Auxiliary Output Rough-In
Door Release Rough-in
The Door Release Trigger can be activated from the VMC1 Master or any remote room station by pressing the Lock button. The Trigger will deactivate after 4 seconds and can be activated multiple times while the intercom is active.
To connect the optional Linear Model DRW Door Release Mechanism, refer to Figure 10 For controlling other door release devices, refer to the
1.Route a blue and a white 18 gauge wire from the Door Station location or VMC1MB to the optional 12V Model 284 relay. (See Appendix A). Following this color convention will assist in the final installation of the Door Station.
2.Connect the blue wire to the red coil wire on the 284 relay.
3.Connect the white wire to the white coil wire on the 284 relay.
4.Connect a red 18 gauge wire to the green Normally Open wire on the 284 relay.
5.Connect a red 18 gauge wire to the blue Common wire on the 284 relay.
6.Connect the other end of the red wire from the relay to the Yellow wire on the RT35 or either of the wires on the RT11.
7.Connect the other end of the red wire from the relay to one of the wires from the DRW.
8.Connect the remaining wire on the DRW to the Yellow/ Red wire on the RT35 or the remaining wire on the RT11.
9.Install the optional DRW into the door frame following the included instructions.
Chime Activated Control Output Rough-In
The Chime Activated Control Output allows for any number of security related automation functions including 10 available door chimes.To connect an auxiliary Chime refer to Figure 10. Refer to the
1.Route a blue and a black 18 gauge wire from the Door Station location or VMC1VDS to the optional 12V Model 284 relay. (See Appendix). Following this color convention will assist in the final installation of the Door Station.
2.Connect the blue wire to the red coil wire on the 284 relay.
3.Connect the black wire to the white coil wire on the 284 relay.
4.Connect a red 18 gauge wire to the green Normally Open wire on the 284 relay.
5.Connect a red 18 gauge wire to the blue Common wire on the 284 relay.
6.Connect the other end of the red wire from the relay to the Yellow wire on the RT35 or either of the wires on the RT11.
7.Connect the other end of the red wire from the relay to one of the wires from the Chime.
8.Connect the remaining wire on the Chime to the Yellow/ Red wire on the RT35 or the remaining wire on the RT11.
9.Install the optional Auxiliary Chime following its instructions.
VMC1VDS
DRW
MODEL DRW
ELECTRONIC DOOR STRIKE
OR CHIME
GRAY
DOOR
N/C NORMALLY CLOSED
STATION
BLUE
|
| COMMON | |
BLUE | RED | GREEN | |
NORMALLY OPEN | |||
|
| ||
WHITE | WHITE |
| |
BLACK | MODEL 284 |
| |
| 12V 5 AMP RELAY |
|
USE WHITE WIRE FOR DOOR RELEASE
USE BLACK WIRE FOR AUXILIARY CONTROL OUTPUT
110VAC 24VAC
MODEL RT11 OR RT35
Figure 10. Electric Door Strike Wiring
17