Marantz PMD570 manual RS-232C connector, Using serial communication, a, Host device can control

Page 23
Wiring diagram
7. REMOTE1 jack REMOTE1 accepts a remote (not supplied) that connects via a TS 1/4 inch plug.

Back continued

6

7

8

 

 

R

BALANCED

IN

L

ANALOG

DIGITAL

 

 

 

 

 

UL US LISTED

AC

IN

 

 

GROUND

 

 

 

L

 

 

 

 

 

 

 

MODEL NO. PMD570

 

2

3

1

 

 

 

 

IN

I / O

REMOTE2

RS 232C

REMOTE1

C

 

HOT (+)

 

COLD (-)

 

 

 

 

 

 

 

AUDIO SYSTEM

AC120V 60HZ 0.5A

 

 

 

 

 

 

 

 

 

 

 

 

 

69 FM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MADE IN JAPAN

 

 

 

+ 24

+ 24

 

 

 

OUT

 

 

 

C A U T I O N

 

SERIAL

NO .

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

OUT

(SPDIF)

 

 

 

RISK OF ELECTRIC SHOCK

WARNING: SHOCK HAZARD- DO NOT OPEN.

 

 

 

 

REF=+16dBu/0dBFS

 

 

 

 

DO NOT OPEN

AVIS: RISQUE DE CHOC ELECTRIQUE-NE PAS OUVRIR.

 

 

 

 

 

 

 

 

 

 

 

 

RS 232C

6. RS-232C connector

 

 

Using serial communication, a

 

host device can control the

 

PMD570.

The RS-232C host can control functions of the PMD570 externally.

The PMD570 automatically transmits status data when status is changed.

The PMD570 will respond to a status request by transmitting the associated status data.

See RS-232C control, page 47, for details.

With Marantz Professional's PMD570 control setup application (check the enclosed CD ROM or see www.d-mpro.com to download) you can control the PMD570 from your PC. See page 46 for a brief description of the application.

REMOTE1

A connected switch on closing and on

opening does the following depending

on the Remote Menu setting.

Remote Menu setting:

StartPause

Close to start open to pause during recording or playback. If Auto Mark is ON and EDL mark is added when recording resumes.

StrtPausTR

Close to start, open to pause during recording or playback. Start after a record pause, continues on the next track.

EDL Mark

During record or playback close to add an EDL mark.

Manual TRK

During recording, close to increment the track. A new track is created at that point. There is no break in recording.

REMOTE1 behavior depending on switching activity:

 

 

 

 

 

 

 

 

Remote Menu setting

 

 

 

 

 

 

 

 

 

StartPause

 

StrtPausTR

 

EDL Mark

 

Manual TRK

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

open

 

 

 

closed

Start

 

Start

 

add

 

create

 

 

 

 

 

 

next track

 

EDL mark

 

new track

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

closed

 

 

open

Pause

 

Pause

 

-

 

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AC IN

8. AC IN

Connect the 3 prong AC power cord.

CAUTION:

Only use the supplied power cord.

Menu mode

Presets

Three menu selectable Presets make it easy to switch between commonly used input, recording setup, and playback conditions. Called Preset1, Preset2, and Preset3.

How to switch Presets

From stop, push and release the MENU/STORE button to enter Menu mode.

The currently selected Preset (1, 2 or 3) will be displayed and flashing.

 

TIME

 

 

 

 

 

 

 

 

REC REMAIN

L

 

 

 

 

 

 

 

 

 

-dB

00

 

40

20

12

6

2

0 over

 

R

 

 

 

 

 

 

 

-dB

 

 

 

 

 

 

 

 

 

 

 

LINE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Turn the Jog Wheel to scroll through Presets 1, 2 and 3. Push and release the Jog Wheel to select the displayed Preset.

The Input menu for the selected Preset will be displayed.

You can edit the menu for the chosen Preset.

To accept the menu settings, push and release the MENU/STORE button. The display returns to stop.

- 23 -

Image 23
Contents Model PMD570 User Guide Risk of Electric Shock Important Safety Instructions Copyright CE marking only EU version English Edit Menu Table of ContentsEditing and setup Package contents Audio inputs may be from SetupIntroduction Computer compatibleEDL marks FeaturesTracks Copy audio files to or from your 6a. Connect RC600 wiredConnect line level XLR equipment for recording This connection makes it easy toStart-up Recording setupInitialize Example Power ON/OFF buttonTurn to adjust headphone VolumeTo eject a CF card CF card access light greenCF card compartment Card eject buttonAlternate information displays Default display Is elapsed time onDefault display is 5a. Display buttonRemain label REC labelTotal label Track labelRecord icon Mark labelLower alphanumeric display Line labelCurrently How to change PresetsSelected Preset 7a. MenuJog Wheel Example displayWith level margin at 02dB beforeHow to adjust record balance How to select tracks during playbackHow to select an EDL mark How to adjust record levelShift button How to start a new trackHow to add an EDL mark while recording Stop/CANCEL buttonPin 1 ground BackAt stop Trim L & RO port Connectors SpdifDigital OUT jack RCA Analog OUT jacksMenu mode Presets RS-232C connectorUsing serial communication, a Remote Menu setting StartPausePCM/MP2/MP3 Table of Preset defaultsHow to select inputs for recording Preset defaultsGeneral Menu procedure How to set or change the Date and time How to set or change the Date Form Algorithm Chart of RecFormat ParametersRecFormat RecFormat parameters ChannelsShows change to How to set or change the RecFormat parametersChange to Kbps Push and release the Jog Wheel when correct Display showsWav 44.1 Stereo Bwf Auto Mark Pre RecordTrack Manual TRAuto Trk Minute trackSeamlsPly Seamless Play SilentSkp Silent Skip Auto Cue Repeat TRK Play ModeNormal Repeat AllDisplay during EDL PlayEDL Play menu turns EDL Play On or Off OffID1Dscrpt, ID2Origin, ID3OrRef Broadcast Wave ID numbers Default Menu Default Display returns to so you can erase another track Renumber tracksTrkERASE AllMkERASE TrkMkERASEDisplay returns to so you can erase another mark To Format a CF card Format CF cardPort How to connect via the I/O portEDL marks and the beginning of a Track Locating EDL MarksSkip marks Loop marksLoopA and LoopB How to Edit EDL marksEDL mark types Point SkipPage Start character End character 0Dh Command formatAscii code @0DS01CR Hand shake flow charts for control commandsHost sends a command that causes a change in PMD570 status Play Status Request Information Code Table of Status Request Status Information codesPCM Care and Maintenance TroubleshootingDigital audio system Specifications1How You Can Get Service Limited WarrantyMarantz is a registered trademark 2004/4