Cables
Cables and connectors are not included with the products.
Refer to page 9 to 26 for details about each unit connection.
Notes on cables
• Unless otherwise noted, never use individual | • Odd number cables, such as |
conductors, twisted pair cable or coaxial cable. | three conductor wire, cannot be |
| used. |
Notes on CAT5e/6 cables
•Do not bend the cables to an extent where the radius is less than 25 mm (1”). Communication failure could result.
CAT5e/6 cable
25mm (1") or more
•Arrange the color code of the RJ45 connections in accordance with
|
| Pair2 |
|
| Pair3 | ||
Pair3 Pair1 Pair4 |
| Pair2 Pair1 Pair4 | |||||
|
|
|
|
|
|
|
|
| 1 2 3 4 5 6 7 8 |
| 1 2 3 4 5 6 7 8 | ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
CAT5e/6 cable
Less than 25mm (1")
•Do not remove the CAT5e/6 cable jacket more than necessary.
T568AT568B
•Be sure to check the condition of cable connections with a LAN checker before connecting with a LAN cable.
•An RJ45 connector with a cover cannot be connected to the port for CAT5e/6 on master stations, door stations, or room sub stations. Use a cable without a cover for the units except for the control units.
•Do not pull or put excess strain on CAT5e/6 cables.
•Use a
How to connect or disconnect stranded wires.
•Twist the strands together, then insert the wire into one of the quick coupling terminals.
•To ensure that the wire won't bend, press the release button while inserting into terminal.
| e.g.) |
e.g.) | Release button |
|
8mm (3/8")
Release button
* Strip off the cable jacket by following the indication on each unit.
e.g.)
8