2.5 Information about the Other Cards
Connection Diagram for External Sensors and External Relays
Power to the external sensor is provided from the DPH4 card and must be grounded through the DPH4 card as indicated in the diagram below. A pair of "sensor" and "common" lines must be connected to the DPH4 card for each external sensor. The Hybrid
100Ω.
| sensor | 8 | |
Sensor 4 | common | ||
7 | |||
| sensor | ||
| 6 | ||
Sensor 3 | common | ||
5 | |||
| sensor | ||
| 4 | ||
Sensor 2 | common | ||
3 | |||
| sensor | ||
| 2 | ||
Sensor 1 | common | ||
1 | |||
|
|
5 V |
|
| 5 V |
|
|
|
|
|
|
|
| 33 Ω |
| 10K Ω |
|
|
|
|
|
|
|
| 2.2K |
|
|
|
|
|
|
|
| |
|
| 5 V |
|
| 5 V |
|
|
|
| |
|
|
|
|
|
|
|
|
| ||
| 33 Ω |
|
| 33 Ω |
| 10K Ω |
|
|
|
|
| 47K |
| 2.2K |
|
|
|
|
| ||
|
|
| 5 V |
| 5 V |
|
| |||
|
|
|
|
|
|
|
| |||
|
|
|
| 33 Ω |
| 33 Ω |
| 10K Ω |
|
|
|
|
|
|
| 2.2K |
|
|
| ||
|
|
|
| 47K |
| 5 V |
| 5 V | ||
|
|
|
|
|
|
| ||||
|
|
|
|
|
| 33 Ω |
|
| 33 Ω | 10K Ω |
|
|
|
|
|
| 47K |
| 2.2K | ||
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| 33 Ω | 47K |
|
|
|
|
|
|
|
|
|
|
10
9
8
7
6
5
4
3
2
1
Relay 4
Relay 3
Relay 2
Relay 1
Installation Manual
77