Panasonic KX-TDA30 Terminal Equipment Type, Adaptor only Adaptor and an Additional AC Adaptor

Page 27

 

 

 

1.4 Specifications

 

 

 

 

 

 

 

 

 

Terminal Equipment Type

With the Supplied AC

With the Supplied AC

 

 

Adaptor only

Adaptor and an

 

 

 

Additional AC Adaptor

 

 

 

 

 

SLT+DPT+APT+CS+VM

28*1

28*1

 

DPT (KX-T7200, KX-T7400)+APT+CS

8*1

24

*1 The maximum number of each terminal equipment is described above.

Installation Manual

27

Image 27
Contents Model no. KX-TDA30 Hybrid IP-PBXOther Cards System Components Table Model Description Main UnitTrunk Cards Extension CardsAbbreviations in this manual Important Safety Instructions Installation Manual For users in Australia only For users in Germany onlyFor users in New Zealand only Important NoticeFor your future reference Model No Serial NoHttp//doc.panasonic-tc.de Structure of this Manual About the Other ManualsTrademarks GREEN-AND-YELLOW Precautions for Users in the United KingdomInstallation Manual Table of Contents 138 108128 134Installation Manual Section System Outline System Highlights System HighlightsPC Phone/PC Console Features Basic System Construction Main UnitConstruction of Main Unit Hybrid IP-PBX System Connection DiagramDPT EXT-CID OptionsOptions Model No Model Name Description Maximum QuantityModel No Model Name Description Maximum Quantity General Description SpecificationsDimension Weight when fully mountedExtension Connection Cable Characteristics System Capacity Maximum Number of Cards for Each SlotMaximum Terminal Equipment Terminal Equipment Type Adaptor only Adaptor and an Additional AC AdaptorSLT+DPT+APT+CS+VM Specifications Section Installation Installation Precautions Before InstallationBefore Installation Safety Installation InstructionsBefore Installation Unpacking Installation of the Hybrid IP-PBXInside View Names and LocationsOpening the Covers Opening/Closing the CoversInstallation of the Hybrid IP-PBX Closing the Covers Installation of the Hybrid IP-PBX Installation of the SD Memory Card LED IndicationsColour Description Connect the frame of the Hybrid IP-PBX to earth Frame Earth ConnectionBackup Batteries Connection Slot Type Card Type Installing/Removing the Optional Service CardsInstalling Optional Service Cards Slot ConditionInstallation of the Hybrid IP-PBX Removing the Optional Service Cards Types of Connectors Connector Type Pin Number Used forLCOT4 KX-TDA3180NE USB Wall Mounting KX-TDA30 Be careful not to drop the cabinet Wall Mounting AC Adaptor Reference for Wall Mounting Install a screw here 110 mmRecommended Lightning Protectors Lightning Protector InstallationInstallation OverviewInstallation of an Earth Rod Outside InstallationNone LCOT4 Card Installation of the Trunk CardsAccessory and User-supplied Items User-supplied not included RJ45 connector/RJ11 connectorRJ45 Connector Pin Assignments RJ11 Connector Pin AssignmentsSignal Name Function 2 CID4 Card Accessory included none User-supplied not included noneSwitch Settings User-supplied not included RJ45 connector3 BRI2 Card Line LED Flash Pattern RJ45 Connector for Trunk UseRJ45 Connector for Extension Use Pin AssignmentsOFF Maximum Cabling Distance of S0 Bus ConnectionRJ45 Connector 10BASE-T/100BASE-TX Signal Name Input I/Output O FunctionIP-GW4 Card LED Indications 1 DLC4 Card Installation of the Extension CardsReserved Data port Low Volt Data port High Volt 2 SLC4 Card Reserved Tip Ring 3 DLC8 Card User-supplied not included RJ11 connectorRJ45 Connector Pin Assignments 4 SLC8 Card Reserved Tip Ring 1 DPH4 Card Installation of the Other CardsRJ11 Connector RJ45 ConnectorPin Terminal Block 2 DPH2 Card Pin Assignments Pin Terminal Block ECHO8 Card 4 MSG2 Card User-supplied none EXT-CID CardRMT Card Connection of Extensions ConsoleInterface CS Parallel Connection of the Extensions With APTWith DPT DPT SLT Extra Device Port XDP ConnectionWith KX-T7600 Series DPT With Other DPTs except KX-T7560 and KX-T7565Connection between two KX-T7600 Series DPTs except KX-T7640 Digital Extra Device Port Digital XDP ConnectionSLT Connection between KX-T7600 Series DPT except KX-T7640First Party Call Control CTI Connection CS Cell Station KX-TDA0141CE RF SpecificationConnection of Dect Portable Stations OverviewEquipment Distance Conduct the site survey Procedure OverviewInvestigate the installation site Prepare for site surveyMount the CS on the wall Characteristics of Radio Waves Site PlanningUnderstanding the Radio Waves Object Material Transmission Tendency Radio Signal Strength Levels CS Coverage AreaSite Survey Preparation Example Installing in a Room Separated by Walls CS installation planThings to take note CS No Before Site SurveyChecking the CS ID Number Assigning the CS ID Number to the PSDIP Switch Setting and Installing the CS Temporarily for Site SurveyConnection of Dect Portable Stations Testing the Radio Signal Strength Site Survey Using the KX-TD7590Channel no Clearing the Stored Scan Data Referring the Stored Scan DataAfter Site Survey Accessory and User-supplied Items for the CS Connecting the Cell Station to the Hybrid IP-PBXConnecting the CS Programming No Administrator LevelRegistering the PS User LevelPS Registration 690PS Termination Changing the Display Language of the PSHandset PIN Testing the OperationWall Mounting Install a screw here 71 mm Connection of 2.4 GHz Portable Stations CS Cell Station KX-TDA0141PS 2.4 GHz Portable Station KX-TD7690/KX-TD7680 Prepare the CS for site survey Mount the CS on the wall Site Planning Object Material Transmission Tendency CS Coverage Area Example Installing in a Room Separated by Walls CS Number Switch Radio Signal Test Switch CS no CS no CS no Connection of 2.4 GHz Portable Stations Scan Data No CS No Site SurveyPS CS NO.1 LEVEL12 Scan Data No Deleting the Stored Scan DataAfter Site Survey Connecting the Cell Station to the Hybrid IP-PBX Connecting the CS System Lock Password Entering the System Programming Mode692 Setting the System LockSetting the PIN for Hybrid IP-PBX Setting the PIN for PSIf the registration information is still stored in the PS Wall Mounting Reference for Wall Mounting Maximum Cabling Distance Installing the Doorphone KX-T30865Connection of Doorphones and Door Openers Connection of Doorphones and Door OpenersConnection of Doorphones and Door Openers DP1/DP3 Connection of Doorphones to DPH4 Card with RJ45 ConnectorsConnection of Doorphones to DPH4 Card with RJ11 Connectors Connection of Door Openers to DPH4 Card DC1b/DC2b OP1b/OP2b DC1a/DC2a OP1a/OP2a Call1b/Call2b Connection of Peripherals Connection of PeripheralsBGM Pin Assignments Connection ChartsPager PC/Printer via RS-232CReceived Data RXD… input For connecting printer/PC with a 25-pin RS-232C connectorRS-232C Signals Signal Ground SGPC/Server PC via USB version VbusGND Auxiliary Connection for Power Failure Transfer Auxiliary Connection for Power Failure TransferUsing BRI Card Switch Type Usage and Status Definition Switch SettingsRJ45 Connector Line 1 Pin Assignments RJ45 Connector Line 2 Pin AssignmentsStarting the Hybrid IP-PBX Starting the Hybrid IP-PBXPower Switch Turning off the Hybrid IP-PBX Confirming the Trunk ConnectionSection Guide for the KX-TDA Maintenance Console Overview KX-TDA Maintenance Console*1Serial Interface Connection Modem Connection Using RMT CardConnection ConnectionRD RXD SD TXD DR DSR ER DTR External Modem ConnectionSystem Requirements Installation of the KX-TDA Maintenance ConsoleInstalling and Starting the KX-TDA Maintenance Console Password SecurityInstallation of the KX-TDA Maintenance Console When country/area data do not match KX-TDA Maintenance Console KX-TDA Maintenance ConsoleInstallation of the KX-TDA Maintenance Console Menu Bar Structure of the KX-TDA Maintenance ConsoleHybrid IP-PBX Configuration Hybrid IP-PBX Maintenance System Reset Error LogDigital Trunk Error Report Timed UpdateSection Troubleshooting Installation TroubleshootingCause Trunk is connected to the T2/R1 Operation Problem Probable Cause Solution Operation Using the Reset ButtonTroubleshooting Troubleshooting by Error Log Error Log Display FormatDescription Description List of Errors and Solutions Error Code Error MessageSLC, LCOT, BRI, IP System Start-up and On-line Operation MPR WDTMPR RAM Probable Cause Solution ROM NG IP-GWRAM NG MPR-LPR DLC Index Numerics Main Unit Index Reference for Wall Mounting Copyright PSQXxxxxZA KKxxxxx
Related manuals
Manual 76 pages 19.84 Kb Manual 200 pages 28.34 Kb

KX-TDA30 specifications

The Panasonic KX-TDA30 is a versatile and efficient hybrid telephone system designed to cater to the communication needs of small to medium-sized businesses. This advanced PBX (Private Branch Exchange) system integrates traditional analog telephony with digital and VoIP technologies, allowing organizations to create a unified communication environment that enhances productivity and collaboration.

One of the standout features of the KX-TDA30 is its scalability. The system supports up to 30 extensions and can easily expand as the business grows. This adaptability makes it an ideal solution for companies that anticipate future expansion. Additionally, with its modular design, users can seamlessly integrate various telephony options, including analog, digital, and IP phones.

The KX-TDA30 supports advanced call management features such as Caller ID, call forwarding, call waiting, and automated attendant services. These functionalities not only streamline communication but also enhance customer service by ensuring that calls are efficiently managed. The system’s built-in voicemail capabilities enable users to never miss important messages, allowing for enhanced communication both internally and externally.

Moreover, the Panasonic KX-TDA30 incorporates advanced technologies such as VoIP (Voice over Internet Protocol). By leveraging the internet for telephony services, businesses can significantly reduce calling costs, particularly for long-distance and international calls. The wealth of features that come with VoIP integration includes conferencing capabilities, which facilitate real-time collaboration among remote employees.

For ease of use, the KX-TDA30 features intuitive programming and installation processes. The system is equipped with a digital display that provides vital information and notifications, assisting users in navigating the various functionalities. The comprehensive user manuals and support from Panasonic help ensure a smooth setup and operation.

In terms of reliability, the KX-TDA30 offers robust performance with minimal downtime. It is built with high-quality components that ensure durability, making it a worthwhile investment for businesses. The system's energy-efficient design also contributes to lower operational costs, making it an environmentally friendly choice.

In summary, the Panasonic KX-TDA30 is a feature-rich hybrid telephone system that meets the diverse communication needs of modern businesses. Its scalability, advanced call management features, VoIP technology, and user-friendly design make it an excellent choice for organizations looking to enhance their communication infrastructure. With the KX-TDA30, companies can improve their operational efficiency, support growth, and elevate customer service experiences.