Panasonic AJ-SD930BE Reel Rota VTR Stop TOO Fast, Torque ERR VTR Stop, CAP Tension, Reel DIR

Page 70

CONTENTS

Error messages

Error messages

Display

ODescription

 

 

 

OVTR operation and corrective action

 

 

 

 

 

 

 

E-64

If the supply reel motor speed is abnormally

 

high, the error number flashes on the display.

S REEL ROTA

VTR: STOP

 

 

 

TOO FAST

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-67

If the take-up reel motor speed is abnormally

 

high, the error number flashes on the display.

T REEL ROTA

VTR: STOP

 

 

 

TOO FAST

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-69

If excess torque being applied to the take-up

 

reel motor is detected, the error number flashes

T REEL

on the display.

 

 

 

TORQUE ERR

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-70

If excess torque being applied to the supply reel

 

motor is detected or an abnormal current flowing

S REEL

to the current detection resistor is detected, this

TORQUE ERR

error number flashes on the display.

 

 

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-71

If abnormal tension at the supply side is

 

detected in the capstan mode, the error number

CAP TENSION

flashes on the display.

 

 

ERROR

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-72

If abnormal tension at the supply side is

 

detected in the reel mode, the error number

REEL

flashes on the display.

 

 

TENSION

VTR: STOP

 

 

 

ERROR

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-73

If the take-up reel motor has rotated in the

 

reverse direction, this error number flashes on

REEL DIR

the display.

 

 

 

UNMATCH

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-74

If excess torque being applied to the cylinder

 

motor is detected, this error number flashes on

DRUM

the display.

 

 

 

TORQUE

VTR: STOP

 

 

 

ERROR

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

E-78

If a problem has been encountered in

 

communication

between

the

servo

M-IF COMM

microcomputer and mechanism relay board, this

ERROR

error number flashes on the display.

 

 

VTR: STOP

 

 

 

 

OSet the POWER switch to OFF and then to

 

ON again.

 

 

 

 

 

 

 

 

Consult your dealer if the error message is still displayed even after restarting the unit.

70 (E)

Image 70
Contents Operating Instructions Model No. AJ- EContents For U.K. only$ this Apparatus Must be Earthed Operating precaution$ do not Remove Panel Cover by Unscrewing Contents IntroductionFeatures Parts and their functions Front panelStop button Play buttonREC button FF buttonJOG PlayerRecorder ShtlPreview ReviewUnity REC LEVEL, PB LevelVAR OFF PresetRegen EXTDisplay panel REC Edit RECREC INH IN/OUT Rear panelOUT Cmonitor OUT connectors Parallel Remote connectorAnalog Audio OUT connectors = Signal GND terminalRecorder ConnectionsSource machine OFFRecorder AV monitor AV monitor Reference signal GeneratorConnections with editing controller Editing controllerCassettes TapesConsumer-use DV and Dvcam cassettes Cassette sizeJog mode Jog/ShuttleAssemble Manual editing SD955BPreroll SD955B InsertWhen using the AJ-SD955B as the player Switch settings and adjustmentsWhen using the AJ-SD955B as the recorder Automatic editing deck-to-deckSD955BAssem Selecting the editing modeMatch frame processing function How to calculate the duration Checking and previewing edit pointsModifying edit points Re-registering an edit pointRetry function Executing and reviewing automatic editingPost-rolling Auto tag function recorder sideAudio split editing SD955B Between the audio in and OUT points $ Duration displayBetween the video in and OUT points Match frame processing system$ Releasing variable memory mode Variable memory editing operation procedure$ Selecting the variable memory mode Variable memory editing SD955BChanging the settings Setup initial settingsChanging the file Setup menusSetting and releasing the lock mode SystemLoad/save Lock mode can be set Counter displayLoading user files Menu screenSaving user files System menu SYS SC/H SET UP LevelOffset LocalUser menu BasicChara Type Chara H-POSChara V-POS SYS FormatOperation Memory stop function Eject SW REC INHLamp INHInterface Edit AUD Edit Edit RplcecConfi Edit AUD Edit OUTTape Protect Time Code SBC RUN ModeVitc OUT VauxOUT Vsync YC SEP ModeINT SG Mute SELSetup ESR ModeCCR Mode CmpstWide Select CC RECUmid REC INT Umid GENUmid POS CH3 in LV CH1 in LVCH2 in LV CH4 in LVREC CH1 Moni CH SELPCM REC CH2User menu Audio REC LINE1 BlankADD Line REC LINE2REC LINE4 REC LINE3Teletext SEL Number of lines which can be set for Teletext Menu Time code Setting the internal time codeTime code/user bit User bitLTC Setting the external time codeVitc Characters displayed Operation modeSuperimpose screen Display positionExternal synchronization of video output signals Video output signals and servo reference signalInternal synchronization Servo reference signal Audio V fade function Audio signal aFade is performed instantaneously to eliminate the noise Audio recording channel Audio recording channel and monitor output selectionPrinted circuit board Monitor output channelRack-mounting adaptors Rack mountingStandard rack Fasten it to the rack with set screws Condensation Video head cleaningMaintenance Attaching the dust cover$ Displaying the Diag menu Error messagesDiag menu $ Warning information display$ Displaying the Hours Meter information $ Umid information displayInvalid Video SIG High Error RateUnknown SIG Invalid Audio SIGError messages Reel Rota VTR Stop TOO Fast Tension VTR Stop ErrorTorque VTR Stop Error ReelConnector specifications Hardware specificationsExternal interface specifications RS-232C interfaceCommunication parameters Software specifications ProtocolSend format controller PC 5 VTR $ When the communication has terminated normally Error code tableReturn format VTR 5 controller PC Command table $ Commands relating to operation controlRequest $ Commands relating to inquiriesCTL/TC Data STX QCD ETX Status STX QOP ETXSdti interface Precautions to observe when using the Sdti signalsConnections involving two units Remote IN/OUT Connector signalsRemote OUT RS-232C SUB 25-pin crossover cable supported$Digital video Specifications$Video input connector $Digital IN/Analogue component OUT$Audio input connector $Video output connector$Video signal adjustment $Audio output connectorPanasonic Broadcast Europe Panasonic Broadcast Europe GmbH