Heat Controller REG-123A, REG-71A Select the Best Location, Installation Check, Optional

Page 7

Installation

Installation

SelecttheBest Location

1.To prevent vibration and noise, make sure the unit is installed securely and firmly.

2.Install the unit where the sunlight does not shine directly on the unit.

3.The outside of the cabinet must extend outward for at least 12" and there should be no obstacles, such as a fence or wall, within 20" from the back of the cabinet because it will prevent heat radiation of the condenser. Restriction of outside air will greatly reduce the cooling efficiency of the air conditioner.

CAUTION: All side louvers of the cabinet must remain exposed to the outside of the structure.

COOLED AIR

30"~60"

AWNING FENCE

HEAT

RADIATION

ABOUT 1/2"

Over 20"

Figure 1

4.Install the unit a little slanted so the back is slightly lower than the front (about 1/2 "). This will help force condensed water to the outside.

5.Install the unit from the bottom about 30"~60" above the floor level.

Installation Check

The setting conditions must be checked prior to initial starting.

The following items are especially important checking points when the installation is finished.

1.Grounding wire (Green or Green and Yellow) is provided in the power cord. The green wire must be grounded.

2.Connect to a single-outlet 15A circuit. (or 20A circuit for Electric Heater Model)

3.To avoid vibration or noise, make sure the air conditioner is installed securely.

4 Avoid placing furniture or draperies in front of the air inlet and outlet.

How to Secure the Drain Pipe(When using drain pipe)

 

In humid weather, excess water may cause the BASE PAN to overflow. To drain

 

 

the water, remove the DRAIN CAP and secure the DRAIN PIPE to the rear hole of

Drain pipe

 

the BASE PAN. Press the drain pipe into the hole by pushing down and away from

 

the fins to avoid injury.

 

Drain cap

Optional

 

 

1. Install the drain pan over the corner of the cabinet where you removed the

CABINET

SCREW

plug with 4 (or 2) screws.

 

 

2. Connect the drain hose to the outlet located at the bottom of the drain pan.

DRAIN

Fig. 1

You can purchase the drain hose or tubing locally to satisfy your particular

DRAIN HOSE

PAN

needs. (Drain hose is not supplied).

 

 

 

3. Select the most appropriate connection from among the following figures (by

 

considering the hole of the unit) to fit drain pan to your own unit.

 

Fig. 3

Fig. 2

Fig. 4

Service Manual 7

Image 7
Contents +$7&21752//5,1& Table of Contents Be sure not to do Be sure to follow the instruction Safety PrecautionsThere is risk or fire or electric shock Symbols Used in this Manual DimensionsOutside Dimensions Items Product SpecificationsOptional InstallationInstallation Check Select the Best LocationHow to InstallModels without Installation Kit When Using Gasket REG-123A How to InstallModels with Installaion KitWhen Using Installation Kits REG-71A Suggested Tool Requirements Cabinet InstallationPreparation of Chassis Indoor Slide the unit into the cabinet.See Fig Operation FeaturesControl Locations Function of Controls Cabinet DisassemblyMechanical Parts Front GrilleAir Guide and Turbo Fan Air Handling PartsFAN Compressor Electrical PartsShroud Overload ProtectorCapacitor Power CordThermistor Motor Refrigerating CycleEvaporator Capillary Tube Pulling Vacuum Wiring Diagram Schematic DiagramPiping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Complaint Cause Remedy Room Air Conditioner Voltage LimitsTroubleshooting Guide +$7&21752//5,1&

REG-123A, REG-71A specifications

The Heat Controller REG-71A and REG-123A are innovative climate control units designed to provide efficient heating and cooling solutions for residential and commercial spaces. These models are characterized by advanced technologies that enhance energy efficiency, user comfort, and operational convenience.

One of the standout features of the REG-71A and REG-123A is their inverter technology. This technology allows the units to adjust their cooling and heating output based on the real-time demand, resulting in reduced energy consumption. By maintaining the desired temperature with minimal fluctuations, these models not only save on energy bills but also create a more comfortable indoor environment.

Another critical characteristic of these heat controllers is their Eco-friendly refrigerant, R32. This refrigerant has a lower Global Warming Potential (GWP) compared to traditional refrigerants, making the REG-71A and REG-123A environmentally responsible choices. Users can enjoy climate control without compromising on sustainability.

The units are designed with a user-friendly interface, featuring an intuitive remote control that enables users to adjust temperature settings, fan speeds, and operating modes easily. Additionally, both models include a programmable timer that allows for automatic operation based on individual schedules, ensuring efficiency and convenience.

Moreover, the REG-71A and REG-123A are equipped with advanced air filtration systems. These systems help to purify the air, reducing allergens and pollutants, which is especially beneficial for individuals with respiratory sensitivities.

The sleek and modern design of both units makes them a stylish addition to any living or working space. They are available in various capacities to cater to different room sizes, providing versatility for any installation requirement.

Furthermore, the units are designed for quiet operation, making them suitable for use in settings where noise levels need to be kept to a minimum, such as bedrooms and offices.

In summary, the Heat Controller REG-71A and REG-123A stand out for their innovative inverter technology, eco-friendly refrigerant, user-friendly features, advanced air filtration, and stylish design. These models provide a compelling option for anyone seeking efficient and reliable heating and cooling solutions.