Roland AR-200 Procedure, Important Notes on, Making Connections, Switching the Power On

Page 22

Recording Audio

Procedure

1

2

Make the correct connections, then turn on the power switch.

 

"Important Notes on

 

Making Connections and

Insert a formatted card into one of the slots.

Switching the Power On

 

and Off" (P.9)

Press the [ ] or [ ] button to select the number of the phrase to be recorded.

The non-recording phrase number in display is flashed.

fig.rec-05

*If you are re-recording over a previously recorded phrase, you should delete the phrase. (p. 26)

*You cannot change the phrase number after recording, so be sure to select the phrase number you want to record.

3

Hold down the STOP button and press the PLAY button to go

 

 

into recording standby.

The PLAY indicator is flashed while the recording standby mode.

4

Input the sounds from the device connected to the input jacks,

 

 

then use the input volume knob to adjust the recording level

 

so that the MIDI/CLIP indicator does not light.

Nominal Input level:0 dBm

Maximum input level: +2.5 dBu

*If signals louder than +2.5 dBu are being input, rotate the input volume knob to the left of center.

*Press the STOP button and recording standby mode will end.

22

Image 22
Contents Page Using the Unit Safely Page Maintenance Power SupplyPlacement Before Using PC CardsContents Midi Implementation Midi Implementation Chart Specification Troubleshooting Error messages Regarding CardsMode SW Settings AppendicesMain Features Rear panel Panel DescriptionsFront panel Bottom chassisTurning On the Power Refer also to DC power supply pAttaching the Rubber Feet Included Items InstallationRack Mounting Important Notes on Heat Radiation Attaching the Card Protector InstallationRack-Mounting the AR-200 Examples of Usage and Connection for the AR-200 Using the Control Input and Output ConnectorsDevice with the AR-200 Control Output Connectors p Together with Other Equipment System ExamplesControlling the AR-200 With Midi Signals Midi Control p Using the Midi ConnectorsExamples of Usage and Connection for the AR-200 Repeat Playback of the Same Phrase What You Can Do Usage TipsPlaying a Variety of Phrases in Succession Card Storage Times and Number of Phrases Cards Handled by the AR-200Types of Usable Cards Formatting a CardImportant Notes on Handling Cards Procedure for Formatting CardsCards Handled by the AR-200 If You’re Using a Legacy Model Card Compatibility with Other Models in the AR SeriesRecording Units-Phrases Connecting External DevicesRecording Audio Monitor Output During Recording and Recording StandbyRecording Audio Procedure for RecordingRDAC-Gradesampling frequency REC Mode SW-3 Amount of cardRDAC-Mode Signal Processing FormatREC Mode SW 4 Card Audio Recording Time Chart P.53What is mono recording Recording Type Stereo/MonoREC Mode SWLine Thru Output Important Notes on ProcedureSwitching the Power On Making ConnectionsChecking What You Recorded Information Recorded on the CardPlayback Using the Panel Manual Playback Press the Play button and the phrase will playbackDeleting Single Phrases Deleting PhrasesDeleting All Phrases Recording and Playing Midi Data Midi Phrase What is a Midi Phrase?Procedure for Recording Midi PhrasesRecording and Playing Midi Data Midi Phrase Procedure for Playing Back MidiPlayback Using Control Input and Other Input Manual playbackPlayback By Card Data Selecting the Control Input Mode AR-200 SettingsAssigning Phrases to the Terminals Basic Operation of Direct Playback Reverse Priority Operational Specifications for Direct Playback Last-InOperational Specifications for Control Input Playback Priority OrderConnectors Used in Binary Playback What Is Binary Playback?/Use and ApplicationsSpecifying Phrases in Binary Notation Binary Playback To Specify Phrases with Binary Signals Operational Specifications of Binary PlaybackBasic Operation of Binary Playback Phrase Number / Binary Signal chart Repeated Playback of Phrases Interval Playback Operational Specifications of Interval PlaybackWhat is Terminal Rec/Use and Applications Basic Operation of Interval PlaybackConnectors Used in Terminal Rec Connecting EquipmentOperational Specifications for Terminal Rec Presence or Absence of PhrasesPlayback Switching the Terminal Recording ModeErase 001 00000000 Output of Busy Out Signals In Dual Mono Mode p What is the Busy Out Signal?/ Connecting DevicesImportant Note on Using the Control Input and Output Ports Starting Another Device Busy OutOutput of Control Out Signals In Dual Mono Mode p What is the Control Out Signal? Connecting DevicesControlling Another Device Control Out Memo Applications Guide Playback of Phrases Using Midi Signals Controlling the AR-200 with Midi Signals Midi controlWhat is Midi Control?/What You Can Do Using Midi Control When Playing Back Midi Phrases Using Midi Signals Controlling the AR-200 with Midi Signals Midi controlAssignment of Phrases to Note Numbers Midi Note Map Procedure for Making the Midi Receive Channel Settings Midi Receive channel Settings Midi channelMidi Control Signals That Can Be Received Receive Messages Midi Note OutExample of Connecting to an Playback with AR-LINK SignalsWhat is AR-LINK?/What You Can Do Using AR-LINK Synchronized Audio PhraseSettings Procedure Selecting the AR-200’s Operation AROther Useful Functions During Phrase Playback Line Out Thru Setting During Phrase PlaybackTo Users of the AR-2000/100 Legacy Models Line Thru Output Specifications Other Useful Functions During Phrase PlaybackAppendices About playback TroubleshootingAbout recording About playback and recording of Midi phrasesOthers TroubleshootingCard made on the AR-3000 Error messages Fig.er-3Card Audio Recording Time Chart Regarding CardsRecorded Phrase Data Settings When a Card Is FormattedAppendices Midi settings AR-3000 settings that can be usedAR-LINK Setting Mode SW Settings Mode Switch SpecificationsControl I/O Connector specifications DC power supplyControl Change Midi ImplementationReceive data Media Player Section Program ChangeMidi Time Code Midi ImplementationMidi Machine Control MMC Transmitted message which are produced Transmitted message which are receivedRecognized message for sync Message not memorized during recording Exclusive Communication Messages received for detecting trouble in Midi connectionTransmit data Midi Recorder Section Parameter Address MapExclusive Address Table Phrase Select AR-200/3000 Midi Implementation Midi Recording Section Specification Specification Input/Output Standard DimentionsIndex AR-LINKInformation AfricaAvis 02235223 ’03-8-7N