Panasonic KX-TDA30 installation manual RJ45 Connector, RJ11 Connector

Page 70

2.5 Installation of the Other Cards

Pin Assignments

RJ45 Connector

 

No.

Signal Name

Function

 

 

 

 

16

1-2

Reserved

 

 

 

3

DP2

Doorphone 2 transmit

 

 

 

 

 

9

4

DP1

Doorphone 1 transmit

 

 

 

 

8

5

com1

Doorphone 1 receive

 

 

 

6

com2

Doorphone 2 receive

 

 

 

 

 

1

7-

Reserved

 

10

 

 

 

 

 

 

 

11

DP4

Doorphone 4 transmit

 

 

 

 

 

12

DP3

Doorphone 3 transmit

 

 

 

 

 

13

com3

Doorphone 3 receive

 

 

 

 

 

14

com4

Doorphone 4 receive

 

 

 

 

 

15-

Reserved

 

16

 

 

 

 

 

 

RJ11 Connector

 

No.

Signal Name

Function

 

 

 

 

 

1

DP2

Doorphone 2 transmit

 

 

 

 

8

2

DP1

Doorphone 1 transmit

5

 

 

 

3

com1

Doorphone 1 receive

 

 

 

 

 

4

com2

Doorphone 2 receive

4

 

 

 

5

DP4

Doorphone 4 transmit

1

 

 

 

6

DP3

Doorphone 3 transmit

 

 

 

 

 

 

7

com3

Doorphone 3 receive

 

 

 

 

 

8

com4

Doorphone 4 receive

 

 

 

 

70

Installation Manual

Image 70
Contents Hybrid IP-PBX Model no. KX-TDA30Extension Cards System Components Table Model Description Main UnitTrunk Cards Other CardsAbbreviations in this manual Important Safety Instructions Installation Manual Important Notice For users in Germany onlyFor users in New Zealand only For users in Australia onlyModel No Serial No For your future referenceHttp//doc.panasonic-tc.de About the Other Manuals Structure of this ManualTrademarks Precautions for Users in the United Kingdom GREEN-AND-YELLOWInstallation Manual Table of Contents 134 108128 138Installation Manual Section System Outline System Highlights System HighlightsPC Phone/PC Console Features Main Unit Basic System ConstructionConstruction of Main Unit System Connection Diagram Hybrid IP-PBXDPT Model No Model Name Description Maximum Quantity OptionsOptions EXT-CIDModel No Model Name Description Maximum Quantity Specifications General DescriptionWeight when fully mounted DimensionExtension Connection Cable Characteristics Maximum Number of Cards for Each Slot System CapacityMaximum Terminal Equipment Adaptor only Adaptor and an Additional AC Adaptor Terminal Equipment TypeSLT+DPT+APT+CS+VM Specifications Section Installation Safety Installation Instructions Before InstallationBefore Installation Installation PrecautionsBefore Installation Installation of the Hybrid IP-PBX UnpackingNames and Locations Inside ViewOpening/Closing the Covers Opening the CoversInstallation of the Hybrid IP-PBX Closing the Covers Installation of the Hybrid IP-PBX LED Indications Installation of the SD Memory CardColour Description Frame Earth Connection Connect the frame of the Hybrid IP-PBX to earthBackup Batteries Connection Slot Condition Installing/Removing the Optional Service CardsInstalling Optional Service Cards Slot Type Card TypeInstallation of the Hybrid IP-PBX Removing the Optional Service Cards Connector Type Pin Number Used for Types of ConnectorsLCOT4 KX-TDA3180NE USB Wall Mounting KX-TDA30 Be careful not to drop the cabinet Wall Mounting AC Adaptor Install a screw here 110 mm Reference for Wall MountingOverview Lightning Protector InstallationInstallation Recommended Lightning ProtectorsOutside Installation Installation of an Earth RodNone User-supplied not included RJ45 connector/RJ11 connector Installation of the Trunk CardsAccessory and User-supplied Items LCOT4 CardRJ11 Connector Pin Assignments RJ45 Connector Pin AssignmentsSignal Name Function Accessory included none User-supplied not included none 2 CID4 CardUser-supplied not included RJ45 connector Switch Settings3 BRI2 Card Pin Assignments RJ45 Connector for Trunk UseRJ45 Connector for Extension Use Line LED Flash PatternMaximum Cabling Distance of S0 Bus Connection OFFSignal Name Input I/Output O Function RJ45 Connector 10BASE-T/100BASE-TXIP-GW4 Card LED Indications Installation of the Extension Cards 1 DLC4 CardReserved Data port Low Volt Data port High Volt 2 SLC4 Card Reserved Tip Ring User-supplied not included RJ11 connector 3 DLC8 CardRJ45 Connector Pin Assignments 4 SLC8 Card Reserved Tip Ring Installation of the Other Cards 1 DPH4 CardRJ45 Connector RJ11 ConnectorPin Terminal Block 2 DPH2 Card Pin Assignments Pin Terminal Block ECHO8 Card 4 MSG2 Card EXT-CID Card User-supplied noneRMT Card Console Connection of ExtensionsInterface CS With APT Parallel Connection of the ExtensionsWith DPT With Other DPTs except KX-T7560 and KX-T7565 Extra Device Port XDP ConnectionWith KX-T7600 Series DPT DPT SLTDigital Extra Device Port Digital XDP Connection Connection between two KX-T7600 Series DPTs except KX-T7640Connection between KX-T7600 Series DPT except KX-T7640 SLTFirst Party Call Control CTI Connection Overview RF SpecificationConnection of Dect Portable Stations CS Cell Station KX-TDA0141CEEquipment Distance Prepare for site survey Procedure OverviewInvestigate the installation site Conduct the site surveyMount the CS on the wall Site Planning Characteristics of Radio WavesUnderstanding the Radio Waves Object Material Transmission Tendency CS Coverage Area Radio Signal Strength LevelsSite Survey Preparation CS installation plan Example Installing in a Room Separated by WallsThings to take note Assigning the CS ID Number to the PS Before Site SurveyChecking the CS ID Number CS NoSetting and Installing the CS Temporarily for Site Survey DIP SwitchConnection of Dect Portable Stations Site Survey Using the KX-TD7590 Testing the Radio Signal StrengthChannel no Referring the Stored Scan Data Clearing the Stored Scan DataAfter Site Survey Connecting the Cell Station to the Hybrid IP-PBX Accessory and User-supplied Items for the CSConnecting the CS User Level Administrator LevelRegistering the PS Programming No690 PS RegistrationChanging the Display Language of the PS PS TerminationTesting the Operation Handset PINWall Mounting Install a screw here 71 mm CS Cell Station KX-TDA0141 Connection of 2.4 GHz Portable StationsPS 2.4 GHz Portable Station KX-TD7690/KX-TD7680 Prepare the CS for site survey Mount the CS on the wall Site Planning Object Material Transmission Tendency CS Coverage Area Example Installing in a Room Separated by Walls CS Number Switch Radio Signal Test Switch CS no CS no CS no Connection of 2.4 GHz Portable Stations Site Survey Scan Data No CS NoPS CS NO.1 LEVEL12 Deleting the Stored Scan Data Scan Data NoAfter Site Survey Connecting the Cell Station to the Hybrid IP-PBX Connecting the CS Entering the System Programming Mode System Lock PasswordSetting the PIN for PS Setting the System LockSetting the PIN for Hybrid IP-PBX 692If the registration information is still stored in the PS Wall Mounting Reference for Wall Mounting Connection of Doorphones and Door Openers Installing the Doorphone KX-T30865Connection of Doorphones and Door Openers Maximum Cabling DistanceConnection of Doorphones and Door Openers Connection of Doorphones to DPH4 Card with RJ45 Connectors DP1/DP3Connection of Doorphones to DPH4 Card with RJ11 Connectors Connection of Door Openers to DPH4 Card DC1b/DC2b OP1b/OP2b DC1a/DC2a OP1a/OP2a Call1b/Call2b Connection of Peripherals Connection of PeripheralsBGM PC/Printer via RS-232C Connection ChartsPager Pin AssignmentsSignal Ground SG For connecting printer/PC with a 25-pin RS-232C connectorRS-232C Signals Received Data RXD… inputVbus PC/Server PC via USB versionGND Auxiliary Connection for Power Failure Transfer Auxiliary Connection for Power Failure TransferUsing BRI Card RJ45 Connector Line 2 Pin Assignments Switch SettingsRJ45 Connector Line 1 Pin Assignments Switch Type Usage and Status DefinitionStarting the Hybrid IP-PBX Starting the Hybrid IP-PBXPower Switch Confirming the Trunk Connection Turning off the Hybrid IP-PBXSection Guide for the KX-TDA Maintenance Console KX-TDA Maintenance Console*1 OverviewConnection Modem Connection Using RMT CardConnection Serial Interface ConnectionExternal Modem Connection RD RXD SD TXD DR DSR ER DTRPassword Security Installation of the KX-TDA Maintenance ConsoleInstalling and Starting the KX-TDA Maintenance Console System RequirementsInstallation of the KX-TDA Maintenance Console KX-TDA Maintenance Console KX-TDA Maintenance Console When country/area data do not matchInstallation of the KX-TDA Maintenance Console Structure of the KX-TDA Maintenance Console Menu BarHybrid IP-PBX Configuration Hybrid IP-PBX Maintenance Timed Update Error LogDigital Trunk Error Report System ResetSection Troubleshooting Troubleshooting InstallationCause Trunk is connected to the T2/R1 Operation Problem Probable Cause Solution Using the Reset Button OperationTroubleshooting Error Log Display Format Troubleshooting by Error LogDescription Description Error Code Error Message List of Errors and SolutionsSLC, LCOT, BRI, IP MPR WDT System Start-up and On-line OperationMPR RAM Probable Cause Solution IP-GW ROM NGRAM NG MPR-LPR DLC Index Numerics Main Unit Index Reference for Wall Mounting Copyright PSQXxxxxZA KKxxxxx
Related manuals
Manual 76 pages 19.84 Kb Manual 200 pages 28.34 Kb

KX-TDA30 specifications

The Panasonic KX-TDA30 is a versatile and efficient hybrid telephone system designed to cater to the communication needs of small to medium-sized businesses. This advanced PBX (Private Branch Exchange) system integrates traditional analog telephony with digital and VoIP technologies, allowing organizations to create a unified communication environment that enhances productivity and collaboration.

One of the standout features of the KX-TDA30 is its scalability. The system supports up to 30 extensions and can easily expand as the business grows. This adaptability makes it an ideal solution for companies that anticipate future expansion. Additionally, with its modular design, users can seamlessly integrate various telephony options, including analog, digital, and IP phones.

The KX-TDA30 supports advanced call management features such as Caller ID, call forwarding, call waiting, and automated attendant services. These functionalities not only streamline communication but also enhance customer service by ensuring that calls are efficiently managed. The system’s built-in voicemail capabilities enable users to never miss important messages, allowing for enhanced communication both internally and externally.

Moreover, the Panasonic KX-TDA30 incorporates advanced technologies such as VoIP (Voice over Internet Protocol). By leveraging the internet for telephony services, businesses can significantly reduce calling costs, particularly for long-distance and international calls. The wealth of features that come with VoIP integration includes conferencing capabilities, which facilitate real-time collaboration among remote employees.

For ease of use, the KX-TDA30 features intuitive programming and installation processes. The system is equipped with a digital display that provides vital information and notifications, assisting users in navigating the various functionalities. The comprehensive user manuals and support from Panasonic help ensure a smooth setup and operation.

In terms of reliability, the KX-TDA30 offers robust performance with minimal downtime. It is built with high-quality components that ensure durability, making it a worthwhile investment for businesses. The system's energy-efficient design also contributes to lower operational costs, making it an environmentally friendly choice.

In summary, the Panasonic KX-TDA30 is a feature-rich hybrid telephone system that meets the diverse communication needs of modern businesses. Its scalability, advanced call management features, VoIP technology, and user-friendly design make it an excellent choice for organizations looking to enhance their communication infrastructure. With the KX-TDA30, companies can improve their operational efficiency, support growth, and elevate customer service experiences.