Haier HSM24HEK03/R2(DB), AS18GS1ERA Base Operation Emergency operation and test operation

Page 3

Operation

Base Operation

Emergency operation and test operation

Emergency Operation:

Remote controller

2

TURBO/QUIET

 

 

 

 

 

 

11

 

 

 

3

SWING

 

 

4

 

 

 

 

 

3

2

HEALTH

SLEEP

 

TIME

TIME

 

 

ON

OFF

 

 

Use this operation only when the remote controller is defective

or lost, and with function of emergency running, air conditoner

can run automatically for a while.

 

When the emergency operation switch is pressed, the " Pi "

sound is heard once, which means the start of this operation.

When power switch is turning on for the first time and

emergency operation starts, the unit will run automatically in

the following modes:

 

 

Pi

Room

Designated

Timer

Fan

Operation

temperature

temperature

mode

speed

mode

Above 23oC

26oC

No

AUTO

COOL

It is impossible to change the settings of temp. and fan speed,It

1. Unit start

Press ON/OFF on the remote controller, unit starts.

2.Select operation mode

COOL button:Cooling mode FAN button: Faning mode DRY button: Dehumidify mode

3.Select temp.setting

Press

/

button

 

Every time the button is pressed, temp.setting

 

increase 1oC,if kept depressed, it will increase

 

rapidly

 

 

Every time the button is pressed, temp.setting

 

decrease 1oC,if kept depressed, it will

 

decrease

rapidly

Select a desired temperature.

4.Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

Display circulated

LOW MED

HI

AUTO

Air conditioner is running under displayed fan speed. When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.

Operation

Remote

Note

Mode

Controller

 

 

 

Under the mode of auto operation, air conditioner will

AUTO

 

automatically select Cool or Heat operation according to

 

room temperature. When FAN is set to AUTO the air

 

 

conditioner automatically adjusts the fan speed according

 

 

to room temperature.

COOL

 

according to room temperature.

DRY

 

In DRY mode , when room temperature becomes lower

 

than temp.setting+2o C, unit will run intermittently at LOW

 

 

speed regardless of FAN setting.

 

 

In FAN operation mode , the unit will not operate in COOL or

FAN

 

HEAT mode but only in FAN mode, AUTO is not available in

 

FAN mode. And temp. setting is disabled. In FAN mode,

 

 

sleep operation is not available.

is also not possible to operate in timer or dry mode.

Test operation:

Test operation switch is the same as emergency switch.

Use this switch in the test operation when the room

temperature is below 16oC, do not use it in the

normal operation.

Pi Pi

 

Continue to press the test operation

switch for more than 5 seconds . After you hear the "Pi" sound twice, release your finger from the switch: the cooling operation starts with the air flow speed "Hi".

Under this operation mode,the fan motor of indoor unit will run in high speed.

Air Flow Direction Adjustment

1.Status display of air flow

Vertical flap

Pos.1

(Auto swing)

Initial state

Pos.2 No initial state disaplayed on remote controller, the vertical flap will be fixed on the current position

2.Left and right air flow adjustment

For each press of button, remote controller displays as follows :

remote controller:

Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

Pos.6

 

 

Cautions:

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur adjusted to left or at air outlet if all vertical louvers are right.

It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY mode , otherwise, condensate water might occur.

Note:

When restart after remote turning off, the remote controller controller will automatically memorize the previous set swing position.

3

Image 3
Contents 0010564364 Display board Loading of the batteryIndoor Unit Remote controller Parts and FunctionsAir Flow Direction Adjustment OperationBase Operation Emergency operation and test operation COOL, DRY mode Operation Mode COOL,DRY modeHigher than temp.setting.After another 1 hours,temp.rises When running in Turbo,the fan speed is the highestPress to starting Timer On/Off On-Off OperationSetting the comfort work conditions Health airflow OperationFor Smart Use of The Air Conditioner MaintenanceReplacement of Air Purifying Filter Use the timer effectivelyInstallation Check properDrainage securely Trouble shooting SpecificationsMachine is adaptive in following situation

HSU-18LEK03/R2(DB), HSU-10VEK03, HSU-15LQA13, HSU-12LEK03/R2(DB), HSU-12LQA13/R2(DB)-WT specifications

Haier is known for delivering innovative cooling solutions, and its range of air conditioners showcases a commitment to efficiency, performance, and user comfort. Among these, the Haier AS18GS1ERA, HSM24HEK03/R2(DB), AS12GS1ERA, HSU-09LQA13/R2(DB)-BK, and HSU-12LQA13/R2(DB)-BK stand out for their advanced features and cutting-edge technologies tailored to meet diverse household needs.

Starting with the Haier AS18GS1ERA, this unit offers a cooling capacity suitable for larger spaces while maintaining energy efficiency. Equipped with inverter technology, it adjusts its compressor speed according to the cooling demand, leading to lower energy consumption and quieter operation. Additionally, the AS18GS1ERA incorporates a self-cleaning function that prevents dust and mildew build-up, ensuring the air remains fresh and healthy.

The HSM24HEK03/R2(DB) is designed for high-capacity performance, suitable for both residential and commercial spaces. Its dual inverter technology minimizes energy costs while providing effective cooling across varying temperature conditions. This model features a modern design with a sleek finish, making it a seamless fit for any décor. An intelligent temperature control system enhances user comfort by maintaining stable indoor temperatures.

The Haier AS12GS1ERA offers versatility and efficiency in a compact package, perfect for medium-sized rooms. It includes features such as a high-efficiency air filter that captures allergens and pollutants, ensuring clean air circulation. Moreover, its eco-friendly refrigerant contributes to a lower environmental impact, aligning with contemporary sustainability goals.

For those seeking innovative solutions, the HSU-09LQA13/R2(DB)-BK and HSU-12LQA13/R2(DB)-BK models promise exceptional performance and style. Both units utilize DC inverter technology, allowing for precise temperature control and reduced noise levels. Their elegant design features a black finish that adds a contemporary touch to any living space.

Each of these Haier models boasts user-friendly interfaces and smart features, including remote control options and energy-saving modes. They are equipped with advanced safety mechanisms, ensuring reliable and safe operation throughout their lifespan. In conclusion, Haier's air conditioning units not only provide exceptional cooling performance but also prioritize energy efficiency and user comfort, making them an ideal choice for modern households.