UNIT OPERATING CONDITIONS

Table 10: HE Coax Water Pressure Drop

Model

GPM

 

Pressure Drop (psi)

 

30°F

50°F

70°F

90°F

 

 

 

2.5

0.8

0.3

0.2

0.2

024

3.0

1.2

0.6

0.5

0.5

3.8

1.8

1.1

0.9

0.8

Rev B

4.5

2.7

1.6

1.2

1.2

 

 

6.0

3.9

2.8

2.2

2.0

 

3.0

1.7

0.9

0.8

0.8

030

3.8

2.3

1.2

1.1

1.1

4.5

2.7

1.6

1.4

1.4

 

6.0

3.8

2.4

2.2

2.1

 

7.5

5.1

3.5

3.1

2.9

 

4.0

0.6

0.1

0.1

0.1

036

6.0

1.8

1.0

0.7

0.7

6.8

2.3

1.5

1.1

1.1

Rev B

8.0

3.2

2.2

1.8

1.7

 

 

9.0

4.0

2.9

2.4

2.3

 

3.8

1.7

1.0

0.9

0.9

042

5.3

2.7

1.8

1.6

1.5

7.5

4.5

3.1

2.8

2.6

 

7.9

4.8

3.4

3.1

2.9

 

10.5

7.4

5.4

4.9

4.7

 

4.5

1.4

1.1

0.9

0.8

048

6.0

2.0

1.7

1.4

1.3

6.8

2.5

2.1

1.8

1.7

 

9.0

4.0

3.4

3.0

2.7

 

12.0

6.5

5.5

4.9

4.5

 

6.0

4.0

2.6

2.4

2.4

060

7.5

5.4

3.8

3.3

3.3

9.0

6.8

4.9

4.4

4.3

 

12.0

10.6

7.9

7.0

6.7

 

15.0

16.2

12.8

11.1

10.1

Table 12: Antifreeze Correction

Table 11: Water Temperature Change Through Heat Exchanger

 

 

 

 

 

9 - 12

4

- 8

 

 

 

 

 

20 - 26

10

- 17

 

 

 

 

 

 

 

Cooling

 

Heating

WPD

 

Antifreeze

 

 

 

 

 

 

 

 

 

 

 

Antifreeze Type

 

EWT 90°F

 

EWT 30°F

Corr. Fct.

%

 

 

 

 

 

 

 

 

EWT 30°F

 

 

Total Cap

Sens Cap

Power

Htg Cap

Power

 

 

 

 

 

 

 

 

 

 

 

Water

0

1.000

1.000

1.000

1.000

1.000

1.000

 

 

 

 

 

 

 

 

 

5

0.995

0.995

1.003

0.989

0.997

1.070

Propylene Glycol

 

 

 

 

 

 

 

15

0.986

0.986

1.009

0.968

0.990

1.210

 

25

0.978

0.978

1.014

0.947

0.983

1.360

 

 

 

 

 

 

 

 

 

5

0.997

0.997

1.002

0.989

0.997

1.070

Methanol

 

 

 

 

 

 

 

15

0.990

0.990

1.007

0.968

0.990

1.160

 

25

0.982

0.982

1.012

0.949

0.984

1.220

 

 

 

 

 

 

 

 

 

5

0.998

0.998

1.002

0.981

0.994

1.140

Ethanol

 

 

 

 

 

 

 

15

0.994

0.994

1.005

0.944

0.983

1.300

 

25

0.986

0.986

1.009

0.917

0.974

1.360

 

 

 

 

 

 

 

 

 

5

0.998

0.998

1.002

0.993

0.998

1.040

Ethylene Glycol

 

 

 

 

 

 

 

15

0.994

0.994

1.004

0.980

0.994

1.120

 

25

0.988

0.988

1.008

0.966

0.990

1.200

36

Image 36
Contents Residential Packaged Geothermal Heat Pump Table of Contents Configuration Supply AIR Options Unit NomenclatureSafety General Information Physical Data Vertical UpflowHE Vertical Upflow Dimensional Data Return Connection Standard Deluxe Filter Frame Vertical Installation Vertical Unit LocationSound Attenuation for Vertical Units Condensate Piping for Vertical UnitsVertical Installation Horizontal Unit LocationMounting Horizontal Units Horizontal Installation Typical Closed Loop Horizontal Unit InstallationField Conversion of AIR Discharge Field Conversion of Air DischargeSide to Back Discharge Conversion Water Connection Installation GROUND-LOOP Heat Pump ApplicationsLow Water Temperature Cutout Setting DXM2 Control AntifreezeGROUND-WATER Heat Pump Applications Open Loop Ground Water SystemsWater Quality Standards Water Coil Low Temperature Limit Setting Expansion Tank and PumpWater Control Valve Flow RegulationWater Quality Standards Water Quality StandardsTypical HWG Installation HOT Water GeneratorInstallation Water Tank Preparation HWG Water PipingWater Tank Refill Initial Start-UpGeneral Line Voltage Wiring Electrical Line VoltageElectrical Line Voltage Electrical Power Wiring Power ConnectionHWG Wiring Volt OperationElectrical LOW Voltage Wiring Low Water Temperature Cutout SelectionThermostat Connections Accessory Connections Taco ValveThermostat Electrical Thermostat Wiring Thermostat InstallationECM Blower Control Blower Performance Data ECM Blower Performance Data TableWiring Diagram DXM2 Controls Unit OperationDXM2 Layout and Connections P11Unit Commissioning and Operating Conditions Operating LimitsCommissioning Conditions Unit Starting and Operating Conditions Unit Start-up Procedure Unit START-UP and Operating ConditionsUnit and System Checkout Unit START-UP Procedure Unit START-UP ProcedureUnit Operating Conditions HE Coax Water Pressure DropHE Series Typical Unit Operating Pressures and Temperatures Unit Operating Conditions Preventive Maintenance Troubleshooting DXM2 Process Flow Chart StartFunctional Troubleshooting Fault Htg Clg Possible Cause SolutionIFC Fault Code Troubleshooting Form 410AHEV/H Series 97B0016N11

HEV/H specifications

The Heat Controller HEV/H series represents a significant advancement in heating technology, designed to provide efficient and effective climate control for both residential and commercial spaces. This innovative range of heat pumps combines cutting-edge features with user-friendly functionality to offer a reliable solution for modern heating needs.

One of the standout features of the HEV/H series is its advanced inverter technology. This system allows the heat pump to adjust its output based on the specific heating requirements of the environment. By varying the compressor's speed, the HEV/H maintains a consistent temperature while significantly reducing energy consumption. This not only lowers utility bills but also reduces environmental impact, making it a more sustainable option compared to traditional heating methods.

The HEV/H series is equipped with a high-efficiency heat exchanger, which maximizes heat transfer and enhances overall performance. This component ensures that the system can operate effectively even in colder climates, providing reliable heating throughout the winter months. Additionally, the unit’s low noise operation is designed to maintain a peaceful environment, making it suitable for bedrooms, offices, and other noise-sensitive areas.

Another notable characteristic of the HEV/H series is its smart control features. Integrated with Wi-Fi connectivity, users can conveniently manage their heating settings remotely via a smartphone app. This feature allows for customized scheduling and temperature control, ensuring optimal comfort and convenience. Users can also receive real-time notifications on energy consumption and system performance, enhancing user engagement and control.

The HEV/H series also emphasizes durability and longevity. Constructed with high-quality materials, the units are designed to withstand the rigors of daily use while requiring minimal maintenance. The incorporation of advanced filtration systems helps to improve indoor air quality by capturing dust and allergens, which is especially beneficial for individuals with allergies or respiratory issues.

In summary, the Heat Controller HEV/H series exemplifies modern heating technology with its combination of efficiency, control, and user-friendly features. Its inverter technology, high-efficiency heat exchangers, smart connectivity, and durable construction make it an outstanding choice for anyone seeking to enhance their indoor climate while being conscious of energy usage and environmental impact. Whether for a home or business, the HEV/H series is poised to deliver exceptional heating solutions tailored to diverse needs.