Heat Controller MMC36TA-1 manual Piping length and elevation, Multi-Zone Piping Recommendations

Page 9

Installation of Indoor, Outdoor Unit

Piping lengthand elevation

Multi-Zone Piping Recommendations:

 

Max total length

Max length of

Min length of

Max Elevation

Max elevation

 

between each

Capacity

of all pipes

each pipe

each pipe

 

between indoor

 

indoor unit and

 

(A+B/A+B+C)

 

(A/B/C)

(A/B/C)

 

units (h2)

 

 

 

outdoor unit (h1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18K BTU/h

30 m (100 ft)

15 m (50 ft)

3 m (10 ft)

 

7.5 m (25 ft)

7.5 m (25 ft)

 

 

 

 

 

 

 

 

 

 

 

24K BTU/h

30 m (100 ft)

15 m (50 ft)

3 m (10 ft)

 

7.5 m (25 ft)

7.5 m (25 ft)

 

 

 

 

 

 

 

 

 

 

 

36K BTU/h

45 m (150 ft)

15 m (50 ft)

3 m (10 ft)

 

7.5 m (25 ft)

7.5 m (25 ft)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe Size

 

 

 

Indoor Capacity

 

 

 

 

 

 

 

 

 

 

Gas (Flare)

 

Liquid (Flare)

Standard Length

 

Additional

 

 

 

 

Refrigerant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9K BTU/h

 

9.52 mm (3/8")

 

6.35 mm (1/4")

 

7.5 m (25 ft)

20 g/m (0.22 oz/ft)

 

 

 

 

 

 

 

 

12K BTU/h

 

9.52 mm (3/8")

 

6.35 mm (1/4")

 

7.5 m (25 ft)

20 g/m (0.22 oz/ft)

 

 

 

 

 

 

 

 

 

 

 

 

18/24K BTU/h

A

B

h1

h1

36K BTU/h

A

h2

h1

B

C

h2

h2

h1

h1

B

CAUTION: Capacity is based on standard length and maximum allowance length based on reliability.

Installation Manual 9

Image 9
Contents Heat CONTROLLER, INC Table of Contents Installation Parts Provided 18/24K BTU/h36K BTU/h Be sure not to do Be sure to follow the instruction Safety PrecautionsThere is risk of fire or electric shock For electrical work, contactDo not let the air conditioner Do not modify or extend the power cableRun for a long time when Humidity is very high and aInstalling the product Install the drain hose to Keep level even whenAway properly Bad connection may cause Water leakage LeakageRooftop Installations Installation of Indoor, Outdoor UnitSelect the best location Indoor unitSelecting the locationOutdoor Unit Seaside Applications and InstallationPiping length and elevation Multi-Zone Piping Recommendations18/24K BTU/h 36K BTU/h Drilling the hole in the wall Mounting Installation PlateCut the pipes Flaring workBurrs removal Putting flare nuts onCheck Connecting the PipingIndoor Foamed polyethylene or equivalent is recommendedWrap the insulation material around all connections Indoor unit installationFor left rear piping Indoor unit installation Wrap the insulation material around the connecting portionWorst Practice Best PracticeOutside diameter Torque OutdoorRecommendation Connect the cable to the Indoor unitOutdoor unit Connect the cable to the Outdoor unitHow to connect wiring to the terminals Methods of connecting the cableFor strand wiring High voltage Strand wireModel To check the drainage Checking the drainageDrain piping Pour a glass of water into the evaporatorInsulating the Pipe and Special Piping Applications Leak Checking Air Purging and EvacuationPreparation Leakage testRepeat evacuation procedure for each indoor unit EvacuationFinishing the job Charging Max totalCapacity Prepare remote control Test RunningEvaluation of the performance 03-18-08 No. MFL39059502
Related manuals
Manual 27 pages 12.68 Kb

MMH18DA-1, MMH24DA-1, MMC24DA-1, MMC36TA-1, MMH36TA-1 specifications

The Heat Controller series, including models MMC18DA-1, MMH36TA-1, MMC36TA-1, MMC24DA-1, and MMH24DA-1, represents a robust line of heating and cooling solutions designed for efficiency, reliability, and user comfort. These models are popular choices for both residential and light commercial applications, offering a blend of advanced technology and user-friendly features.

One of the standout features of these units is their energy efficiency. Each model is engineered to minimize energy consumption while maximizing heating and cooling capacities. The incorporation of SEER and HSPF ratings allows users to evaluate the energy performance of these units, ensuring they make an environmentally responsible choice that helps reduce energy costs.

Technologically, the Heat Controller units utilize inverter technology, which enables the system to adjust the compressor speed based on the required heating or cooling output. This leads to a more consistent indoor temperature and reduces wear and tear on the system, promoting longevity. Additionally, the quiet operation of these units makes them ideal for residential settings where noise can be a concern.

The MMC and MMH models also come equipped with advanced climatic control capabilities. Many units feature programmable thermostats that allow users to set schedules, thereby optimizing energy usage during peak and off-peak hours. These smart controls can be easily adjusted via user-friendly interfaces, ensuring that comfort is just a click away.

Durability and reliability are other hallmarks of the Heat Controller series. The outdoor units are designed to withstand harsh weather conditions, featuring a robust build that includes protective coatings to guard against corrosion and other environmental challenges. Moreover, the compressors used in these models are crafted for maximum efficiency, ensuring that they deliver reliable performance year after year.

Installation flexibility is another key benefit. These heating and cooling systems can be installed in various configurations, making them suitable for a range of settings, from tight urban spaces to larger commercial environments.

With a commitment to quality and customer satisfaction, Heat Controller models MMC18DA-1, MMH36TA-1, MMC36TA-1, MMC24DA-1, and MMH24DA-1 cater to diverse heating and cooling needs, harnessing technology and design to enhance user comfort and efficiency in any environment.