Panasonic KX-TDA30 installation manual Backup Batteries Connection

Page 40

2.2 Installation of the Hybrid IP-PBX

2.2.6Backup Batteries Connection

The backup batteries and Back-up Battery Cable provide backup power supply to allow full use of the Hybrid IP-PBX in the event of a power failure. In case of power failure, the backup batteries automatically maintain the power for the Hybrid IP-PBX without interruption.

Be sure to comply with applicable local regulations (e.g., law, guidelines).

1.Turn off the power switch of the Hybrid IP-PBX.

2.Connect the Back-up Battery Cable with 3 identical VRLA (Valve Regulated Lead Acid) batteries (12 V DC 3).

 

Battery Connector

 

Back-up Battery Cable

Fuse

 

 

Power Switch

Red

Black

Backup Batteries (12 V DC x 3)

Turn on the power switch of the Hybrid IP-PBX only after the installation of the Hybrid IP- PBX is finished and AC power is turned on.

For 1 backup battery, battery capacity of 28 Ah or below is recommended (otherwise, the backup battery may not be charged).

Make sure that the type and capacity of the 3 backup batteries are identical.

The Back-up Battery Cable should not be exposed to direct sunlight. Keep the Back-up Battery Cable and the backup batteries away from heating appliances and fire. Place the backup batteries in ventilated place.

For details about the backup batteries, refer to the manual intended for the batteries.

CAUTION

Make sure that the polarities of the backup batteries and wiring are correct.

Make sure that you do not short the backup batteries or cables.

There is a danger of explosion if backup batteries are incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions.

Use the correct type of Back-up Battery Cable.

40

Installation Manual

Image 40
Contents Hybrid IP-PBX Model no. KX-TDA30System Components Table Model Description Main Unit Trunk CardsExtension Cards Other CardsAbbreviations in this manual Important Safety Instructions Installation Manual For users in Germany only For users in New Zealand onlyImportant Notice For users in Australia onlyModel No Serial No For your future referenceHttp//doc.panasonic-tc.de About the Other Manuals Structure of this ManualTrademarks Precautions for Users in the United Kingdom GREEN-AND-YELLOWInstallation Manual Table of Contents 108 128134 138Installation Manual Section System Outline System Highlights System HighlightsPC Phone/PC Console Features Main Unit Basic System ConstructionConstruction of Main Unit System Connection Diagram Hybrid IP-PBXDPT Options OptionsModel No Model Name Description Maximum Quantity EXT-CIDModel No Model Name Description Maximum Quantity Specifications General DescriptionWeight when fully mounted DimensionExtension Connection Cable Characteristics Maximum Number of Cards for Each Slot System CapacityMaximum Terminal Equipment Adaptor only Adaptor and an Additional AC Adaptor Terminal Equipment TypeSLT+DPT+APT+CS+VM Specifications Section Installation Before Installation Before InstallationSafety Installation Instructions Installation PrecautionsBefore Installation Installation of the Hybrid IP-PBX UnpackingNames and Locations Inside ViewOpening/Closing the Covers Opening the CoversInstallation of the Hybrid IP-PBX Closing the Covers Installation of the Hybrid IP-PBX LED Indications Installation of the SD Memory CardColour Description Frame Earth Connection Connect the frame of the Hybrid IP-PBX to earthBackup Batteries Connection Installing/Removing the Optional Service Cards Installing Optional Service CardsSlot Condition Slot Type Card TypeInstallation of the Hybrid IP-PBX Removing the Optional Service Cards Connector Type Pin Number Used for Types of ConnectorsLCOT4 KX-TDA3180NE USB Wall Mounting KX-TDA30 Be careful not to drop the cabinet Wall Mounting AC Adaptor Install a screw here 110 mm Reference for Wall MountingLightning Protector Installation InstallationOverview Recommended Lightning ProtectorsOutside Installation Installation of an Earth RodNone Installation of the Trunk Cards Accessory and User-supplied ItemsUser-supplied not included RJ45 connector/RJ11 connector LCOT4 CardRJ11 Connector Pin Assignments RJ45 Connector Pin AssignmentsSignal Name Function Accessory included none User-supplied not included none 2 CID4 CardUser-supplied not included RJ45 connector Switch Settings3 BRI2 Card RJ45 Connector for Trunk Use RJ45 Connector for Extension UsePin Assignments Line LED Flash PatternMaximum Cabling Distance of S0 Bus Connection OFFSignal Name Input I/Output O Function RJ45 Connector 10BASE-T/100BASE-TXIP-GW4 Card LED Indications Installation of the Extension Cards 1 DLC4 CardReserved Data port Low Volt Data port High Volt 2 SLC4 Card Reserved Tip Ring User-supplied not included RJ11 connector 3 DLC8 CardRJ45 Connector Pin Assignments 4 SLC8 Card Reserved Tip Ring Installation of the Other Cards 1 DPH4 CardRJ45 Connector RJ11 ConnectorPin Terminal Block 2 DPH2 Card Pin Assignments Pin Terminal Block ECHO8 Card 4 MSG2 Card EXT-CID Card User-supplied noneRMT Card Console Connection of ExtensionsInterface CS With APT Parallel Connection of the ExtensionsWith DPT Extra Device Port XDP Connection With KX-T7600 Series DPTWith Other DPTs except KX-T7560 and KX-T7565 DPT SLTDigital Extra Device Port Digital XDP Connection Connection between two KX-T7600 Series DPTs except KX-T7640Connection between KX-T7600 Series DPT except KX-T7640 SLTFirst Party Call Control CTI Connection RF Specification Connection of Dect Portable StationsOverview CS Cell Station KX-TDA0141CEEquipment Distance Procedure Overview Investigate the installation sitePrepare for site survey Conduct the site surveyMount the CS on the wall Site Planning Characteristics of Radio WavesUnderstanding the Radio Waves Object Material Transmission Tendency CS Coverage Area Radio Signal Strength LevelsSite Survey Preparation CS installation plan Example Installing in a Room Separated by WallsThings to take note Before Site Survey Checking the CS ID NumberAssigning the CS ID Number to the PS CS NoSetting and Installing the CS Temporarily for Site Survey DIP SwitchConnection of Dect Portable Stations Site Survey Using the KX-TD7590 Testing the Radio Signal StrengthChannel no Referring the Stored Scan Data Clearing the Stored Scan DataAfter Site Survey Connecting the Cell Station to the Hybrid IP-PBX Accessory and User-supplied Items for the CSConnecting the CS Administrator Level Registering the PSUser Level Programming No690 PS RegistrationChanging the Display Language of the PS PS TerminationTesting the Operation Handset PINWall Mounting Install a screw here 71 mm CS Cell Station KX-TDA0141 Connection of 2.4 GHz Portable StationsPS 2.4 GHz Portable Station KX-TD7690/KX-TD7680 Prepare the CS for site survey Mount the CS on the wall Site Planning Object Material Transmission Tendency CS Coverage Area Example Installing in a Room Separated by Walls CS Number Switch Radio Signal Test Switch CS no CS no CS no Connection of 2.4 GHz Portable Stations Site Survey Scan Data No CS NoPS CS NO.1 LEVEL12 Deleting the Stored Scan Data Scan Data NoAfter Site Survey Connecting the Cell Station to the Hybrid IP-PBX Connecting the CS Entering the System Programming Mode System Lock PasswordSetting the System Lock Setting the PIN for Hybrid IP-PBXSetting the PIN for PS 692If the registration information is still stored in the PS Wall Mounting Reference for Wall Mounting Installing the Doorphone KX-T30865 Connection of Doorphones and Door OpenersConnection of Doorphones and Door Openers Maximum Cabling DistanceConnection of Doorphones and Door Openers Connection of Doorphones to DPH4 Card with RJ45 Connectors DP1/DP3Connection of Doorphones to DPH4 Card with RJ11 Connectors Connection of Door Openers to DPH4 Card DC1b/DC2b OP1b/OP2b DC1a/DC2a OP1a/OP2a Call1b/Call2b Connection of Peripherals Connection of PeripheralsBGM Connection Charts PagerPC/Printer via RS-232C Pin AssignmentsFor connecting printer/PC with a 25-pin RS-232C connector RS-232C SignalsSignal Ground SG Received Data RXD… inputVbus PC/Server PC via USB versionGND Auxiliary Connection for Power Failure Transfer Auxiliary Connection for Power Failure TransferUsing BRI Card Switch Settings RJ45 Connector Line 1 Pin AssignmentsRJ45 Connector Line 2 Pin Assignments Switch Type Usage and Status DefinitionStarting the Hybrid IP-PBX Starting the Hybrid IP-PBXPower Switch Confirming the Trunk Connection Turning off the Hybrid IP-PBXSection Guide for the KX-TDA Maintenance Console KX-TDA Maintenance Console*1 OverviewModem Connection Using RMT Card ConnectionConnection Serial Interface ConnectionExternal Modem Connection RD RXD SD TXD DR DSR ER DTRInstallation of the KX-TDA Maintenance Console Installing and Starting the KX-TDA Maintenance ConsolePassword Security System RequirementsInstallation of the KX-TDA Maintenance Console KX-TDA Maintenance Console KX-TDA Maintenance Console When country/area data do not matchInstallation of the KX-TDA Maintenance Console Structure of the KX-TDA Maintenance Console Menu BarHybrid IP-PBX Configuration Hybrid IP-PBX Maintenance Error Log Digital Trunk Error ReportTimed Update System ResetSection Troubleshooting Troubleshooting InstallationCause Trunk is connected to the T2/R1 Operation Problem Probable Cause Solution Using the Reset Button OperationTroubleshooting Error Log Display Format Troubleshooting by Error LogDescription Description Error Code Error Message List of Errors and SolutionsSLC, LCOT, BRI, IP MPR WDT System Start-up and On-line OperationMPR RAM Probable Cause Solution IP-GW ROM NGRAM NG MPR-LPR DLC Index Numerics Main Unit Index Reference for Wall Mounting Copyright PSQXxxxxZA KKxxxxx
Related manuals
Manual 76 pages 19.84 Kb Manual 200 pages 28.34 Kb

KX-TDA30 specifications

The Panasonic KX-TDA30 is a versatile and efficient hybrid telephone system designed to cater to the communication needs of small to medium-sized businesses. This advanced PBX (Private Branch Exchange) system integrates traditional analog telephony with digital and VoIP technologies, allowing organizations to create a unified communication environment that enhances productivity and collaboration.

One of the standout features of the KX-TDA30 is its scalability. The system supports up to 30 extensions and can easily expand as the business grows. This adaptability makes it an ideal solution for companies that anticipate future expansion. Additionally, with its modular design, users can seamlessly integrate various telephony options, including analog, digital, and IP phones.

The KX-TDA30 supports advanced call management features such as Caller ID, call forwarding, call waiting, and automated attendant services. These functionalities not only streamline communication but also enhance customer service by ensuring that calls are efficiently managed. The system’s built-in voicemail capabilities enable users to never miss important messages, allowing for enhanced communication both internally and externally.

Moreover, the Panasonic KX-TDA30 incorporates advanced technologies such as VoIP (Voice over Internet Protocol). By leveraging the internet for telephony services, businesses can significantly reduce calling costs, particularly for long-distance and international calls. The wealth of features that come with VoIP integration includes conferencing capabilities, which facilitate real-time collaboration among remote employees.

For ease of use, the KX-TDA30 features intuitive programming and installation processes. The system is equipped with a digital display that provides vital information and notifications, assisting users in navigating the various functionalities. The comprehensive user manuals and support from Panasonic help ensure a smooth setup and operation.

In terms of reliability, the KX-TDA30 offers robust performance with minimal downtime. It is built with high-quality components that ensure durability, making it a worthwhile investment for businesses. The system's energy-efficient design also contributes to lower operational costs, making it an environmentally friendly choice.

In summary, the Panasonic KX-TDA30 is a feature-rich hybrid telephone system that meets the diverse communication needs of modern businesses. Its scalability, advanced call management features, VoIP technology, and user-friendly design make it an excellent choice for organizations looking to enhance their communication infrastructure. With the KX-TDA30, companies can improve their operational efficiency, support growth, and elevate customer service experiences.