Power Supply Rough-In
Power Supply Wiring
1.Run a 14 AWG 120 VAC power cable (including ground) from a dedicated
2.Route incoming power cable into the Power Supply enclosure through the hole on the SIDE of the Power Supply.
3.Use wire nuts to connect the incoming power cable to the TE6D Power Supply BLACK (HOT) and WHITE (NEUTRAL) input wires.
4.Connect the GREEN (GROUND) wire to the ground conductor.
5.Secure all power cables entering the Power Supply enclosure with cable strain reliefs.
6.Tuck cables into the Power Supply enclosure.
7.Pull the Red and Black low voltage wires out of the top of the TE6D for later connection to the Master Station.
8.Hook the power supply onto the flange of the VMC1MB and attach the it with screw provided (See Figure 7).
✓NOTE: Be sure all power cables entering the power supply enclosure are secured with cable strain reliefs.
PRE-WIRED SELF CONTAINED TE6D POWER SUPPLY
GROUND WIRE (GREEN)
NEUTRAL WIRE (WHITE)
WIRE NUTS
INSERT
WIRE FROM
BREAKER INTO
STRAIN RELIEF
STRAIN RELIEF
FEED WIRES THROUGH
HOT WIRE (BLACK)
BOTTOM HOUSING
PLUS 13V WIRE (RED)
NEGATIVE WIRE (BLACK)
TOP HOUSING
STRAIN RELIEFS ON TOP HOUSING AS SHOWN. CONNECT WIRES USING WIRE NUTS, THEN
STRAIN RELIEF
POWER IDENTIFICATION
AT MASTER STATION
PLUS 13V
WIRE (RED)
NEGATIVE
WIRE (BLACK))
110/120V HIGH
VOLTAGE INPUT (BLACK)
SCREW (PROVIDED)
NEUTRAL (WHITE)
TE6D POWER SUPPLY
GROUND (GREEN)
Figure 7 - TE6D Power Supply Wiring