Aiphone IS installation manual How to connect or disconnect stranded wires, Used

Page 8

Cables

Cables and connectors are not included with the products.

Refer to page 9 to 26 for details about each unit connection.

Notes on cables

Unless otherwise noted, never use individual

Odd number cables, such as

conductors, twisted pair cable or coaxial cable.

three conductor wire, cannot be

 

used.

Notes on CAT5e/6 cables

Do not bend the cables to an extent where the radius is less than 25 mm (1”). Communication failure could result.

CAT5e/6 cable

25mm (1") or more

Arrange the color code of the RJ45 connections in accordance with EIA/TIA-568A or 568B.

 

 

Pair2

 

 

Pair3

Pair3 Pair1 Pair4

 

Pair2 Pair1 Pair4

 

 

 

 

 

 

 

 

 

1 2 3 4 5 6 7 8

 

1 2 3 4 5 6 7 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CAT5e/6 cable

Less than 25mm (1")

Do not remove the CAT5e/6 cable jacket more than necessary.

T568AT568B

Be sure to check the condition of cable connections with a LAN checker before connecting with a LAN cable.

An RJ45 connector with a cover cannot be connected to the port for CAT5e/6 on master stations, door stations, or room sub stations. Use a cable without a cover for the units except for the control units.

Do not pull or put excess strain on CAT5e/6 cables.

Use a straight-through cable for connecting units. Use a crossover cable when connecting with a PC directly.

How to connect or disconnect stranded wires.

Twist the strands together, then insert the wire into one of the quick coupling terminals.

To ensure that the wire won't bend, press the release button while inserting into terminal.

 

e.g.) IS-CCU

e.g.) IS-MV (back)

Release button

 

8mm (3/8")

Release button

* Strip off the cable jacket by following the indication on each unit.

e.g.) IS-CCU

8

Image 8
Contents Installation Manual Contents About this ManualPrecautions Negligence could result in death or serious injurySystem Configurations IP IP IP System configuration examples Standard IP system System connection diagram ConnectionsIP IP How to connect or disconnect stranded wires UsedAccessories Unit DetailsControl unit common information MountingCentral control unit IS-CCU Part namesSpecifications Connections BNCAdd-on control unit IS-SCU Refer to Output specifications →P.11 Room sub control unit IS-RCU Room sub control unit IS-RCUSet to this position when this unit is connected to IS-IPC IP control unit IS-IPC LAN Surface wiring Mounting When mounting on a wallBack wiring Connect the CAT5e/6 cable When mounting on a desktop standOption wires to the unit Mounting locations IS-DV and IS-DVF Zoom pictureInstall the back box in the wall, Option wires to the unit withFasten the unit to Mounting surface Insert the transparent name plate. IS-DV and IS-DVFConnections IS-DV and IS-DVF Close it until it clicksConnections IS-SS Connect the CAT5e/6 cable and option wires to the unit Room sub station IS-RSC1 C30 Power supply unit IS-PU-UL and IS-PU-S Connect the power wiresAC cord requirements Plug in the AC cord securelyTechnical precautions Technical Data and PrecautionsTechnical data Warranty FCC