Heat Controller MMC36TA-1, MMC18DA-1 Wrap the insulation material around the connecting portion

Page 15

Flaring Work and Connection of Piping

Wrap the insulation material around the connecting portion.

1.Overlap the connection pipe insulation and the indoor unit pipe heat insulation material. Bind them together with vinyl tape so that there is no gap.

2.Wrap the area which accommodates the rear piping housing section with vinyl tape.

Plastic bands

Insulation material

 

Connection

Indoor

unit piping

pipe

 

Vinyl tape

Wrap with vinyl tape

(wide)

 

 

Pipe

 

Vinyl tape(narrow)

Connecting cable

 

3.Bundle the piping and drain hose together by wrapping them with vinyl tape over the range within which they fit into the rear piping housing section.

Reroute the piping and the drain hose across the back of the chassis.

Drain hose

Pipe

Vinyl tape(narrow)

Wrap with vinyl tape(wide)

Indoor unit installation

1.Remove the spacer.

2.Ensure that the hooks are properly seated on the installation plate by moving it left and right.

3.Press the lower left and right sides of the unit against the installation plate until the hooks engage into their slots(clicking sound).

Piping for passage through piping hole

Connecting cable

Drain hose

Installation Manual 15

Image 15
Contents Heat CONTROLLER, INC Table of Contents Installation Parts Provided 18/24K BTU/h36K BTU/h For electrical work, contact Safety PrecautionsBe sure not to do Be sure to follow the instruction There is risk of fire or electric shockHumidity is very high and a Do not modify or extend the power cableDo not let the air conditioner Run for a long time whenWater leakage Leakage Install the drain hose to Keep level even whenInstalling the product Away properly Bad connection may causeIndoor unit Installation of Indoor, Outdoor UnitRooftop Installations Select the best locationSelecting the locationOutdoor Unit Seaside Applications and InstallationPiping length and elevation Multi-Zone Piping Recommendations18/24K BTU/h 36K BTU/h Drilling the hole in the wall Mounting Installation PlatePutting flare nuts on Flaring workCut the pipes Burrs removalFoamed polyethylene or equivalent is recommended Connecting the PipingCheck IndoorWrap the insulation material around all connections Indoor unit installationFor left rear piping Indoor unit installation Wrap the insulation material around the connecting portionWorst Practice Best PracticeOutside diameter Torque OutdoorRecommendation Connect the cable to the Indoor unitOutdoor unit Connect the cable to the Outdoor unitHigh voltage Strand wire Methods of connecting the cableHow to connect wiring to the terminals For strand wiringModel Pour a glass of water into the evaporator Checking the drainageTo check the drainage Drain pipingInsulating the Pipe and Special Piping Applications Leakage test Air Purging and EvacuationLeak Checking PreparationRepeat evacuation procedure for each indoor unit EvacuationFinishing the job Charging Max totalCapacity Prepare remote control Test RunningEvaluation of the performance 03-18-08 No. MFL39059502
Related manuals
Manual 27 pages 12.68 Kb

MMH18DA-1, MMH24DA-1, MMC24DA-1, MMC36TA-1, MMH36TA-1 specifications

The Heat Controller series, including models MMC18DA-1, MMH36TA-1, MMC36TA-1, MMC24DA-1, and MMH24DA-1, represents a robust line of heating and cooling solutions designed for efficiency, reliability, and user comfort. These models are popular choices for both residential and light commercial applications, offering a blend of advanced technology and user-friendly features.

One of the standout features of these units is their energy efficiency. Each model is engineered to minimize energy consumption while maximizing heating and cooling capacities. The incorporation of SEER and HSPF ratings allows users to evaluate the energy performance of these units, ensuring they make an environmentally responsible choice that helps reduce energy costs.

Technologically, the Heat Controller units utilize inverter technology, which enables the system to adjust the compressor speed based on the required heating or cooling output. This leads to a more consistent indoor temperature and reduces wear and tear on the system, promoting longevity. Additionally, the quiet operation of these units makes them ideal for residential settings where noise can be a concern.

The MMC and MMH models also come equipped with advanced climatic control capabilities. Many units feature programmable thermostats that allow users to set schedules, thereby optimizing energy usage during peak and off-peak hours. These smart controls can be easily adjusted via user-friendly interfaces, ensuring that comfort is just a click away.

Durability and reliability are other hallmarks of the Heat Controller series. The outdoor units are designed to withstand harsh weather conditions, featuring a robust build that includes protective coatings to guard against corrosion and other environmental challenges. Moreover, the compressors used in these models are crafted for maximum efficiency, ensuring that they deliver reliable performance year after year.

Installation flexibility is another key benefit. These heating and cooling systems can be installed in various configurations, making them suitable for a range of settings, from tight urban spaces to larger commercial environments.

With a commitment to quality and customer satisfaction, Heat Controller models MMC18DA-1, MMH36TA-1, MMC36TA-1, MMC24DA-1, and MMH24DA-1 cater to diverse heating and cooling needs, harnessing technology and design to enhance user comfort and efficiency in any environment.