Be sure to re-install tab into camera chassis slot before re-assembly.

1.Identify the location where the VMC1VDS is to be installed.

2.Pull Cat-5 wire from the VMC1MB to this location.

3.Label and tie off the wires so they do not fall back into the wall and are accessible when the VMC1VDS is installed.

4.If the door strike or Chime activated Control Output is to be utilized, see “Door Release Rough-in” and “Chime Activated CO Rough-in”.

PLEXIGLASS

WEATHER

SHIELD (OPTIONAL)

VDSWS-T

CAMERA

CHASSIS

VMC1VDS

BEZEL

ANCHORS

DRYWALL

4-1/2’ to 5’-0”

NOTE: METAL TAB

DROPS OUT WHEN

REMOVING ALLEN

SCREW HOLDING

FRONT BEZEL

TO CAMERA CHASSIS

MOUNTING HEIGHT FROM FLOOR LINE

ALLEN

SCREW

Figure 4. VMC1VDS Door Station Rough-In

11

Image 13
Contents VMC1 Shock Hazard Important DO’S & DON’TS Table of Contents Block Diagram Rough-in Kit IntroductionTools Materials RequiredOverview Cables and Wiring Wiring InformationMaximum Length for Cable Runs Cable Type and Configuration Master Station Rough-In VMC1MB Installation Unfinished Wall VMC1MB Master Station Mounting Bracket VMC1MB VMC1MB Installation Finished WallRoom Station Installation Finished Wall Room Station Installation Unfinished WallRoom Station Rough-In Room Station MountingVMC1VDS Door Station Rough-in Door Station Rough-InPOST-DRYWALL Color Video Door Station PRE-DRYWALL Color Video Door StationTE6D Power Supply Power Supply Rough-InPower Supply Connections PRE-WIRED Self Contained TE6D Power SupplyPower Identification AT Master Station Power Supply WiringPull Wires Data Hub WiringH628 Data Hub Radio Antennas Antenna InstallationAM Antenna FM AntennaDoor Release Rough-in Auxiliary Output Rough-InChime Activated Control Output Rough-In VMC1VDS DRWAppendix a Available Components Appendix a Available Components MLTL2DN49IR For more parts and accessories, please go to Year Limited Warranty