Add-on control unit (IS-SCU)

Part names

CONTACT OUTPUT terminals

PA (Paging) OUTPUT terminals

 

 

POWER switch

 

 

Turns the power ON ( ) or OFF ( ).

 

 

POWER LED (green)

 

 

Lights up when the power is ON.

 

 

POWER terminals

MASTER STATION ports

 

STATUS LED (green)

 

 

 

ID setting switch

Blinks when this unit is initialized or an error*1

VIDEO/AUDIO DOOR/SUB STATION ports

(→P.13)

occurs.

 

 

The LED will light up when this unit returns to

Central control unit (IS-CCU) ports

 

the normal state.

 

*1: Communication error in a unit connected

 

 

to this unit, or between this unit and a unit

* No connection allowed.

 

connected to it, etc.

VIDEO OUTPUT port 1 and port 2

NOTE:

The illustration of the unit may differ from the actual one.

Specifications

Add-on control unit (IS-SCU)

Power source

48V DC (supplied from the power supply unit)

Current consumption

Max. 1.2A

Ambient temperature

0 - 40°C (+32°F - +104°F)

Talk channelsVideo

Local system: 2 talk & 2 video channels,

channels

1 chime

Master station(s)

Max. 8

Video door station(s)

 

Audio door station(s)

Max. 8

Room sub station(s)

 

Video output

NTSC

BNC (Video channel 1,2)

 

Mounting

Rack-mount (19-inch, 2U rack) or wall mount

Material

Steel plate

Color

Black

12

Image 12
Contents Installation Manual Contents About this ManualPrecautions Negligence could result in death or serious injurySystem Configurations System configuration examples Standard IP systemIP IP IP System connection diagram ConnectionsIP IP How to connect or disconnect stranded wires UsedAccessories Unit DetailsControl unit common information MountingPart names SpecificationsCentral control unit IS-CCU Connections BNCAdd-on control unit IS-SCU Refer to Output specifications →P.11 Room sub control unit IS-RCU Room sub control unit IS-RCUSet to this position when this unit is connected to IS-IPC IP control unit IS-IPC LAN Mounting When mounting on a wall Back wiringSurface wiring When mounting on a desktop stand Option wires to the unitConnect the CAT5e/6 cable Mounting locations IS-DV and IS-DVF Zoom pictureInstall the back box in the wall, Option wires to the unit withFasten the unit to Mounting surface Insert the transparent name plate. IS-DV and IS-DVFConnections IS-DV and IS-DVF Close it until it clicksConnections IS-SS Connect the CAT5e/6 cable and option wires to the unit Room sub station IS-RSC1 C30 Power supply unit IS-PU-UL and IS-PU-S Connect the power wiresAC cord requirements Plug in the AC cord securelyTechnical Data and Precautions Technical dataTechnical precautions Warranty FCC