Heat Controller VMH 12 Wall-mounted type, Selecting installation place, Indoor unit, Outdoor unit

Page 4

VMH InverterFlex Mini-Split

INSTALLATION MANUAL

Heat Controller, Inc.

1. Wall-mounted type

Selecting installation place

Read completely, then follow step by step.

Indoor unit

Do not expose the indoor unit to heat or steam.

Select a place where there are no obstacles in front or around the unit.

Make sure that condensation drainage can be conveniently routed away.

Do not install near a doorway.

Ensure that the space on the left and right of the unit is more than 5in.(12cm).

Use a stud finder to locate studs to prevent unnecessary damage to the wall.

The indoor unit should be installed on the wall at a height of 6.5ft.(2m) or more from the floor.

The indoor unit should be installed allowing a minimum clearance of 6in.(15cm) from the ceiling.

Any variations in pipe length may require adjustment to refrigerant charge.

Do not expose unit to direct sunlight. The sun will fade the plastic cabinet and affect its appearance.

Outdoor unit

If an awning is built over the outdoor unit to prevent direct sunlight or rain exposure, make sure that heat radiation from the condenser is not restricted.

Ensure that the clearance around the back of the unit is more than 12in.(30cm) and left side is more than 12in.(30cm). The front of the unit should have more than 79in.(200cm) of clearance and the connection side (right side) should have more than 24in.(60cm)of clearance.

Do not place animals and plants in the path of the air inlet or outlet.

Take the air conditioner weight into account and select a place where noise and vibration will not be an issue.

Select a place so that the warm air and noise from the air conditioner do not disturb neighbors.

Rooftop installation

If the outdoor unit is installed on a roof structure, be sure to level the unit.

Ensure the roof structure and anchoring method are adequate for the unit location.

Consult local codes regarding rooftop mounting.

If the outdoor unit is installed on roof structures or external walls, this may result in excessive noise and vibra- tion, and may also be considered a non-serviceable installation.

3

Image 4
Contents Installation Manual Table of Contents This symbol denotes item that is Prohibited from doing Selecting installation place Rooftop installationWall-mounted type Indoor unitAccessories Single-Dual Zone Single-Tri Zone Single-Quad Zone Indoor unit installation wall-mounted type Installation PlateConnective Pipe and Drainage Installation Drill a hole in the wallIndoor unit Indoor unit installation Outdoor installation precaution Outdoor Unit InstallationAnchoring outdoor unit Refrigerant Pipe Connection Tightening Connection Refrigerant Pipe ConnectionFlaring work Electrical Work Connect the cable to the outdoor unit Air Purging Air purging with vacuum pumpWhen Using the Vacuum Pump Leak Check Safety and leakage check Electrical safety check Testing the System Wellorks. well09/2010