Flaring Work and Connection of Piping

Check

1.Compare the flared work with the figure on the right.

2.If a flared section is defective, cut it off and repeat the flaring process again.

Smooth all round

 

 

Inside is shiny without scratches

 

= Improper flaring =

Inclined

Surface

Cracked Uneven

Even length

damaged

thickness

 

 

all round

 

 

Connecting the Piping

Indoor

1. Prepare the indoor unit's piping and drain hose for installation through the wall.

2. Remove the plastic tubing retainer(see the illustration on the right) and pull the tubing and drain hose away from chassis.

For right rear piping

1.Route the indoor tubing and the drain hose in the direction of rear right.

2.Insert the connecting cable into the indoor unit from the outdoor unit through the piping hole.

Do not connect the cable to the indoor unit.

Make a small loop with the cable for easy connection later.

3.Tape the tubing, drain hose, and the connecting on cable. Be sure that the drain hose is located on the lowest side of the bundle. Locating on the upper side can cause the condensation to overflow in the drain pan inside the indoor unit.

If the drain hose is routed inside the room, insulate the hose with an insulation material* so that dripping from "sweating"(condensation) will not damage furniture or floors.

*Foamed polyethylene or equivalent is recommended.

Drain hose

Tape

Connecting

pipe

Drain hose

Connecting cable

12Wall Mounted Multi-Zone Split System Air Conditioner

Image 12
Contents Heat CONTROLLER, INC Table of Contents Installation Parts Provided 18/24K BTU/h36K BTU/h Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk of fire or electric shock For electrical work, contactDo not modify or extend the power cable Do not let the air conditionerRun for a long time when Humidity is very high and aInstall the drain hose to Keep level even when Installing the productAway properly Bad connection may cause Water leakage LeakageInstallation of Indoor, Outdoor Unit Rooftop InstallationsSelect the best location Indoor unitSeaside Applications and Installation Selecting the locationOutdoor UnitPiping length and elevation Multi-Zone Piping Recommendations18/24K BTU/h 36K BTU/h Mounting Installation Plate Drilling the hole in the wallFlaring work Cut the pipesBurrs removal Putting flare nuts onConnecting the Piping CheckIndoor Foamed polyethylene or equivalent is recommendedIndoor unit installation Wrap the insulation material around all connectionsFor left rear piping Wrap the insulation material around the connecting portion Indoor unit installationBest Practice Worst PracticeOutdoor Outside diameter TorqueConnect the cable to the Indoor unit RecommendationConnect the cable to the Outdoor unit Outdoor unitMethods of connecting the cable How to connect wiring to the terminalsFor strand wiring High voltage Strand wireModel Checking the drainage To check the drainageDrain piping Pour a glass of water into the evaporatorInsulating the Pipe and Special Piping Applications Air Purging and Evacuation Leak CheckingPreparation Leakage testRepeat evacuation procedure for each indoor unit EvacuationFinishing the job Charging Max totalCapacity Prepare remote control Test RunningEvaluation of the performance 03-18-08 No. MFL39059502
Related manuals
Manual 27 pages 12.68 Kb

MMH18DA-1, MMH24DA-1, MMC24DA-1, MMC36TA-1, MMH36TA-1 specifications

The Heat Controller series, including models MMC18DA-1, MMH36TA-1, MMC36TA-1, MMC24DA-1, and MMH24DA-1, represents a robust line of heating and cooling solutions designed for efficiency, reliability, and user comfort. These models are popular choices for both residential and light commercial applications, offering a blend of advanced technology and user-friendly features.

One of the standout features of these units is their energy efficiency. Each model is engineered to minimize energy consumption while maximizing heating and cooling capacities. The incorporation of SEER and HSPF ratings allows users to evaluate the energy performance of these units, ensuring they make an environmentally responsible choice that helps reduce energy costs.

Technologically, the Heat Controller units utilize inverter technology, which enables the system to adjust the compressor speed based on the required heating or cooling output. This leads to a more consistent indoor temperature and reduces wear and tear on the system, promoting longevity. Additionally, the quiet operation of these units makes them ideal for residential settings where noise can be a concern.

The MMC and MMH models also come equipped with advanced climatic control capabilities. Many units feature programmable thermostats that allow users to set schedules, thereby optimizing energy usage during peak and off-peak hours. These smart controls can be easily adjusted via user-friendly interfaces, ensuring that comfort is just a click away.

Durability and reliability are other hallmarks of the Heat Controller series. The outdoor units are designed to withstand harsh weather conditions, featuring a robust build that includes protective coatings to guard against corrosion and other environmental challenges. Moreover, the compressors used in these models are crafted for maximum efficiency, ensuring that they deliver reliable performance year after year.

Installation flexibility is another key benefit. These heating and cooling systems can be installed in various configurations, making them suitable for a range of settings, from tight urban spaces to larger commercial environments.

With a commitment to quality and customer satisfaction, Heat Controller models MMC18DA-1, MMH36TA-1, MMC36TA-1, MMC24DA-1, and MMH24DA-1 cater to diverse heating and cooling needs, harnessing technology and design to enhance user comfort and efficiency in any environment.