Panasonic KX-TDA30 installation manual Procedure Overview, Prepare the CS for site survey

Page 109

2.8 Connection of 2.4 GHz Portable Stations

2.8.2Procedure Overview

When connecting the wireless system, use extreme care to conduct a site survey. Inadvertent site survey can result in narrow service area, frequent noise, and disconnection of calls.

1. Investigate the installation site

Refer to "2.8.3 Site Planning".

a.Obtain the map of the CS installation site.

b.Consider the service area demanded by the user on the map.

c.Plan the locations of each CS, taking account of distance, building materials and etc.

2. Prepare the CS for site survey

Refer to "2.8.4 Before Site Survey".

a.Assign a CS number to each CS by setting the DIP switches on the back of the CS.

b.Supply electricity to each CS using an AC adaptor or a battery box.

c.Install each CS temporarily as planned.

Notes

Install at least 2 m above the floor.

Keep the antennas in the upright positions.

3.Conduct the site survey

Refer to "2.8.5 Site Survey".

a.Test the radio signal strength using the PS.

Confirm that the radio signal strength level is "12" near the CS.

1

9

Press 1, 9, and POWER for more than 2 seconds.

CS No.

1 to 9

Display example:

<< SEARCHING >>

CS NO.1 LEVEL:12

SAVE:0123456789

b.By walking away from the CS with the PS, check the radio signal strength. The radio signal strength weakens as you walk away from the CS.

c.Map the CS coverage area at radio signal strength levels "3" and "8".

d.Make sure that adjacent CS coverage areas overlap where the radio signal strength level is "8" by at least 5 m.

e.Make sure that the radio signal strength level is greater than "3" at any location within the service area demanded by the user.

4. Finish the site survey

Refer to "2.8.6 After Site Survey".

a.Return all DIP switches of each CS to the OFF position, and stop supplying electricity.

b.Turn off the PS.

Installation Manual 109

Image 109
Contents Model no. KX-TDA30 Hybrid IP-PBXTrunk Cards System Components Table Model Description Main UnitExtension Cards Other CardsAbbreviations in this manual Important Safety Instructions Installation Manual For users in New Zealand only For users in Germany onlyImportant Notice For users in Australia onlyFor your future reference Model No Serial NoHttp//doc.panasonic-tc.de About the Other Manuals Structure of this ManualTrademarks GREEN-AND-YELLOW Precautions for Users in the United KingdomInstallation Manual Table of Contents 128 108134 138Installation Manual Section System Outline System Highlights System HighlightsPC Phone/PC Console Features Main Unit Basic System ConstructionConstruction of Main Unit Hybrid IP-PBX System Connection DiagramDPT Options OptionsModel No Model Name Description Maximum Quantity EXT-CIDModel No Model Name Description Maximum Quantity General Description SpecificationsWeight when fully mounted DimensionExtension Connection Cable Characteristics Maximum Number of Cards for Each Slot System CapacityMaximum Terminal Equipment Adaptor only Adaptor and an Additional AC Adaptor Terminal Equipment TypeSLT+DPT+APT+CS+VM Specifications Section Installation Before Installation Before InstallationSafety Installation Instructions Installation PrecautionsBefore Installation Unpacking Installation of the Hybrid IP-PBXInside View Names and LocationsOpening the Covers Opening/Closing the CoversInstallation of the Hybrid IP-PBX Closing the Covers Installation of the Hybrid IP-PBX LED Indications Installation of the SD Memory CardColour Description Connect the frame of the Hybrid IP-PBX to earth Frame Earth ConnectionBackup Batteries Connection Installing Optional Service Cards Installing/Removing the Optional Service CardsSlot Condition Slot Type Card TypeInstallation of the Hybrid IP-PBX Removing the Optional Service Cards Connector Type Pin Number Used for Types of ConnectorsLCOT4 KX-TDA3180NE USB Wall Mounting KX-TDA30 Be careful not to drop the cabinet Wall Mounting AC Adaptor Reference for Wall Mounting Install a screw here 110 mmInstallation Lightning Protector InstallationOverview Recommended Lightning ProtectorsInstallation of an Earth Rod Outside InstallationNone Accessory and User-supplied Items Installation of the Trunk CardsUser-supplied not included RJ45 connector/RJ11 connector LCOT4 CardRJ11 Connector Pin Assignments RJ45 Connector Pin AssignmentsSignal Name Function 2 CID4 Card Accessory included none User-supplied not included noneUser-supplied not included RJ45 connector Switch Settings3 BRI2 Card RJ45 Connector for Extension Use RJ45 Connector for Trunk UsePin Assignments Line LED Flash PatternOFF Maximum Cabling Distance of S0 Bus ConnectionSignal Name Input I/Output O Function RJ45 Connector 10BASE-T/100BASE-TXIP-GW4 Card LED Indications 1 DLC4 Card Installation of the Extension CardsReserved Data port Low Volt Data port High Volt 2 SLC4 Card Reserved Tip Ring 3 DLC8 Card User-supplied not included RJ11 connectorRJ45 Connector Pin Assignments 4 SLC8 Card Reserved Tip Ring 1 DPH4 Card Installation of the Other CardsRJ11 Connector RJ45 ConnectorPin Terminal Block 2 DPH2 Card Pin Assignments Pin Terminal Block ECHO8 Card 4 MSG2 Card User-supplied none EXT-CID CardRMT Card Console Connection of ExtensionsInterface CS With APT Parallel Connection of the ExtensionsWith DPT With KX-T7600 Series DPT Extra Device Port XDP ConnectionWith Other DPTs except KX-T7560 and KX-T7565 DPT SLTConnection between two KX-T7600 Series DPTs except KX-T7640 Digital Extra Device Port Digital XDP ConnectionSLT Connection between KX-T7600 Series DPT except KX-T7640First Party Call Control CTI Connection Connection of Dect Portable Stations RF SpecificationOverview CS Cell Station KX-TDA0141CEEquipment Distance Investigate the installation site Procedure OverviewPrepare for site survey Conduct the site surveyMount the CS on the wall Site Planning Characteristics of Radio WavesUnderstanding the Radio Waves Object Material Transmission Tendency CS Coverage Area Radio Signal Strength LevelsSite Survey Preparation CS installation plan Example Installing in a Room Separated by WallsThings to take note Checking the CS ID Number Before Site SurveyAssigning the CS ID Number to the PS CS NoDIP Switch Setting and Installing the CS Temporarily for Site SurveyConnection of Dect Portable Stations Testing the Radio Signal Strength Site Survey Using the KX-TD7590Channel no Clearing the Stored Scan Data Referring the Stored Scan DataAfter Site Survey Accessory and User-supplied Items for the CS Connecting the Cell Station to the Hybrid IP-PBXConnecting the CS Registering the PS Administrator LevelUser Level Programming NoPS Registration 690PS Termination Changing the Display Language of the PSHandset PIN Testing the OperationWall Mounting Install a screw here 71 mm CS Cell Station KX-TDA0141 Connection of 2.4 GHz Portable StationsPS 2.4 GHz Portable Station KX-TD7690/KX-TD7680 Prepare the CS for site survey Mount the CS on the wall Site Planning Object Material Transmission Tendency CS Coverage Area Example Installing in a Room Separated by Walls CS Number Switch Radio Signal Test Switch CS no CS no CS no Connection of 2.4 GHz Portable Stations Scan Data No CS No Site SurveyPS CS NO.1 LEVEL12 Scan Data No Deleting the Stored Scan DataAfter Site Survey Connecting the Cell Station to the Hybrid IP-PBX Connecting the CS System Lock Password Entering the System Programming ModeSetting the PIN for Hybrid IP-PBX Setting the System LockSetting the PIN for PS 692If the registration information is still stored in the PS Wall Mounting Reference for Wall Mounting Connection of Doorphones and Door Openers Installing the Doorphone KX-T30865Connection of Doorphones and Door Openers Maximum Cabling DistanceConnection of Doorphones and Door Openers DP1/DP3 Connection of Doorphones to DPH4 Card with RJ45 ConnectorsConnection of Doorphones to DPH4 Card with RJ11 Connectors Connection of Door Openers to DPH4 Card DC1b/DC2b OP1b/OP2b DC1a/DC2a OP1a/OP2a Call1b/Call2b Connection of Peripherals Connection of PeripheralsBGM Pager Connection ChartsPC/Printer via RS-232C Pin AssignmentsRS-232C Signals For connecting printer/PC with a 25-pin RS-232C connectorSignal Ground SG Received Data RXD… inputVbus PC/Server PC via USB versionGND Auxiliary Connection for Power Failure Transfer Auxiliary Connection for Power Failure TransferUsing BRI Card RJ45 Connector Line 1 Pin Assignments Switch SettingsRJ45 Connector Line 2 Pin Assignments Switch Type Usage and Status DefinitionStarting the Hybrid IP-PBX Starting the Hybrid IP-PBXPower Switch Turning off the Hybrid IP-PBX Confirming the Trunk ConnectionSection Guide for the KX-TDA Maintenance Console Overview KX-TDA Maintenance Console*1Connection Modem Connection Using RMT CardConnection Serial Interface ConnectionRD RXD SD TXD DR DSR ER DTR External Modem ConnectionInstalling and Starting the KX-TDA Maintenance Console Installation of the KX-TDA Maintenance ConsolePassword Security System RequirementsInstallation of the KX-TDA Maintenance Console When country/area data do not match KX-TDA Maintenance Console KX-TDA Maintenance ConsoleInstallation of the KX-TDA Maintenance Console Menu Bar Structure of the KX-TDA Maintenance ConsoleHybrid IP-PBX Configuration Hybrid IP-PBX Maintenance Digital Trunk Error Report Error LogTimed Update System ResetSection Troubleshooting Installation TroubleshootingCause Trunk is connected to the T2/R1 Operation Problem Probable Cause Solution Operation Using the Reset ButtonTroubleshooting Error Log Display Format Troubleshooting by Error LogDescription Description Error Code Error Message List of Errors and SolutionsSLC, LCOT, BRI, IP MPR WDT System Start-up and On-line OperationMPR RAM Probable Cause Solution IP-GW ROM NGRAM NG MPR-LPR DLC Index Numerics Main Unit Index Reference for Wall Mounting Copyright PSQXxxxxZA KKxxxxx
Related manuals
Manual 76 pages 19.84 Kb Manual 200 pages 28.34 Kb

KX-TDA30 specifications

The Panasonic KX-TDA30 is a versatile and efficient hybrid telephone system designed to cater to the communication needs of small to medium-sized businesses. This advanced PBX (Private Branch Exchange) system integrates traditional analog telephony with digital and VoIP technologies, allowing organizations to create a unified communication environment that enhances productivity and collaboration.

One of the standout features of the KX-TDA30 is its scalability. The system supports up to 30 extensions and can easily expand as the business grows. This adaptability makes it an ideal solution for companies that anticipate future expansion. Additionally, with its modular design, users can seamlessly integrate various telephony options, including analog, digital, and IP phones.

The KX-TDA30 supports advanced call management features such as Caller ID, call forwarding, call waiting, and automated attendant services. These functionalities not only streamline communication but also enhance customer service by ensuring that calls are efficiently managed. The system’s built-in voicemail capabilities enable users to never miss important messages, allowing for enhanced communication both internally and externally.

Moreover, the Panasonic KX-TDA30 incorporates advanced technologies such as VoIP (Voice over Internet Protocol). By leveraging the internet for telephony services, businesses can significantly reduce calling costs, particularly for long-distance and international calls. The wealth of features that come with VoIP integration includes conferencing capabilities, which facilitate real-time collaboration among remote employees.

For ease of use, the KX-TDA30 features intuitive programming and installation processes. The system is equipped with a digital display that provides vital information and notifications, assisting users in navigating the various functionalities. The comprehensive user manuals and support from Panasonic help ensure a smooth setup and operation.

In terms of reliability, the KX-TDA30 offers robust performance with minimal downtime. It is built with high-quality components that ensure durability, making it a worthwhile investment for businesses. The system's energy-efficient design also contributes to lower operational costs, making it an environmentally friendly choice.

In summary, the Panasonic KX-TDA30 is a feature-rich hybrid telephone system that meets the diverse communication needs of modern businesses. Its scalability, advanced call management features, VoIP technology, and user-friendly design make it an excellent choice for organizations looking to enhance their communication infrastructure. With the KX-TDA30, companies can improve their operational efficiency, support growth, and elevate customer service experiences.