Heat Controller REG-71A, REG-123A service manual Troubleshooting Guide, Unit runs but poor cooling

Page 24

Troubleshooting Guide

Troubleshooting Guide

In general, possible trouble is classified in two kinds.

The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and improper application.

Unit runs but poor cooling.

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (Heat exchanger)

Malfunction of fan

Clogged of air filter.

Obstruction at air outlet

Correct above trouble

Check clogging in refrigera- tion circuit.

Repair clogging in refrigera- tion circuit.

Check outdoor coil

(heat exchanger) & the fan operation.

Check gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air ; 44~50°F(7~10°C)

Check heat load increase.

Clean condenser.

Not on separate circuit.

Check inside gas pressure.

Adjusting of refrigerant charged.

Malfunction of compressor.

Replacement of compressor.

24Room Air Conditioner

Image 24
Contents +$7&21752//5,1& Table of Contents Safety Precautions Be sure not to do Be sure to follow the instructionThere is risk or fire or electric shock Dimensions Symbols Used in this ManualOutside Dimensions Product Specifications ItemsInstallation Installation CheckSelect the Best Location OptionalHow to InstallModels without Installation Kit How to InstallModels with Installaion Kit When Using Gasket REG-123AWhen Using Installation Kits REG-71A Cabinet Installation Suggested Tool RequirementsPreparation of Chassis Indoor Slide the unit into the cabinet.See Fig Features OperationControl Locations Function of Controls Disassembly Mechanical PartsFront Grille CabinetAir Handling Parts Air Guide and Turbo FanFAN Electrical Parts ShroudOverload Protector CompressorPower Cord CapacitorThermistor Refrigerating Cycle MotorEvaporator Capillary Tube Pulling Vacuum Schematic Diagram Wiring DiagramTroubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Room Air Conditioner Voltage Limits Complaint Cause RemedyTroubleshooting Guide +$7&21752//5,1&

REG-123A, REG-71A specifications

The Heat Controller REG-71A and REG-123A are innovative climate control units designed to provide efficient heating and cooling solutions for residential and commercial spaces. These models are characterized by advanced technologies that enhance energy efficiency, user comfort, and operational convenience.

One of the standout features of the REG-71A and REG-123A is their inverter technology. This technology allows the units to adjust their cooling and heating output based on the real-time demand, resulting in reduced energy consumption. By maintaining the desired temperature with minimal fluctuations, these models not only save on energy bills but also create a more comfortable indoor environment.

Another critical characteristic of these heat controllers is their Eco-friendly refrigerant, R32. This refrigerant has a lower Global Warming Potential (GWP) compared to traditional refrigerants, making the REG-71A and REG-123A environmentally responsible choices. Users can enjoy climate control without compromising on sustainability.

The units are designed with a user-friendly interface, featuring an intuitive remote control that enables users to adjust temperature settings, fan speeds, and operating modes easily. Additionally, both models include a programmable timer that allows for automatic operation based on individual schedules, ensuring efficiency and convenience.

Moreover, the REG-71A and REG-123A are equipped with advanced air filtration systems. These systems help to purify the air, reducing allergens and pollutants, which is especially beneficial for individuals with respiratory sensitivities.

The sleek and modern design of both units makes them a stylish addition to any living or working space. They are available in various capacities to cater to different room sizes, providing versatility for any installation requirement.

Furthermore, the units are designed for quiet operation, making them suitable for use in settings where noise levels need to be kept to a minimum, such as bedrooms and offices.

In summary, the Heat Controller REG-71A and REG-123A stand out for their innovative inverter technology, eco-friendly refrigerant, user-friendly features, advanced air filtration, and stylish design. These models provide a compelling option for anyone seeking efficient and reliable heating and cooling solutions.