Add-on control unit (IS-SCU)
■Part names
CONTACT OUTPUT terminals
PA (Paging) OUTPUT terminals
|
| POWER switch |
|
| Turns the power ON ( ) or OFF ( ). |
|
| POWER LED (green) |
|
| Lights up when the power is ON. |
|
| POWER terminals |
MASTER STATION ports |
| STATUS LED (green) |
|
| |
| ID setting switch | Blinks when this unit is initialized or an error*1 |
VIDEO/AUDIO DOOR/SUB STATION ports | (→P.13) | occurs. |
|
| The LED will light up when this unit returns to |
Central control unit |
| the normal state. |
| *1: Communication error in a unit connected | |
|
| to this unit, or between this unit and a unit |
* No connection allowed. |
| connected to it, etc. |
VIDEO OUTPUT port 1 and port 2
NOTE:
The illustration of the unit may differ from the actual one.
■Specifications
Add-on control unit (IS-SCU)
Power source | 48V DC (supplied from the power supply unit) | |
Current consumption | Max. 1.2A | |
Ambient temperature | 0 - 40°C (+32°F - +104°F) | |
Talk channels・Video | Local system: 2 talk & 2 video channels, | |
channels | 1 chime | |
Master station(s) | Max. 8 | |
Video door station(s) |
| |
Audio door station(s) | Max. 8 | |
Room sub station(s) |
| |
Video output | NTSC | |
BNC (Video channel 1,2) | ||
| ||
Mounting | ||
Material | Steel plate | |
Color | Black |