Heat Controller HEV/H manual HE Vertical Upflow Dimensional Data

Page 7

Heat Controller, Inc.

 

 

 

 

 

 

 

 

 

 

 

 

HEV/H SERIES

 

Installation, Operation & Maintenance

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HE - VERTICAL UPFLOW DIMENSIONAL DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vertical

 

 

Overall Cabinet

 

 

 

 

 

 

 

 

Upflow

 

A

 

 

 

B

 

 

C

 

 

 

 

 

 

 

 

Model

 

Width

 

 

 

Depth

 

 

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024-030

 

in

22.4

 

 

22.4

 

40.5

 

 

 

 

 

 

 

 

 

cm

56.9

 

 

56.9

 

102.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036-042

 

in

22.4

 

 

26.0

 

46.5

 

 

 

 

 

 

 

 

 

cm

56.9

 

 

66.0

 

118.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

048 -060

 

in

25.4

 

 

29.3

 

50.5

 

 

 

 

 

 

 

 

 

cm

64.5

 

 

74.4

 

128.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water Connections - Standard Units

 

 

 

Vertical

 

1

 

2

 

3

 

4

5

 

 

 

 

Upflow

 

D

 

 

 

E

 

Cond.

 

HWG In

HWG Out

 

Loop

HWG

 

Model

 

Loop

 

Loop

 

 

 

 

 

 

 

 

 

 

Water

 

 

 

 

 

 

 

F

 

 

G

H

 

FPT

 

 

 

 

In

 

 

Out

 

 

 

 

 

FPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024 - 030

 

in

3.8

 

8.8

 

19.5

 

13.4

15.7

 

1

1

 

 

cm

9.6

 

22.3

 

49.5

 

34.0

39.9

 

2.5

2.5

 

 

 

 

 

 

 

 

036 - 042

 

in

3.8

 

8.8

 

22.1

 

15.2

18.5

 

1

1

 

 

cm

9.6

 

22.3

 

56.1

 

38.6

47.0

 

2.5

2.5

 

 

 

 

 

 

 

 

048 - 060

 

in

4.0

 

9.5

 

22.1

 

15.2

18.5

 

1

1

 

 

cm

10.2

 

24.1

 

56.1

 

38.6

47.0

 

2.5

2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Knockouts

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vertical

 

J

 

 

 

K

 

 

L

 

 

 

 

 

 

 

 

 

1/2”

 

 

 

1/2”

 

 

3/4”

 

 

 

 

 

 

 

 

Model

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Low

 

 

 

Ext

 

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

Pump

 

 

Supply

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

024 - 060

 

in

4.6

 

 

 

6.1

 

7.6

 

 

 

 

 

 

 

 

 

cm

11.7

 

 

 

15.5

 

 

19.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

1.While clear access to all removable panels is not required, installer should take care to comply with all building codes and allow adequate clearance for future field service.

2.Front & Side access is preferred for service access. However, all components may be serviced from the front access panel if side

access is not available. 3.Discharge flange is field installed.

4.Condensate is 3/4” socket.

5.Source water and optional HWG connections are 1” swivel.

7

Image 7
Contents Residential Packaged Geothermal Heat Pump Table of Contents Unit Nomenclature Configuration Supply AIR OptionsSafety General Information Vertical Upflow Physical DataHE Vertical Upflow Dimensional Data Return Connection Standard Deluxe Filter Frame Vertical Unit Location Vertical InstallationCondensate Piping for Vertical Units Sound Attenuation for Vertical UnitsHorizontal Unit Location Vertical InstallationMounting Horizontal Units Typical Closed Loop Horizontal Unit Installation Horizontal InstallationField Conversion of Air Discharge Field Conversion of AIR DischargeSide to Back Discharge Conversion GROUND-LOOP Heat Pump Applications Water Connection InstallationAntifreeze Low Water Temperature Cutout Setting DXM2 ControlOpen Loop Ground Water Systems GROUND-WATER Heat Pump ApplicationsWater Quality Standards Flow Regulation Water Coil Low Temperature Limit SettingExpansion Tank and Pump Water Control ValveWater Quality Standards Water Quality StandardsHOT Water Generator Typical HWG InstallationInstallation Initial Start-Up Water Tank PreparationHWG Water Piping Water Tank RefillElectrical Line Voltage General Line Voltage WiringElectrical Line Voltage Volt Operation Electrical Power WiringPower Connection HWG WiringLow Water Temperature Cutout Selection Electrical LOW Voltage WiringThermostat Connections Taco Valve Accessory ConnectionsThermostat Thermostat Installation Electrical Thermostat WiringECM Blower Control ECM Blower Performance Data Table Blower Performance DataWiring Diagram Unit Operation DXM2 ControlsP11 DXM2 Layout and ConnectionsOperating Limits Unit Commissioning and Operating ConditionsCommissioning Conditions Unit Starting and Operating Conditions Unit START-UP and Operating Conditions Unit Start-up ProcedureUnit and System Checkout Unit START-UP Procedure Unit START-UP ProcedureHE Coax Water Pressure Drop Unit Operating ConditionsHE Series Typical Unit Operating Pressures and Temperatures Unit Operating Conditions Preventive Maintenance Troubleshooting Start DXM2 Process Flow ChartFault Htg Clg Possible Cause Solution Functional TroubleshootingIFC Fault Code 410A Troubleshooting FormHEV/H Series 97B0016N11

HEV/H specifications

The Heat Controller HEV/H series represents a significant advancement in heating technology, designed to provide efficient and effective climate control for both residential and commercial spaces. This innovative range of heat pumps combines cutting-edge features with user-friendly functionality to offer a reliable solution for modern heating needs.

One of the standout features of the HEV/H series is its advanced inverter technology. This system allows the heat pump to adjust its output based on the specific heating requirements of the environment. By varying the compressor's speed, the HEV/H maintains a consistent temperature while significantly reducing energy consumption. This not only lowers utility bills but also reduces environmental impact, making it a more sustainable option compared to traditional heating methods.

The HEV/H series is equipped with a high-efficiency heat exchanger, which maximizes heat transfer and enhances overall performance. This component ensures that the system can operate effectively even in colder climates, providing reliable heating throughout the winter months. Additionally, the unit’s low noise operation is designed to maintain a peaceful environment, making it suitable for bedrooms, offices, and other noise-sensitive areas.

Another notable characteristic of the HEV/H series is its smart control features. Integrated with Wi-Fi connectivity, users can conveniently manage their heating settings remotely via a smartphone app. This feature allows for customized scheduling and temperature control, ensuring optimal comfort and convenience. Users can also receive real-time notifications on energy consumption and system performance, enhancing user engagement and control.

The HEV/H series also emphasizes durability and longevity. Constructed with high-quality materials, the units are designed to withstand the rigors of daily use while requiring minimal maintenance. The incorporation of advanced filtration systems helps to improve indoor air quality by capturing dust and allergens, which is especially beneficial for individuals with allergies or respiratory issues.

In summary, the Heat Controller HEV/H series exemplifies modern heating technology with its combination of efficiency, control, and user-friendly features. Its inverter technology, high-efficiency heat exchangers, smart connectivity, and durable construction make it an outstanding choice for anyone seeking to enhance their indoor climate while being conscious of energy usage and environmental impact. Whether for a home or business, the HEV/H series is poised to deliver exceptional heating solutions tailored to diverse needs.