Heat Controller REG-71A, REG-123A Operation, Features, Control Locations Function of Controls

Page 14

Operation

Operation

Features

Designed for COOLING and HEATING.

Powerful and whispering cooling.

Slide-in and slide-out chassis for the simple instal- lation and service.

Side air-intake, side cooled-air discharge.

Built-in adjustable THERMOSTAT

Washable one-touch filter

Compact size

Reliable and efficient rotary compressor

ControlLocationsFunctionofControls

• VENTILATION

The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions.

When a fresh air is necessary in the room, set the ven- tilation lever to the OPEN position.

The damper is opened and room air is exhausted.

1. POWER BUTTON

To turn the air conditioner ON, push the button. To turn the air conditioner OFF, push the button again.

This button takes priority over any other buttons.

2. OPERATION MODE SELECTION BUTTON

Everytime you push this button, it will toggle COOL, FAN and HEAT.

3. ON/OFF TIMER BUTTON

Everytime you push this button, timer is set as follows.(1Hour 2Hours 3Hours 4Hours 5Hours 6Hours 7Hours 8Hours 9Hours 10Hours 11Hours 12Hours Cancel)

4. FAN SPEED SELECTOR

Everytime you push this button, it is set as follows.

(Hi[

] Low[

] Hi[

]....)

5. ROOM TEMPERATURE SETTING BUTTON

This button can automatically control the temperature of the room. The temperature can be set within a range of 60°F to 86°F by 1°F.

6. ENERGY SAVER

The fan stops when the compressor stops cooling. Approximately every 3 munutes the fan will turn on and check the room air to determine if cooling is needed.

7.REMOCON SIGNAL RECEIVER

8.AUTO SWING

CLOSE VENT OPEN

REG-123A

2

3

6

4

5

REG-71A

 

4

7

 

Heat

3

6

2

5

1

REMOTE CONTROLLER

REG-123AREG-71A

This button can automatically control the air flow direction.

CAUTION: A slight heat odor may come from the unit when first

switching to HEAT after the cooling season is over. This odor, caused by fine dust particles on the heater, will disappear quickly.

 

Power

 

Power

 

1

 

1

Temp

Temp

5

 

5

 

Fan Speed

Fan Speed

 

4

 

4

Timer

Mode

Timer

Mode

3

2

3

2

Energy

Auto

Energy

 

Saver

Swing

Saver

 

7

8

7

 

14Room Air Conditioner

Image 14
Contents +$7&21752//5,1& Table of Contents Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk or fire or electric shock Outside Dimensions DimensionsSymbols Used in this Manual Product Specifications ItemsSelect the Best Location InstallationInstallation Check OptionalHow to InstallModels without Installation Kit When Using Installation Kits How to InstallModels with Installaion KitWhen Using Gasket REG-123A REG-71A Preparation of Chassis Cabinet InstallationSuggested Tool Requirements Indoor Slide the unit into the cabinet.See Fig Control Locations Function of Controls FeaturesOperation Front Grille DisassemblyMechanical Parts CabinetFAN Air Handling PartsAir Guide and Turbo Fan Overload Protector Electrical PartsShroud CompressorThermistor Power CordCapacitor Evaporator Refrigerating CycleMotor Capillary Tube Pulling Vacuum Schematic Diagram Wiring DiagramTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide +$7&21752//5,1&

REG-123A, REG-71A specifications

The Heat Controller REG-71A and REG-123A are innovative climate control units designed to provide efficient heating and cooling solutions for residential and commercial spaces. These models are characterized by advanced technologies that enhance energy efficiency, user comfort, and operational convenience.

One of the standout features of the REG-71A and REG-123A is their inverter technology. This technology allows the units to adjust their cooling and heating output based on the real-time demand, resulting in reduced energy consumption. By maintaining the desired temperature with minimal fluctuations, these models not only save on energy bills but also create a more comfortable indoor environment.

Another critical characteristic of these heat controllers is their Eco-friendly refrigerant, R32. This refrigerant has a lower Global Warming Potential (GWP) compared to traditional refrigerants, making the REG-71A and REG-123A environmentally responsible choices. Users can enjoy climate control without compromising on sustainability.

The units are designed with a user-friendly interface, featuring an intuitive remote control that enables users to adjust temperature settings, fan speeds, and operating modes easily. Additionally, both models include a programmable timer that allows for automatic operation based on individual schedules, ensuring efficiency and convenience.

Moreover, the REG-71A and REG-123A are equipped with advanced air filtration systems. These systems help to purify the air, reducing allergens and pollutants, which is especially beneficial for individuals with respiratory sensitivities.

The sleek and modern design of both units makes them a stylish addition to any living or working space. They are available in various capacities to cater to different room sizes, providing versatility for any installation requirement.

Furthermore, the units are designed for quiet operation, making them suitable for use in settings where noise levels need to be kept to a minimum, such as bedrooms and offices.

In summary, the Heat Controller REG-71A and REG-123A stand out for their innovative inverter technology, eco-friendly refrigerant, user-friendly features, advanced air filtration, and stylish design. These models provide a compelling option for anyone seeking efficient and reliable heating and cooling solutions.