Heat Controller MMH36TA-1, MMC18DA-1, MMC24DA-1, MMC36TA-1, MMH24DA-1, MMH18DA-1 For left rear piping

Page 14

Flaring Work and Connection of Piping

For left rear piping

1.Route the indoor tubing and the drain hose to the required piping hole position.

2.Insert the piping, drain hose, and the connecting cable into the piping hole.

3.Insert the connecting cable into the indoor unit.

Don't connect the cable to the indoor unit.

Make a small loop with the cable for easy connection later.

4.Tape the drain hose and the connecting cables.

Connecting

cable

Drain pipe

5.Indoor unit installation

Hang the indoor unit from the hooks at the top of the installation plate.

Insert the spacer between the indoor unit and the installation plate and separate the bottom of the indoor unit from the wall.

Connecting the piping to the indoor unit and the drain hose to drain pipe.

1.Align the center of the pipes and sufficiently tighten the flare nut by hand.

2.Tighten the flare nut with a wrench.

Outside diameter

Torque

 

 

 

mm

inch

kgf.m (lbf-ft)

Ø6.35

1/4

1.8 ~ 2.5 (13)

Ø9.52

3/8

3.4 ~ 4.2 (20)

3.Next, extend the indoor unit's drain hose. Then attach the drain pipe.

Indoor unit

Spacer

Installation plate

8cm (3.15 inch)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor unit tubing

Flare nut Pipes

 

 

 

 

 

 

 

 

 

 

Open-end wrench (fixed)

Flare nut

Wrench

Connection pipe

Indoor unit tubing

Drain hose

Indoor unit drain hose

Adhesive Vinyl tape (narrow)

14Wall Mounted Multi-Zone Split System Air Conditioner

Image 14
Contents Heat CONTROLLER, INC Table of Contents 36K BTU/h Installation Parts Provided18/24K BTU/h There is risk of fire or electric shock Safety PrecautionsBe sure not to do Be sure to follow the instruction For electrical work, contactRun for a long time when Do not modify or extend the power cableDo not let the air conditioner Humidity is very high and aAway properly Bad connection may cause Install the drain hose to Keep level even whenInstalling the product Water leakage LeakageSelect the best location Installation of Indoor, Outdoor UnitRooftop Installations Indoor unitSeaside Applications and Installation Selecting the locationOutdoor Unit18/24K BTU/h 36K BTU/h Piping length and elevationMulti-Zone Piping Recommendations Mounting Installation Plate Drilling the hole in the wallBurrs removal Flaring workCut the pipes Putting flare nuts onIndoor Connecting the PipingCheck Foamed polyethylene or equivalent is recommendedIndoor unit installation Wrap the insulation material around all connectionsFor left rear piping Wrap the insulation material around the connecting portion Indoor unit installationBest Practice Worst PracticeOutdoor Outside diameter TorqueConnect the cable to the Indoor unit RecommendationConnect the cable to the Outdoor unit Outdoor unitFor strand wiring Methods of connecting the cableHow to connect wiring to the terminals High voltage Strand wireModel Drain piping Checking the drainageTo check the drainage Pour a glass of water into the evaporatorInsulating the Pipe and Special Piping Applications Preparation Air Purging and EvacuationLeak Checking Leakage testFinishing the job Repeat evacuation procedure for each indoor unitEvacuation Capacity ChargingMax total Evaluation of the performance Prepare remote controlTest Running 03-18-08 No. MFL39059502
Related manuals
Manual 27 pages 12.68 Kb

MMH18DA-1, MMH24DA-1, MMC24DA-1, MMC36TA-1, MMH36TA-1 specifications

The Heat Controller series, including models MMC18DA-1, MMH36TA-1, MMC36TA-1, MMC24DA-1, and MMH24DA-1, represents a robust line of heating and cooling solutions designed for efficiency, reliability, and user comfort. These models are popular choices for both residential and light commercial applications, offering a blend of advanced technology and user-friendly features.

One of the standout features of these units is their energy efficiency. Each model is engineered to minimize energy consumption while maximizing heating and cooling capacities. The incorporation of SEER and HSPF ratings allows users to evaluate the energy performance of these units, ensuring they make an environmentally responsible choice that helps reduce energy costs.

Technologically, the Heat Controller units utilize inverter technology, which enables the system to adjust the compressor speed based on the required heating or cooling output. This leads to a more consistent indoor temperature and reduces wear and tear on the system, promoting longevity. Additionally, the quiet operation of these units makes them ideal for residential settings where noise can be a concern.

The MMC and MMH models also come equipped with advanced climatic control capabilities. Many units feature programmable thermostats that allow users to set schedules, thereby optimizing energy usage during peak and off-peak hours. These smart controls can be easily adjusted via user-friendly interfaces, ensuring that comfort is just a click away.

Durability and reliability are other hallmarks of the Heat Controller series. The outdoor units are designed to withstand harsh weather conditions, featuring a robust build that includes protective coatings to guard against corrosion and other environmental challenges. Moreover, the compressors used in these models are crafted for maximum efficiency, ensuring that they deliver reliable performance year after year.

Installation flexibility is another key benefit. These heating and cooling systems can be installed in various configurations, making them suitable for a range of settings, from tight urban spaces to larger commercial environments.

With a commitment to quality and customer satisfaction, Heat Controller models MMC18DA-1, MMH36TA-1, MMC36TA-1, MMC24DA-1, and MMH24DA-1 cater to diverse heating and cooling needs, harnessing technology and design to enhance user comfort and efficiency in any environment.