Panasonic KX-TDA30 installation manual Important Safety Instructions

Page 4

Important Safety Instructions

SAFETY REQUIREMENTS

When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

1.Read and understand all instructions.

2.Follow all warnings and instructions marked on the product.

3.Unplug this product from the wall outlet before cleaning. Do not use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning.

4.Do not use this product near water, for example, near a bathtub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool.

5.Do not place this product on an unstable cart, stand, or table. The product may fall, causing serious damage to the product.

6.Slots and openings in the cabinet and the back or bottom are provided for ventilation; to protect it from overheating, these openings must not be blocked or covered. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface. This product should never be placed near or over a radiator or other heat source. This product should not be placed in a built-in installation unless proper ventilation is provided.

7.This product should be operated only from the type of power source indicated on the product label. If you are not sure of the type of power supply to your home, consult your dealer or local power company.

8.This product is equipped with a 3-wire earthing type plug, a plug having a third (earthing) pin. This plug will only fit into an earthing type power outlet. This is a safety feature. If you are unable to insert the plug into the outlet, contact your electrician to replace your obsolete outlet. Do not defeat the safety purpose of the earthing type plug.

9.Do not allow anything to rest on the power cord. Do not locate this product where the cord will be abused by people walking on it.

10.Do not overload wall outlets and extension cords as this can result in the risk of fire or electric shock.

11.Never push objects of any kind into this product through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a risk of fire or electric shock. Never spill liquid of any kind on the product.

12.To reduce the risk of electric shock, do not disassemble this product, but take it to a qualified person when some service or repair work is required. Opening or removing covers may expose you to dangerous voltages or other risks. Incorrect reassembly can cause electric shock when the appliance is subsequently used.

13.Unplug this product from the wall outlet and refer servicing to qualified service personnel under the following conditions:

a)When the power supply cord or plug is damaged or frayed.

b)If liquid has been spilled into the product.

c)If the product has been exposed to rain or water.

d)If the product does not operate normally by following the operating instructions. Adjust only those controls that are covered by the operating instructions because improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the product to normal operation.

e)If the product has been dropped or the cabinet has been damaged.

4

Installation Manual

Image 4
Contents Hybrid IP-PBX Model no. KX-TDA30System Components Table Model Description Main Unit Trunk CardsExtension Cards Other CardsAbbreviations in this manual Important Safety Instructions Installation Manual For users in Germany only For users in New Zealand onlyImportant Notice For users in Australia onlyModel No Serial No For your future referenceHttp//doc.panasonic-tc.de About the Other Manuals Structure of this ManualTrademarks Precautions for Users in the United Kingdom GREEN-AND-YELLOWInstallation Manual Table of Contents 108 128134 138Installation Manual Section System Outline System Highlights System HighlightsPC Phone/PC Console Features Main Unit Basic System ConstructionConstruction of Main Unit System Connection Diagram Hybrid IP-PBXDPT Options OptionsModel No Model Name Description Maximum Quantity EXT-CIDModel No Model Name Description Maximum Quantity Specifications General DescriptionWeight when fully mounted DimensionExtension Connection Cable Characteristics Maximum Number of Cards for Each Slot System CapacityMaximum Terminal Equipment Adaptor only Adaptor and an Additional AC Adaptor Terminal Equipment TypeSLT+DPT+APT+CS+VM Specifications Section Installation Before Installation Before InstallationSafety Installation Instructions Installation PrecautionsBefore Installation Installation of the Hybrid IP-PBX UnpackingNames and Locations Inside ViewOpening/Closing the Covers Opening the CoversInstallation of the Hybrid IP-PBX Closing the Covers Installation of the Hybrid IP-PBX LED Indications Installation of the SD Memory CardColour Description Frame Earth Connection Connect the frame of the Hybrid IP-PBX to earthBackup Batteries Connection Installing/Removing the Optional Service Cards Installing Optional Service CardsSlot Condition Slot Type Card TypeInstallation of the Hybrid IP-PBX Removing the Optional Service Cards Connector Type Pin Number Used for Types of ConnectorsLCOT4 KX-TDA3180NE USB Wall Mounting KX-TDA30 Be careful not to drop the cabinet Wall Mounting AC Adaptor Install a screw here 110 mm Reference for Wall MountingLightning Protector Installation InstallationOverview Recommended Lightning ProtectorsOutside Installation Installation of an Earth RodNone Installation of the Trunk Cards Accessory and User-supplied ItemsUser-supplied not included RJ45 connector/RJ11 connector LCOT4 CardRJ11 Connector Pin Assignments RJ45 Connector Pin AssignmentsSignal Name Function Accessory included none User-supplied not included none 2 CID4 CardUser-supplied not included RJ45 connector Switch Settings3 BRI2 Card RJ45 Connector for Trunk Use RJ45 Connector for Extension UsePin Assignments Line LED Flash PatternMaximum Cabling Distance of S0 Bus Connection OFFSignal Name Input I/Output O Function RJ45 Connector 10BASE-T/100BASE-TXIP-GW4 Card LED Indications Installation of the Extension Cards 1 DLC4 CardReserved Data port Low Volt Data port High Volt 2 SLC4 Card Reserved Tip Ring User-supplied not included RJ11 connector 3 DLC8 CardRJ45 Connector Pin Assignments 4 SLC8 Card Reserved Tip Ring Installation of the Other Cards 1 DPH4 CardRJ45 Connector RJ11 ConnectorPin Terminal Block 2 DPH2 Card Pin Assignments Pin Terminal Block ECHO8 Card 4 MSG2 Card EXT-CID Card User-supplied noneRMT Card Console Connection of ExtensionsInterface CS With APT Parallel Connection of the ExtensionsWith DPT Extra Device Port XDP Connection With KX-T7600 Series DPTWith Other DPTs except KX-T7560 and KX-T7565 DPT SLTDigital Extra Device Port Digital XDP Connection Connection between two KX-T7600 Series DPTs except KX-T7640Connection between KX-T7600 Series DPT except KX-T7640 SLTFirst Party Call Control CTI Connection RF Specification Connection of Dect Portable StationsOverview CS Cell Station KX-TDA0141CEEquipment Distance Procedure Overview Investigate the installation sitePrepare for site survey Conduct the site surveyMount the CS on the wall Site Planning Characteristics of Radio WavesUnderstanding the Radio Waves Object Material Transmission Tendency CS Coverage Area Radio Signal Strength LevelsSite Survey Preparation CS installation plan Example Installing in a Room Separated by WallsThings to take note Before Site Survey Checking the CS ID NumberAssigning the CS ID Number to the PS CS NoSetting and Installing the CS Temporarily for Site Survey DIP SwitchConnection of Dect Portable Stations Site Survey Using the KX-TD7590 Testing the Radio Signal StrengthChannel no Referring the Stored Scan Data Clearing the Stored Scan DataAfter Site Survey Connecting the Cell Station to the Hybrid IP-PBX Accessory and User-supplied Items for the CSConnecting the CS Administrator Level Registering the PSUser Level Programming No690 PS RegistrationChanging the Display Language of the PS PS TerminationTesting the Operation Handset PINWall Mounting Install a screw here 71 mm CS Cell Station KX-TDA0141 Connection of 2.4 GHz Portable StationsPS 2.4 GHz Portable Station KX-TD7690/KX-TD7680 Prepare the CS for site survey Mount the CS on the wall Site Planning Object Material Transmission Tendency CS Coverage Area Example Installing in a Room Separated by Walls CS Number Switch Radio Signal Test Switch CS no CS no CS no Connection of 2.4 GHz Portable Stations Site Survey Scan Data No CS NoPS CS NO.1 LEVEL12 Deleting the Stored Scan Data Scan Data NoAfter Site Survey Connecting the Cell Station to the Hybrid IP-PBX Connecting the CS Entering the System Programming Mode System Lock PasswordSetting the System Lock Setting the PIN for Hybrid IP-PBXSetting the PIN for PS 692If the registration information is still stored in the PS Wall Mounting Reference for Wall Mounting Installing the Doorphone KX-T30865 Connection of Doorphones and Door OpenersConnection of Doorphones and Door Openers Maximum Cabling DistanceConnection of Doorphones and Door Openers Connection of Doorphones to DPH4 Card with RJ45 Connectors DP1/DP3Connection of Doorphones to DPH4 Card with RJ11 Connectors Connection of Door Openers to DPH4 Card DC1b/DC2b OP1b/OP2b DC1a/DC2a OP1a/OP2a Call1b/Call2b Connection of Peripherals Connection of PeripheralsBGM Connection Charts PagerPC/Printer via RS-232C Pin AssignmentsFor connecting printer/PC with a 25-pin RS-232C connector RS-232C SignalsSignal Ground SG Received Data RXD… inputVbus PC/Server PC via USB versionGND Auxiliary Connection for Power Failure Transfer Auxiliary Connection for Power Failure TransferUsing BRI Card Switch Settings RJ45 Connector Line 1 Pin AssignmentsRJ45 Connector Line 2 Pin Assignments Switch Type Usage and Status DefinitionStarting the Hybrid IP-PBX Starting the Hybrid IP-PBXPower Switch Confirming the Trunk Connection Turning off the Hybrid IP-PBXSection Guide for the KX-TDA Maintenance Console KX-TDA Maintenance Console*1 OverviewModem Connection Using RMT Card ConnectionConnection Serial Interface ConnectionExternal Modem Connection RD RXD SD TXD DR DSR ER DTRInstallation of the KX-TDA Maintenance Console Installing and Starting the KX-TDA Maintenance ConsolePassword Security System RequirementsInstallation of the KX-TDA Maintenance Console KX-TDA Maintenance Console KX-TDA Maintenance Console When country/area data do not matchInstallation of the KX-TDA Maintenance Console Structure of the KX-TDA Maintenance Console Menu BarHybrid IP-PBX Configuration Hybrid IP-PBX Maintenance Error Log Digital Trunk Error ReportTimed Update System ResetSection Troubleshooting Troubleshooting InstallationCause Trunk is connected to the T2/R1 Operation Problem Probable Cause Solution Using the Reset Button OperationTroubleshooting Error Log Display Format Troubleshooting by Error LogDescription Description Error Code Error Message List of Errors and SolutionsSLC, LCOT, BRI, IP MPR WDT System Start-up and On-line OperationMPR RAM Probable Cause Solution IP-GW ROM NGRAM NG MPR-LPR DLC Index Numerics Main Unit Index Reference for Wall Mounting Copyright PSQXxxxxZA KKxxxxx
Related manuals
Manual 76 pages 19.84 Kb Manual 200 pages 28.34 Kb

KX-TDA30 specifications

The Panasonic KX-TDA30 is a versatile and efficient hybrid telephone system designed to cater to the communication needs of small to medium-sized businesses. This advanced PBX (Private Branch Exchange) system integrates traditional analog telephony with digital and VoIP technologies, allowing organizations to create a unified communication environment that enhances productivity and collaboration.

One of the standout features of the KX-TDA30 is its scalability. The system supports up to 30 extensions and can easily expand as the business grows. This adaptability makes it an ideal solution for companies that anticipate future expansion. Additionally, with its modular design, users can seamlessly integrate various telephony options, including analog, digital, and IP phones.

The KX-TDA30 supports advanced call management features such as Caller ID, call forwarding, call waiting, and automated attendant services. These functionalities not only streamline communication but also enhance customer service by ensuring that calls are efficiently managed. The system’s built-in voicemail capabilities enable users to never miss important messages, allowing for enhanced communication both internally and externally.

Moreover, the Panasonic KX-TDA30 incorporates advanced technologies such as VoIP (Voice over Internet Protocol). By leveraging the internet for telephony services, businesses can significantly reduce calling costs, particularly for long-distance and international calls. The wealth of features that come with VoIP integration includes conferencing capabilities, which facilitate real-time collaboration among remote employees.

For ease of use, the KX-TDA30 features intuitive programming and installation processes. The system is equipped with a digital display that provides vital information and notifications, assisting users in navigating the various functionalities. The comprehensive user manuals and support from Panasonic help ensure a smooth setup and operation.

In terms of reliability, the KX-TDA30 offers robust performance with minimal downtime. It is built with high-quality components that ensure durability, making it a worthwhile investment for businesses. The system's energy-efficient design also contributes to lower operational costs, making it an environmentally friendly choice.

In summary, the Panasonic KX-TDA30 is a feature-rich hybrid telephone system that meets the diverse communication needs of modern businesses. Its scalability, advanced call management features, VoIP technology, and user-friendly design make it an excellent choice for organizations looking to enhance their communication infrastructure. With the KX-TDA30, companies can improve their operational efficiency, support growth, and elevate customer service experiences.