Linear AE-500 manual 94#000000#000000#, System Utilities

Page 14

System Utilities

Several utility commands are available for the system. Utilities can be used to clear memory, display system information, and control the relays.

Display Unit Number

In multi-unit installations the unit number of each AE-500 can be displayed.

1.If not already in Programming Mode, use the local keypad to enter the master password and access programming.

2.Press

3. The display will show the unit number for three seconds.

4. Exit Programming Mode if all programming is complete.

Display System Firmware Version

The version of the fi rmware installed in the system can be displayed.

1.If not already in Programming Mode, use the local keypad to enter the master password and access programming.

2.Press

3. The display will show the fi rmware version.

4. Exit Programming Mode if all programming is complete.

Manual Control of the Relays

For servicing or testing, each relay output can be controlled manually from the local keypad while in Programming Mode.

1.If not already in Programming Mode, use the local keypad to enter the master password and access programming.

2.Enter a command to control a relay:

Press to latch Relay Channel “A”.

Press to latch Relay Channel “B”.

Press to release Relay Channel “A”.

Press to release Relay Channel “B”.

3. The display will show the unit number for three seconds.

4. Exit Programming Mode if all programming is complete.

Deleting Database Entries

Sections of the database can be deleted individually. Exercise care when using these commands, their effect cannot be reversed.

1.If not already in Programming Mode, connect by telephone or use the local keypad. Enter the master password and access programming.

2.Enter a command to delete database sections:

To delete all resident data:

To delete all entry codes press:

To delete all wireless transmitters press:

3. Exit Programming Mode if all programming is complete.

DISPLAY UNIT NUMBER

PPN 72

72#

 

 

 

 

 

DISPLAY SYSTEM FIRMWARE VERSION

PPN 73

73#

 

 

 

 

 

LATCH RELAY CHANNEL "A"

PPN 81

81#

 

 

 

 

 

LATCH RELAY CHANNEL "B"

PPN 82

82#

 

 

 

 

 

RELEASE RELAY CHANNEL "A"

PPN 83

83#

 

 

 

 

 

RELEASE RELAY CHANNEL "B"

PPN 84

84#

 

 

 

 

 

DELETE ALL RESIDENT DATA

PPN 92

92#000000#000000#

 

 

 

 

DELETE ALL ENTRY CODES

PPN 93

93#000000#000000#

 

 

 

 

DELETE ALL WIRELESS TRANSMITTERS

PPN 94

94#000000#000000#

14

Image 14
Contents AE-500 Operation ContentsIntroduction Database OverviewSystem Features Programming with a Computer 71#UNIT# Setting up Multiple UnitsPress Enter the unit number Exit Programming Mode Le and click Upload to send the fi le to the unitProgramming Over the Telephone Programming from the Local KeypadData Restore Factory SettingsData Backup Programming Reference22#DIR#NAME#PHONE# 02#LENGTH#21#DIR#NAME#PHONE# 23#DIR#DIR#Entry Code Programming 03#LENGTH#33#CODE#CODE# 45#FC#ID# Wireless Transmitter Programming41#NUMBER#FC#ID# 43#FC#ID#Activate a Transmitter 42#FC#ID#47#FC#ID# Delete single Enrolled Transmitter57#LINE 1#LINE 2# 51#COUNT#58#KEY#ACTION# 62#CHIRP#65#POS# 63#TONE#64#TIME# 94#000000#000000# System UtilitiesRequesting Access with a Visitor Call Requesting Access with an Entry CodeRequesting Access with a Wireless Transmitter Resident can use their telephone’s keypad to grant accessTroubleshooting