Heat Controller HEV/H manual DXM2 Layout and Connections, P11

Page 31

Heat Controller, Inc.

HEV/H SERIES

Installation, Operation & Maintenance

 

 

 

DXM2 LAYOUT AND CONNECTIONS

Service tool Communicating connection stat connection

Conventional

stat connection

Cabinet

temperature

sensor

(with variable speed pump)

Communications

and HWG

Settings

Accessory relays refer to DXM2 AOM for configuration

P1

 

Y1

 

Y2

 

W

 

O

 

G

 

R

 

C

 

AL1

 

P2

 

AL2

 

R

 

NSB

Alarm

C

Relay

 

ESD

 

OVR

 

H

 

A

 

P3

 

R

 

NO1

 

NC1

 

COM1

F

NO2

act

NC2

ory

COM2

Us

 

e

R

 

COH

COM

C

R

JW1

Acc1 Relay

Acc2 Relay

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P4

 

 

 

 

 

 

 

 

(240Vac)

 

 

 

 

 

Gnd

 

B-

 

A+

24V

(240Vac)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N.O.

 

 

 

N.C.

 

 

 

 

 

 

 

 

 

 

 

 

 

P5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Com

 

 

 

 

 

N.O.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Enable

 

Fan Speed

 

 

 

Test Button

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to Speed up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P8

 

 

Time Delays

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Test

 

P12

12V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

 

 

ECM Motor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gnd

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NC

 

 

Water Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low Temp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Micro

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit Setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

JWT-LT1 jumper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

U1

 

 

 

 

 

 

 

 

 

 

should be clipped

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for low temp

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fault

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LP

 

 

 

 

Status

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(antifreeze)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LT1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LT1

 

 

Factory low

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LT2

 

 

 

Off

On

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

voltage molex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

JW3

 

 

 

 

 

 

LT2

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

connection for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RV

 

 

 

 

 

 

23

 

 

 

 

 

 

 

 

 

 

 

Off

On

 

 

 

 

 

 

 

 

 

 

unit harness

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RV

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

CO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S3 Off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

On

 

 

 

 

 

3

 

 

 

 

 

CO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

4

 

 

 

 

 

 

RV

P7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

6

 

 

CCH

 

 

Relay

 

 

 

Electric heat

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

8

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24Vdc

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Relay

 

 

 

 

 

 

 

 

 

connection

 

 

 

 

 

 

 

 

 

 

5 6

 

 

 

S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EH1

 

 

 

 

 

 

 

 

 

 

 

7 8

A0-1

A0-2

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EH2

 

 

 

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comp

P6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Configurefigure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

modulating valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modulating Valve

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CC

 

 

or variable

P11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P10

 

 

 

 

P9

 

 

(Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

speed pump

AO2 Gnd

 

 

T1

T2

T2

T3

 

T3

 

T4

T4

 

T5

T5

T6

T6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24V to compressor second-stage solenoid for Y2/full

load capacity

Variable speed pump

Entering water temp

Leaving water temp

Leaving air temp

Entering Hot water Temperature

Compressor Discharge temperature

 

 

 

 

Use 4 mounting screws #6 sheet metal screw 1” long

31

Image 31
Contents Residential Packaged Geothermal Heat Pump Table of Contents Unit Nomenclature Configuration Supply AIR OptionsSafety General Information Vertical Upflow Physical DataHE Vertical Upflow Dimensional Data Return Connection Standard Deluxe Filter Frame Vertical Unit Location Vertical InstallationCondensate Piping for Vertical Units Sound Attenuation for Vertical UnitsHorizontal Unit Location Vertical InstallationMounting Horizontal Units Typical Closed Loop Horizontal Unit Installation Horizontal InstallationField Conversion of Air Discharge Field Conversion of AIR DischargeSide to Back Discharge Conversion GROUND-LOOP Heat Pump Applications Water Connection InstallationAntifreeze Low Water Temperature Cutout Setting DXM2 ControlOpen Loop Ground Water Systems GROUND-WATER Heat Pump ApplicationsWater Quality Standards Flow Regulation Water Coil Low Temperature Limit SettingExpansion Tank and Pump Water Control ValveWater Quality Standards Water Quality StandardsHOT Water Generator Typical HWG InstallationInstallation Initial Start-Up Water Tank PreparationHWG Water Piping Water Tank RefillElectrical Line Voltage General Line Voltage WiringElectrical Line Voltage Volt Operation Electrical Power WiringPower Connection HWG WiringLow Water Temperature Cutout Selection Electrical LOW Voltage WiringThermostat Connections Taco Valve Accessory ConnectionsThermostat Thermostat Installation Electrical Thermostat WiringECM Blower Control ECM Blower Performance Data Table Blower Performance DataWiring Diagram Unit Operation DXM2 ControlsP11 DXM2 Layout and ConnectionsOperating Limits Unit Commissioning and Operating ConditionsCommissioning Conditions Unit Starting and Operating Conditions Unit START-UP and Operating Conditions Unit Start-up ProcedureUnit and System Checkout Unit START-UP Procedure Unit START-UP ProcedureHE Coax Water Pressure Drop Unit Operating ConditionsHE Series Typical Unit Operating Pressures and Temperatures Unit Operating Conditions Preventive Maintenance Troubleshooting Start DXM2 Process Flow ChartFault Htg Clg Possible Cause Solution Functional TroubleshootingIFC Fault Code 410A Troubleshooting FormHEV/H Series 97B0016N11

HEV/H specifications

The Heat Controller HEV/H series represents a significant advancement in heating technology, designed to provide efficient and effective climate control for both residential and commercial spaces. This innovative range of heat pumps combines cutting-edge features with user-friendly functionality to offer a reliable solution for modern heating needs.

One of the standout features of the HEV/H series is its advanced inverter technology. This system allows the heat pump to adjust its output based on the specific heating requirements of the environment. By varying the compressor's speed, the HEV/H maintains a consistent temperature while significantly reducing energy consumption. This not only lowers utility bills but also reduces environmental impact, making it a more sustainable option compared to traditional heating methods.

The HEV/H series is equipped with a high-efficiency heat exchanger, which maximizes heat transfer and enhances overall performance. This component ensures that the system can operate effectively even in colder climates, providing reliable heating throughout the winter months. Additionally, the unit’s low noise operation is designed to maintain a peaceful environment, making it suitable for bedrooms, offices, and other noise-sensitive areas.

Another notable characteristic of the HEV/H series is its smart control features. Integrated with Wi-Fi connectivity, users can conveniently manage their heating settings remotely via a smartphone app. This feature allows for customized scheduling and temperature control, ensuring optimal comfort and convenience. Users can also receive real-time notifications on energy consumption and system performance, enhancing user engagement and control.

The HEV/H series also emphasizes durability and longevity. Constructed with high-quality materials, the units are designed to withstand the rigors of daily use while requiring minimal maintenance. The incorporation of advanced filtration systems helps to improve indoor air quality by capturing dust and allergens, which is especially beneficial for individuals with allergies or respiratory issues.

In summary, the Heat Controller HEV/H series exemplifies modern heating technology with its combination of efficiency, control, and user-friendly features. Its inverter technology, high-efficiency heat exchangers, smart connectivity, and durable construction make it an outstanding choice for anyone seeking to enhance their indoor climate while being conscious of energy usage and environmental impact. Whether for a home or business, the HEV/H series is poised to deliver exceptional heating solutions tailored to diverse needs.