Pentair and P8, P4, PS8, PS4, PS6 installation manual Low Voltage Wiring Bezel Connection

Page 14

Page 14

3.3Low Voltage Wiring

3.3.1Bezel Connection

Plug the 24 VAC power plug from the transformer into its 3-pin terminal on the back of the Power Center PCB (see Figure 7). Mount the Bezel to the Power Center using the screws provided. Ensure that battery wires are kept from being pinched or damaged.

CAUTION

DO NOT INSTALL BATTERY until ready to power up system.

24 VAC Power Plug

Connection

Figure 7. Power Center PCB (back view)

3.3.2PDA J-Box Cable Connection to Power Center PCB

Make provision for the cable to be run between the PDA J-box and the Power Center. Never run high voltage and low voltage in the same conduit. Pull cable through the knockout with the Heyco fitting and into the low voltage compartment. Strip back jacket 6". Strip each wire a ¼" and connect to the red, 4-pin connector on the Power Center PCB. A multiplex kit may be required if there are more than two cables running to a red, 4-pin connector (see Figure 8).

NOTE For detailed tranceiver installation, see Section 3.7.1.

Low Voltage

Raceway

Conduit Knockout for Low Voltage

PDA J-box Wire

Heyco Fittings for Low Voltage JVA and Sensor Wires

High Voltage

Knockouts for

Conduit

(DO NOT run any Low Voltage wires through these knockouts)

Figure 8. PDA J-Box Cable Connection to Power Center PCB

Image 14 Contents
Installation Manual PDA Pool Digital Assistant Page Table of Contents Important Safety Instructions To Reduce the Risk of InjuryAvertissement Package Contents System OverviewService Switch System Component Specifications and DimensionsPower Supply Contact Rating RelaysBasic Plumbing Plumbing for Pool and Spa Combination Booster Pump Pool Cleaner Plumbing Non-Booster Pump Pool Cleaner Plumbing High Voltage Wiring System Power Installation Power Center Mounting Neutral2 3HP Standard Relays Bonding the Power Center Standard Power Center BondingUnderwater Lighting Gfci Wiring Gfci Installation for Underwater LightingVolt Jandy Pool and Spa Light Wiring Diagram Low Voltage Wiring Bezel Connection PDA J-Box Cable Connection to Power Center PCBTurn the heater switch to the on position Heater Connection Guidelines for Sophisticated DiagnosticSetting For dual thermostat heaters turn switch toHeater and Heat Pump/Chiller Wiring Outdoor Transceiver J-box Installation Temperature SensorsPDA Transceiver J-box Installation Jandy Valve ActuatorsPDA Handheld Remote Installation Changing the Frequency ChannelHandheld Remote Programming Basic Programming Menu Set slide switch on J-Box PCB toSystem Startup Label Auxiliary Functions Menu Set the Temperature MenuSet the Time Menu Set Freeze Protection Menu Assign JVAs MenuService Mode PDA System Defaults and General ModesPower Center Service Switch Auto Mode automatic Timeout ModeBattery Backup PDA Handheld Remote Menu Flow Chart Symptom Problem Possible Solution TroubleshootingPDA Quick Troubleshooting Guide Symptom Problem Possible Solution Power Center Wiring Diagram JVA JVAPower Center PCB DIP Switch Settings DIP Switch FunctionsDIP Switch # DIP Switch Settings for Pool and Spa CombinationFactory setting is with all DIP Switches off DIP Switch Settings for Pool or Spa Only General, Water Feature and Light Aux Labels General Labels Light Labels Waterfall LabelsLimited Warranty