4.2Restarting the System (Clear Memory) Menu

To remove all labeling, programming, assignments and temperature settings, highlight MENU and press SELECT. Highlight SYSTEM SETUP

and press SELECT (see Figure 30). Highlight CLEAR MEMORY and press SELECT. Highlight CONTINUE and press SELECT. Use the UP or DOWN button to highlight YES or NO and press SELECT. There will be about a 15 second delay before you see the FINISHED screen. Highlight CONTINUE and press SELECT to return to the

SYSTEM SETUP.

MAIN MENU

SYSTEM SETUP

HELP

SOLAR PRIORITY

PUMP LOCKOUT

PROGRAM

ASSIGN JVAs

SET TEMP

COLOR LIGHTS

SET TIME

SPA SWITCH

PDA OPTIONS

SERVICE INFO

SYSTEM SETUP

CLEAR MEMORY

 

HEAT PUMP

 

MORE

CLEAR MEMORY

CLEAR MEMORY

 

WARNING

FINAL WARNING

Are you SURE

Clearing memory

that you want to

ERASE ALL

erases ALL

SETTINGS

stored settings.

??

 

YES

CONTINUE

NO

 

CLEAR MEMORY

CLEAR MEMORY

ERASING

FINISHED

ALL

 

SETTINGS

Press SELECT

please wait

to continue.

 

CONTINUE

4.3PDA System Defaults and General Modes

Default Temperature (Pool/Spa Combination)

Default Pool Temp = 80° F

Default Spa Temp = 102° F

Default Temperature (Pool/Spa Only)

Default TEMP1 = 80° F

Default TEMP2 = 60° F

Default Spa Side Switch Settings

Button 1 = Spa (Filter Pump for pool/spa only models) Button 2 = Spa Heater (Temp1 pool/spa only models) Button 3 = AUX1

Button 4 = AUX2

Default Freeze Protection Settings

Filter Pump: Freeze Protection ON.

All Other Equipment: Freeze Protection OFF

Default Activation Temperature: 38° F

NOTE If you select SPA to be freeze protected, water circulation will switch between pool and spa every 30 minutes during freezing conditions once freeze mode is active.

4.3.1Power Center Service Switch

AUTO Mode (automatic)

1.The PDA Handheld Remote has complete control of all functions.

2.All programmed settings will operate.

3.All safety delays and equipment protection interlocks are operational.

SERVICE Mode

1.The power center has complete control of all functions.

2.Service mode must be turned on/off at the power center.

3.No programmed settings will work.

CAUTION

In service mode, equipment protection safety interlocks are overridden.

Figure 30. Clear Memory Menu

TIMEOUT Mode

 

1.

The power center has complete control for

 

 

three (3) hours.

 

2.

After three (3) hours the system will return

 

 

to AUTO mode.

 

3.

Programmed on/off times will be

 

 

overridden during the three (3) hours.

 

4.

After the three (3) hour "time out", the

 

 

system will resume any programmed items

 

 

that were overridden.

Image 22 Contents
Installation Manual PDA Pool Digital Assistant Page Table of Contents Important Safety Instructions To Reduce the Risk of InjuryAvertissement Package Contents System OverviewService Switch System Component Specifications and DimensionsPower Supply Contact Rating RelaysBasic Plumbing Plumbing for Pool and Spa Combination Booster Pump Pool Cleaner Plumbing Non-Booster Pump Pool Cleaner PlumbingHigh Voltage Wiring System Power InstallationPower Center Mounting Neutral2 3HP Standard Relays Bonding the Power Center Standard Power Center BondingUnderwater Lighting Gfci Wiring Gfci Installation for Underwater LightingVolt Jandy Pool and Spa Light Wiring Diagram Low Voltage Wiring Bezel Connection PDA J-Box Cable Connection to Power Center PCBTurn the heater switch to the on position Heater Connection Guidelines for Sophisticated DiagnosticSetting For dual thermostat heaters turn switch toHeater and Heat Pump/Chiller Wiring Outdoor Transceiver J-box Installation Temperature SensorsPDA Transceiver J-box Installation Jandy Valve Actuators PDA Handheld Remote Installation Changing the Frequency ChannelSystem Startup Set slide switch on J-Box PCB toHandheld Remote Programming Basic Programming Menu Set the Time Menu Set the Temperature MenuLabel Auxiliary Functions Menu Set Freeze Protection Menu Assign JVAs MenuService Mode PDA System Defaults and General ModesPower Center Service Switch Auto Mode automatic Timeout ModeBattery Backup PDA Handheld Remote Menu Flow Chart PDA Quick Troubleshooting Guide TroubleshootingSymptom Problem Possible Solution Symptom Problem Possible Solution Power Center Wiring Diagram JVA JVAPower Center PCB DIP Switch Settings DIP Switch FunctionsFactory setting is with all DIP Switches off DIP Switch Settings for Pool and Spa CombinationDIP Switch # DIP Switch Settings for Pool or Spa Only General, Water Feature and Light Aux Labels General Labels Light Labels Waterfall LabelsLimited Warranty